Range of end feed copper fittings for use with copper tube to EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘Jet 806’ range of pre-set pressure relief valves incorporating gunmetal bodies, PTFE seat and lever operated easing gear. Each valve is available with a pre-set rating of between 1.0 bar and 12.5 bar, in increments of 0.1 bar. Maximum operating temperature 95˚C.
Two hole, single outlet (fixed) combination tap assembly (chrome plated brass body), Incorporating non-rising spindle headworks with dome type top operating members. The product incorporates a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose, handset and metal backnuts. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 70°C
Range of two-hole, single outlet (fixed) combination tap assemblies (chrome plated brass bodies) incorporating quarter turn ceramic disc headworks with dome type operating members and a manually operated diverter to the shower outlet. The spout outlets incorporate plastic flow straighteners. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Dual flush, WC outlet valves. The valves are operated via a push button assembly for either full or reduced flush and incorporate an internal overflow. Cold water use only.
Range of stainless-steel braided EPDM lined flexible hose assemblies with a variety of end connections. Some models incorporate screwdriver operated isolation valves. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
'571983 & 571984'. White coloured (semi-translucent), extruded PTFE tape. For use with water up to 85°C.
Range of shower rail kits, (chrome plated - plastic bodies) incorporating a shower handset, shower hose and adjustable shower rail. Maximum operating temperature 80°C. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 80°C
Side entry BS1212-4 fill valves with plastic bodies. Maximum working pressure 10.0 bar. Coldwater use only.
Range of bottom entry BS1212-4 telescopic fill valves with plastic bodies. Maximum working pressure 10.0 bar. Cold water use only.
Range of copper or brass (see model) end feed fittings for use with copper tube (manufactured to BS EN1057). Tap connectors incorporate Fibre/NBR washers. Male and female union adaptors incorporate a silicone gasket. Maximum working pressure using hard solder: 8mm to 28mm, ½” to 1” BSP (F) or (M), 1” straight cylinder union and captive nut ½” to ¾”: 25.0 bar, 35mm to 54mm, 1¼” to 2” BSP (F) or (M): 16.0 bar. Maximum working pressure using silver brazing alloy EN1044: 66.7mm to 108mm, 2½” to 4” BSP (F) or (M): 16.0 bar, 133mm to 219mm: 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of single hole, single outlet (swivel) combination tap assemblies (brass bodies – various finishes), incorporating ceramic disc headworks with single lever operating members (see models). The inlets incorporate stainless steel strainers. The spout outlets incorporate a plastic aerator or a flow straightener. Maximum working pressure 10 Bar. Maximum operating temperature 65 °C.
Range of stainless steel, stainless steel with nylon or nylon braided, EPDM lined hose assemblies. Some models incorporate servicing valves. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of handwheel operated gate valves with brass bodies, gate & PTFE seals, for use with copper tube manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of quarter turn, lever handle operated spherical valves with nickel plated brass bodies, chrome plated brass balls and PTFE seals. For use with copper pipe BS EN 1057. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of manually operated dual flush WC outlet valves. Cold water use only.
Range of single hole, single outlet (fixed) electronically controlled tap assemblies, (Chrome plated - brass bodies). Flow is controlled by a solenoid valve activated by via an infra-red sensor. The spout outlets incorporate plastic aerators. Maximum working pressure 10 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet, (swivel), combination tap assemblies (chromium plated brass bodies), incorporating quarter turn ceramic disc headworks and single lever operating members. The outlet is a pull down spray type and incorporates a plastic aerator. Maximum working pressure 10 bar. Maximum operating temperature 65°C
Single hole, single outlet (swivel) combination tap assemblies (chromium plated brass body), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporate a plastic flow straightener or plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 65˚C.
Range of wall mounted, thermostatic bar shower mixer (chrome plated brass body), incorporating a quarter turn ceramic disc headwork that controls the flow with a dome operating member. Temperature is controlled independently via a thermostatic cartridge with dome type operating member that incorporates a manual override button. Both inlets incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. This product is supplied with an overhead shower, handset, shower hose and a riser rail assembly that incorporates a manual diverter that controls flow from overhead shower and shower handset. Maximum working pressure 5.0 bar
Non-metallic materials and components comply with BS6920 at 60°C
Page 3 of 7
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.