Section Code 1180 : Couplings. Unless specified in the individual approval, the products within this section are not suitable for below ground use
Back To Directory SectionsAquaflow range of polypropolene fittings for use with PE pipe (manufactured to EN 12201). Maximum working pressure 16 bar. Cold water use.
Range of black polyethylene electrofusion fittings for use with PE100 pipe (manufactured to EN 12201-2). Please refer to model for maximum working pressures. For below ground and cold water use only.
Range of tank and cistern connectors, with push fittings. Models CM0715S and CM0722S are for use with copper tube (manufactured to BS EN 1057) PE-X pipe (BS7291-3) & PB pipe (BS7291-2). Until April 2023, model CM0728S was only for use with copper tube (manufactured to BS EN 1057). From May 2023, model CM0728S is also for use with PE-X pipe (BS7291-3) & PB pipe (BS7291-2). Cold water use only.
Range of ‘Superseal’ and ‘Speedfit’ push-fit fittings with acetal body’s (black or light grey) and NBR ‘O’ rings. For use with John Guest LLDPE tubing (Speedfit port only) and 316 stainless steel tubing manufactured to EN10088 (Superseal push-fit port only). Pipe inserts must be used for the LLDPE tube sizes 3/8” and ½”. Maximum working pressure: See models below. For cold water use only.
Range of press-fit fittings with stainless steel bodies incorporating EPDM ‘O’-rings for use with SS316L pipes. Maximum working pressure 16 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of plastic push-fit fittings (available in black, white and grey) and a manifold (available in grey only) with EPDM or NBR ‘O’-rings. For use with copper pipe (manufactured to EN1057), PE-X pipe (manufactured to BS7291-3:2010) & PB pipe (BS EN 21003-2:2008). Maximum working pressure: 12.5 bar @ 20°C (Cold water use only). From September 2023 the products are suitable for 8.0 bar @ 65°C.
Range of compression fittings with brass bodies for use with copper pipe (EN1057). Above ground use only. Maximum working pressure 16 bar. Maximum operating temperature 85°C.
Range of “Effast” ABS fittings for use with ABS pipe complying with BS EN 5391-2006. Maximum working pressure: 15 Bar. Maximum operating temperature: 23°C.
Range of DZR brass push fit fittings for use with copper pipe (manufactured to BS EN 1057), PB pipe (manufactured to BS7291-2) and PEX pipe (manufactured to BS7291-3). Maximum working pressures and operating temperatures: 12.5 @ 20°C, and 3.0 bar @ 92ºC.
Range of press fittings with a stainless steel body and EPDM ‘O’ rings for use with stainless steel 316L pipe manufactured to EN10312. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
alpex Duo XS and alpex L (PPSU & Brass) ranges of press fittings for use with alpex Duo XS (F and TH press profiles) & alpex L pipe (F press profile only). Maximum working pressure 10.0 bar. The maximum operating temperature is 95oC.
PLAS-FIT range of polypropolene fittings for use with PE pipe (manufactured to EN 12201). Maximum working pressure 16 bar. Cold water use.
Range of Conex >B< press fittings incorporating copper & brass bodies for use with copper tube (manufactured to EN1057). Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
‘Trustlene’ range of electrofusion and spigot fittings, with PE100 or brass bodies, for use with SDR11 PE100 pipe (manufactured to IS 4984: 2016). For use above and below ground. Maximum working pressure 16.0 bar. Cold water use only.
Range of Effast PVC-u solvent welded and/or threaded fittings for use with PVC-u pipe manufactured to (EN1452-2). Maximum working pressure 16.0 bar. Cold water use only.
Stainless steel press fittings incorporating EPDM ‘O’-rings for above ground use only. To be used with stainless steel 316L pipe (EN 10312). Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of Talbot pushfit fittings with polyprolylene or acetal bodies and EPDM o-rings for use with MDPE PE80 pipe (BS EN 12201). For use above and below ground use. Maximum working pressure 16 bar. Cold water use only.
JG Speedfit range of push-fit fittings and manifolds for use with Polybutylene Barrier Pipe (manufactured to BS EN 7291-2:2010 ) and PEX Barrier Pipe (manufactured to BS EN 7291-3:2010) and Copper Pipe (manufactured to BS EN1057:). Operating parameters: 12.5 bar@20°C.
‘AquaGas M range’ of copper and brass press fit fittings with NBR ‘O’-rings for use with copper tube (manufactured to BS EN 1057). Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
‘SharkBite’ range of brass push fit fittings incorporating an EPDM ‘O’-ring. For use with the following pipes: JG Speedfit Layflat Polybutylene Barrier Pipe (JG BPB pipe manufactured to BS EN 7291-2:2010), 'BPEX' Barrier Pipe (JG BPEX pipe manufactured to BS EN 7291-3:2010), Polybutylene barrier pipe (manufactured to BS EN 7291-2:2010), PEX barrier pipe (manufactured to BS EN 7291-3:2010) and Copper pipe (manufactured to BS EN1057:2006). Maximum working pressures and operating temperatures: When used with Polybutylene barrier pipes (manufactured to BS EN 7291-2:2010) and PEX barrier pipes (manufactured to BS EN 7291-3:2010): 12.5 bar, cold water use only. 6.0 bar @ 95°C. When used with copper pipe (manufactured to BS EN1057:2006): 10mm sizes: Maximum working pressure 16.0 bar. Cold water use only. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C. 15-22mm sizes: Maximum working pressure 20.0 bar. Cold water use only. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C. 28mm size added April 2024: Maximum working pressure 20.0 bar. Cold water use only. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
Range of Redman fittings with mild steel bodies (polyamide coating) for use with Puriton II PE-AL-PE barrier pipe - For above and below ground and cold-water use. Jointing is achieved by hydraulic compression. Maximum working pressures: 12.5 Bar for 63mm SDR 11 PE80 pipe system, 10.0 Bar for 90mm to 180mm SDR 17 PE100 pipe system, 16.0 bar for 90mm to 180mm SDR 11 PE100 pipe system. Cold water use only.
IDC ‘BDGxxx’ range of press fittings with brass or nickel plated brass bodies (see model) incorporating EPDM ‘O’-rings and stainless steel crimp sleeves for use with PEX/AL/PEX multilayer pipe (manufactured to EN ISO 21003). The BDG241 and BDG257 prefix models incorporate an EPDM gasket on the captive nut end connection. Pressfit jointing is achieved by either a U or TH crimping profile. Compression connections are for use with copper pipe 12-28mm (manufactured to EN1057) or Irish copper pipe 14.7-27.4mm (manufactured to EN1057). For above ground use only. Maximum working pressure 10.0 bar. 20, 25 & 26mm pressfit sizes cold water use only. Threaded, compression and 16 & 32mm pressfit sizes maximum operating temperature 95°C.
MecFlow Press (PPSU & Brass) Ranges of press fittings for use with MecFlow Press pipes. Maximum working pressure 10.0 bar. The maximum operating temperature is 95oC.
"Yi Sin" Range of press fittings with a stainless steel body and EPDM ‘O’ rings for use with stainless steel 316L pipe manufactured to EN10312. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Universal plastic compression adaptor kits for use with SAB A16 fitting body (not included as part of this approval) and galvanised steel pipe (manufactured to EN 10255). Maximum working pressure 16 bar. Cold water use only.
Range of M profile brass press fittings with EPDM ‘O’-rings or gaskets to be used with copper pipe manufactured to EN1057 for above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of ‘Isiflo Sprint’ push fit fittings for use with PE100 pipe (manufactured in accordance with EN 12201), for above and below ground use. Isiflo Sprint Family fittings can be installed with seal liners, support liners and without any liner. Maximum working pressure 16 bar. Cold water use only.
SANHA Press Series 6000 & 16000 and PURAPRESS Series 8000 of press-fit fittings with copper (6000), bronze (8000) and chrome plated copper (16000) bodies and EPDM `O`-rings. For use with copper pipe manufactured in accordance with BS EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of press fittings with a stainless steel body and EPDM ‘O’ rings for use with stainless steel 316L pipe manufactured to EN10312. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of M profile press fit fittings with a brass body and NBR O-rings, for use with copper pipe manufactured to EN1057 and stainless-steel pipe manufactured to EN10312. Maximum working pressure: 10 Bar. Maximum operating temperature: 85°C.
‘Tectite 316’ range of push-fit fittings with stainless steel bodies incorporating EPDM ‘O’-rings for use with stainless steel tube (Grade 316 manufactured to EN 10312). Maximum working pressure: Fittings 15mm to 28mm 10.0 bar. Fittings 35mm to 54mm 6.0 bar. Maximum operating temperature 90°C.
Range of compression fitting with brass and DZR brass bodies, supplied with brass compression rings. For use with copper tube (manufactured to BS EN1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of ‘B’ Press XL copper crimped fittings with EPDM ‘O’-rings for use with copper pipe to BS EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of copper crimped fittings with EPDM ‘O’-rings for use with copper pipe manufactured to EN1057. For above and below ground use. Maximum working pressure 16 Bar. Maximum operating temperature 99°C.
B Profile range of 316L & 304 stainless steel press fittings with EPDM ‘O’-rings for use with stainless steel pipe manufactured to EN 10312, for both above and underground use. Joints are achieved by the use of a press fitting tool. Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C.
Range of R-154 stainless steel pressed collars incorporating stainless steel bodies (304L or 316L) and are only to be used with stainless steel pipe. Maximum working pressure for sizes up to DN150 (FCM models) or DN125 (FCI models) is 25.0 bar. Maximum working pressure for size DN200 (FCM models) or DN150 and DN200 (FCI models) is 16.0 bar. Maximum operating temperature 99°C.
Silicon Bronze bodies Press Fittings with EPDM `O`-rings. For use with copper pipe manufactured in accordance with BS EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Copper press-fit fittings with copper with EPDM `O`-rings. For use with copper pipe manufactured in accordance with BS EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
FLOMASTA range of polypropolene fittings for use with PE pipe (manufactured to EN 12201). Maximum working pressure 16 bar. Cold water use.
Range of stainless steel press fittings: SS316L stainless steel models are for use with SS316L stainless steel pipe manufactured to EN 10312.; SS304 stainless steel models are for use with SS304 stainless steel pipe manufactured to EN 10312. Crimp joint is achieved by a M profile crimp jaws. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of stainless-steel press fittings (SUS304 or 316L) with EPDM ‘O’-rings for use with stainless-steel pipe (SUS304 or 316L EN 10312), using an ‘M’ press profile. Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C.
Range of copper crimped fittings with EPDM ‘O’-rings for use with copper pipe manufactured to EN1057. For above and below ground use. Maximum working pressure 16 Bar. Maximum operating temperature 99°C.
DMFit range of black and grey plastic pushfit fittings for use with DM LLDPE pipes. Supplied with black pipe inserts and metric PEX barrier pipe manufactured to BS7291-2. Supplied with grey pipe inserts. LLDPE pipes are available in black, natural (appearance is white), white, red, and blue colours. Metric sizes - 4, 5, 6, 8, 10, 12mm for use with LLDPE (white, black, red, blue & natural) tubing only. Metric size - 15mm for use with LLDPE tubing (white, black, red, blue & natural) Imperial sizes - 5/32”, 3/16”, ¼”, 5/16”, ⅜”, ½” & ¾” for use with LLDPE tubing (white, black, red, blue & natural). Maximum working pressure: 12.0 bar. Cold water use only. Maximum working pressure: 7.0 bar. Maximum operating temperature: 65°C.
“<A> Press Copper M Profile” series press fittings with a copper body and EPDM ‘O’-rings, for use with copper pipe manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Press-Inox range of stainless-steel crimped fittings (‘M’ crimp profile) for use with stainless steel pipe (manufactured to EN10204). For above ground use only. Maximum working pressure: 16Bar. Maximum operating temperature: 100°C.
Range of brass (CW617 or CW511L) press fit fittings (M-Type) for use with copper pipe manufactured to EN 1057. Maximum working pressure: 16 Bar. Maximum operating temperature: 99°C.
Tectite Classic and Tectite Pro ranges of copper alloy push-fit fittings The Tectite Classic range is for use with copper tube (manufactured to BS EN 1057) and PEX & Polybutylene tube (manufactured to BS 7291). The fittings are supplied with plastic inserts. The Tectite Pro range is for use with copper tube (manufactured to BS EN 1057). Maximum working pressures & operating temperatures: Tectite Classic fittings with copper pipe: 6.0 bar @ 95°C, 16.0 Bar cold water use. Tectite Classic fittings with PEX & Polybutylene 6.0 bar @ 95°C, 12.0 Bar cold water use. Tectite Pro fittings (15mm - 28mm): 6.0 bar @ 95°C, 20.0 Bar cold water use. Tectite Pro fittings (32mm - 54mm): 6.0 bar @ 95°C, 16.0 Bar cold water use.
Range of stainless steel (SS316L) pressfit fittings with EPDM ‘O’-rings for use with stainless steel pipe (manufactured to EN10312). Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of plastic, push-fit fittings (wall plate elbow, equal elbow, end stop, pipe insert, equal straight and equal tee) for use with MDPE pipe (manufactured to BS EN 12201), for above and below ground use. Copper adaptors are for use with PB pipe (manufactured to BS7291-2), PEX pipe (manufactured to BS7291-3) or Copper pipes (manufactured to BS EN 1057) and are for above ground use only. Maximum working pressure 16.0 bar. Cold water use only.
‘Universal Transition Coupling (UTC)’ range of plastic compression fittings for use with the following pipe types and sizes: Stainless steel (manufactured to ASTM A554/ BS EN 10312): ¾”, 1” & 1¼”. Galvanised (EN 10255): ¾”, 1”, 1¼”, 1½” & 2”. Copper (BS EN 1057): 15mm, 22mm & 28mm. PVC (BS EN 1452): 20mm & 2”. ABS (BS 5391-1): 20mm, 25mm & 32mm. PE80 & PE100 pipe (to BS EN 12201): 20mm, 25mm, 32mm, 50mm & 63mm. For use above and below ground. Maximum working pressure 12.5 bar. Cold water use only.
Page 2 of 3
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.