Range of four-hole, single outlet (fixed) combination tap assemblies (various finishes). Incorporating quarter turn ceramic disc headworks, with various operating members. interconnecting flexible hoses. The spout outlets incorporate a self-cancelling diverter to the shower outlet and a plastic flow straightener with a stainless-steel mesh strainer. The product is supplied with a shower handset that incorporates a single check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of four-hole, single outlet (fixed) combination tap assemblies (various finishes). Incorporating quarter turn ceramic disc headworks, with various operating members. interconnecting flexible hoses. The spout outlets incorporate a self-cancelling diverter to shower outlet and a plastic flow straightener with stainless steel mesh. The product is supplied with a shower handset that incorporates a single check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
A range of four-hole single outlet fixed combination tap assemblies with brass bodies in a variety of finishes (See models). Incorporating ¼ ceramic disc headworks with single lever operating members and a self-cancelling diverter to a shower outlet. The spout outlet incorporates a plastic aerator. The shower outlet elbow incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. This product is supplied with a shower hose, shower handset and metal screw clamp type back nuts. The side valves and the spout are connected with a copper tube. Maximum working pressure 10 bar. Maximum working temperature 60 °C.
Range of floor mounted, single hole, single outlet fixed combination tap assemblies (chromium plated brass with a self-cancelling diverter to shower outlet. The product incorporates a ceramic cartridge headwork and single lever operating member. The spout outlets incorporate an aerator and the product is supplied with a hose and handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall elbows incorporating brass bodies (various finishes) and various back plates. Maximum operating temperature 95ºC.
ERA-01 range of SDR11 and SDR17 polyethylene butt welded fittings for use with ERA-02 range of SDR11 and SDR17 PE 100 pipe. SDR11 rated pipe and fittings have a maximum working pressure of 16.0 bar. SDR17 rated pipe and fittings have a maximum working pressure of 10.0 bar. For above and below ground use. Cold water use only.
Range of copper press fittings with EPDM seals for use with EN1057 copper tube. The joints are achieved by means of a press tool. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of press-fit end connectors (gunmetal bodies) for use with copper pipe manufactured to BS EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of brass tee fittings for use with copper pipe to EN1057. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of end feed copper solder fittings for use with copper tube. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Low profile mechanical seal intended for the internal repair of pipe joints. The system incorporates two stainless steel compression rings and an EPDM seal. For above and below ground use. Maximum working pressure 22.5 bar. Cold water use only.
OMEG range of wall mounted, near-boiling water dispensers (cased and insulated). The products incorporate a solenoid valve which controls the flow, a stainless-steel tank, 3 or 5L (see model), and a plastic strainer at the inlet. Maximum supply pressure 10.0 bar. Cold water supply only. Maximum operating temperature 95˚C
Range of floor standing gas fired combination boilers providing domestic hot water via a stainless-steel plate heat exchanger. Unit is supplied with a safety relief valve (8.0 bar). Maximum working pressure 7.5 bar. Maximum operating temperature 85°C.
Aquila V5 range of water meters with black epoxy coated cast iron bodies, plastic turbines, fibre/NBR flange gaskets and either NBR or EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Cold water use only.
Range of ultrasonic water meters with brass bodies incorporating EPDM ‘O’-rings. The inlets incorporate a plastic strainer. The DN15 X 165mm and DN20 X 190mm models incorporate a non-return valve on the outlet. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of water meters with a brass body, EPDM ‘O’-rings and seal. The products incorporate an internal plastic strainer and an optional combined plastic and stainless-steel strainer on the inlet. Maximum working pressure 16.0 bar. Cold water use only
Range of water meters with blue epoxy coated iron bodies and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of single-jet water meters with brass bodies and a plastic strainer on the inlet. Maximum working pressure 16.0 bar. Maximum operating temperature 90°C.
MJ (Multi jet) range of water meters with either ductile iron (MJF model) or brass (MJ models) blue epoxy coated bodies and EPDM rubber ‘O’-rings. Maximum working pressure16.0 bar. Maximum operating temperature 85°C.
Range of ‘Resident Valves’ with a DZR brass body consisting of water meter manifold, an isolation valve on the inlet, a pressure reducing valve (adjustable between 1.5 and 6.0 bar) and 2 non-return valves which are located on the outlet of the water meter manifold. The ‘Plus’ models are also supplied with an isolation valve on the outlet, which incorporates a drain tap. Maximum supply pressure 16.0 Bar. Cold water above ground use only.
Page 110 of 578
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.