Directory Search Results

Print List

#240504020

Range of angled valves with brass bodies (some models chrome plated). Maximum working pressure 10 bar. Maximum operating temperature 65°C

Section:
2310 Valves
Section Subtitle:
Stop, metal, screw down.
WRAS Approval Number:
240504020
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
see models
Marking:
Schell moulded on to Valve Body
Installation Requirements:
R001
Expiry date:
31/05/2029
Model:
05 112 - ½” BSP (M) x ⅜” BSP (M) 05 252 - ½” BSP (M) x 10mm compression 05 377 - ½” BSP (M) x ½” BSP (M) 05 257 - ½” BSP (M) x ⅜” BSP (M) 05 396 - ½” BSP (M) x ½” BSP (M) 05 398 - ½” BSP (M) x ½” BSP (M) 05 399 - ½” BSP (M) x ½” BSP (M) 05 414 - ½” BSP (M) x ⅜” BSP (M) 05 415 - ½” BSP (M) x ⅜” BSP (M) 05 419 - ½” BSP (M) x ½” BSP (M) Models added January 2025: 05 212 - ½” BSP (M) x ⅜” BSP (M) 05 217 - ½” BSP (M) x ½” BSP (M) 05 430 - ½” BSP (M) x ⅜” BSP (M) with filter
Product Images

Approval Holder:
Schell GmbH & Co KG Armaturentechnologie
Company Name
Schell GmbH & Co KG Armaturentechnologie
Address
Raiffeisenstrasse 31 Olpe
Postcode
D-57462
Country
Germany
Phone
+492761892294
General Email
info@schell.eu

View All Listings by this Company
Manufacturer:
Schell GmbH & Co KG Armaturentechnologie
Company Name
Schell GmbH & Co KG Armaturentechnologie
Address
Raiffeisenstrasse 31 Olpe
Postcode
D-57462
Country
Germany
Phone
+492761892294
General Email
info@schell.eu

View All Listings by this Company

Print This Approval


#241204702

‘Satefy group’ with a brass inlet and a DZR brass body which incorporates a lever operated spherical valve, followed by an approved check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) and a plastic bodied pressure relief valve (set at 6.0 bar). The product incorporates a test point. The compression connections are for use copper pipe (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
2345 Valves
Section Subtitle:
Special combination assemblies.
WRAS Approval Number:
241204702
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
15mm compression
Marking:
Caleffi logo, DN15, CR mark and flow arrow cast on body. Date of manufacture WW/YY printed on body. Caleffi and Caleffi logo, flow arrow, CE marking on pressure relief valve body. 6 bar, size, EN1491 and other technical information on pressure relief valve operating gear
Installation Requirements:
R001 R008 R120
Expiry date:
31/12/2029
Model:
528716

Approval Holder:
Caleffi S.p.A
Company Name
Caleffi S.p.A
Address
Strada Regionale 229 n. 25 Fontaneto d'Agogna (NO)
Postcode
28010
Country
Italy
Phone
+39 0322 8491
General Email
gary.perry@caleffi.com

View All Listings by this Company
Manufacturer:
Caleffi S.p.A
Company Name
Caleffi S.p.A
Address
Strada Regionale 229 n. 25 Fontaneto d'Agogna (NO)
Postcode
28010
Country
Italy
Phone
+39 0322 8491
General Email
gary.perry@caleffi.com

View All Listings by this Company

Print This Approval


#240402710

Range of motorised position pilot operated control valves with epoxy coated ductile iron bodies and stainless-steel pipework and fittings. Maximum operating pressure 16.0 bar. Maximum operating temperature 65°C.

Section:
2347 Valves
Section Subtitle:
Special combination assemblies, pilot operated control.
WRAS Approval Number:
240402710
Size:
DN40 up to DN1400 flanged inlet and outlet.
Marking:
Cla-Val, flow arrow, DN, PN and model number on data plate on flange.
Installation Requirements:
R001
Expiry date:
30/04/2029
Model:
NG1E-138-L21KCOS (DN50 to DN600) 138-G1E-L21KCOS (DN40 to DN400) NG1E-138-L721KCOS TYTAN S (DN600 to DN800) NG1E-138-L721KCOS TYTAN M (DN900 to DN1000) NG1E-138-L721KCOS TYTAN L (DN1200 to DN1400) All valves up to DN600 have the option to be fitted with a manual operator. For sizes above 600mm, this is fitted as standard. Description of suffix codes, where: ‘K’ = Generic prefix for any subsequent letters ‘C’ = Internally and Externally epoxy coated ‘O’ = Stainless steel studs and washers for the main valve ‘S’ = Stainless steel seat and Disc guides
Product Images

Approval Holder:
Cla-Val UK Ltd.
Company Name
Cla-Val UK Ltd.
Address
Dainton House 107 Goods Station Road Tunbridge Wells
Postcode
TN1 2DR
Country
United Kingdom
Phone
01892 514400
General Email
liam.kent@cla-val.co.uk

View All Listings by this Company

Print This Approval


#240402704

Range of ultraviolet disinfection units with stainless-steel bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 40°C.

Section:
2411 Disinfection Equipment
Size:
DN25 – DN150 Flanged
Marking:
LIFELINE UV on adhesive label on body.
Installation Requirements:
R001 R120 R150 R170 R290 R511
Expiry date:
30/04/2029
Model:
Lifeline UV 00149 B, RC and RCM Lifeline UV 00322 B, RC and RCM Lifeline UV 00729 B, RC and RCM Lifeline UV 01250 B, RC and RCM Lifeline UV 02300 B, RC and RCM Lifeline UV 04400 B, RC and RCM Lifeline UV 10020 RC and RCM
Product Images

Approval Holder:
Lifeline Products Ltd
Company Name
Lifeline Products Ltd
Address
Unit 19 Cheltenham Trade Park Cheltenham
Postcode
GL51 8LZ
Country
Gloucestershire

View All Listings by this Company

Print This Approval


#240502712

Range of UV disinfection units with stainless steel bodies. Maximum working pressure 10.3 bar. Maximum operating temperature 60°C.

Section:
2411 Disinfection Equipment
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Please refer to model.
Marking:
Luminor Rainier, model, WRAS and serial number on adhesive label on body
Installation Requirements:
R001 R150 R170
Expiry date:
31/05/2029
Model:
Single Lamp UV Disinfection Units: LRx-35X Rainier - 1½” NPT (M). LRx-55X Rainier - 2” NPT (M). LRx-85X Rainier - 2” NPT (M). Double Lamp UV Disinfection Units: LRx-110X Rainier - 2½” NPT (M). LRx-140X Rainier - 3” NPT (M). LRx-175X Rainier - 4” NPT (M). X denotes a UV sensor or a glow plug and is replaced with: 5= Glow Plug & 6 = UV Sensor. X denotes the type of power cord and is replaced with: 1 = NEMA 5/15. 2 = CEE 7/7. 3 = BS1363. 4 = AS/NZ 3112. 5 = NEMA 6/15. Additional Suffixes can be used for different lamps or sensor calibrations: HW, TOC or 50.
Product Images

Approval Holder:
Luminor Environmental Inc.
Company Name
Luminor Environmental Inc.
Address
80 Southgate Drive, Unit 4, Guelph, ON Guelph
Postcode
N1G 4P5
Country
Canada,

View All Listings by this Company

Print This Approval


#240455029

'Loctite PC 7255 GN (Green) coating for use with Bonderite M-NT 1455-W primer'. Factory applied, green coloured, two-component epoxy resin coating. Prime the surface to be coated with the Bonderite primer wipe. Mix and apply as per manufacturer’s TDS dated October 2016. Cure for 7 days@23°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.

Section:
5030 Coatings, Paints & Linings
Section Subtitle:
Factory applied pipe & fittings coatings.
WRAS Approval Number:
240455029
Expiry date:
30/04/2029

Approval Holder:
Henkel Ltd.
Company Name
Henkel Ltd.
Address
Technologies House, Wood Lane End, Hemel Hempstead
Postcode
HP2 4RQ
Country
Herts
Phone
+44 1442 278 100
General Email
loctite.connect@henkel.com

View All Listings by this Company

Print This Approval


#240555036

'Edelpoxy FN TM 142'. Factory coloured, red coloured epoxy resin coating consisting of a base and hardener. Mix base and hardener in a 3:1 volume ratio and apply as per manufacturer's IFU 'PCC/ PC 142', dated '10.07.2018'. Cure for 7 days@30°C. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.

Section:
5030 Coatings, Paints & Linings
Section Subtitle:
Factory applied pipe & fittings coatings.
WRAS Approval Number:
240555036
Expiry date:
31/05/2029

Approval Holder:
PC Chanda & Co. PVT Ltd.
Company Name
PC Chanda & Co. PVT Ltd.
Address
Ravi Auto House, 103 Park Street, 6th Floor, Kolkata 700016
Country
India

View All Listings by this Company

Print This Approval


#240555058

'LMI.Hygienic HI-Build Epoxy'. Factory applied, two- component, blue coloured epoxy coating. Mix base and hardener in a weight ratio of 100:15 and apply as per manufacturer's instructions 'LMIEP1403032', dated '22/06/2024'. Cure for 2 hours@20°C. For use with water up to 23°C. This material is only approved for the mixing & curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.

Section:
5030 Coatings, Paints & Linings
Section Subtitle:
Factory applied pipe & fittings coatings.
WRAS Approval Number:
240555058
Expiry date:
31/05/2029

Approval Holder:
L.M.I. Ductile Iron Pipes & Fittings
Company Name
L.M.I. Ductile Iron Pipes & Fittings
Address
Alnasb, Bousher, Muscat Governorate

View All Listings by this Company

Print This Approval


#240455014

‘Corroless ACO Brush Grades RAL5005 (GB861) and Light Green (GB206)’ (formerly known as 'Acothane Brush Grades Blue & Green'). Site applied, blue or green coloured, two-part polyurethane coatings consisting of an amber coloured, liquid activator and blue or green coloured coating. Mix brush grade and activator in a 3.24:1 weight ratio. Apply as per technical data sheet dated Feb 2020. Cure for 14 days@7°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.

Section:
5042 Coatings, Paints & Linings
Section Subtitle:
Site applied pipe and fittings coatings. Compliance with BS6920 relates to the conditions of cure specified in the listing. If the cure conditions are varied from those described below then compliance with BS6920 cannot be assummed without further testing. Where catalysts are required, only tested catalysts in the recommended concentrations should be used. Manufacturer's advice must be sought if any non standard mixing or curing conditions are being considered.
WRAS Approval Number:
240455014
Expiry date:
30/04/2029

Approval Holder:
Axalta Coatings Systems Huthwaite UK Ltd.
Company Name
Axalta Coatings Systems Huthwaite UK Ltd.
Postcode
NG17 2RG

View All Listings by this Company

Print This Approval


#240255054

'Interline 975 White'. Site applied, two-part epoxy coating which can be applied as one coat or three coats. Mix parts A & B in a 2.2:1 and apply as per manufacturer's TDS 'Ref:4236', 'Issue Date: 04/02/2015'. When applied as a single coat, the coating must be cured for 14 days at 10°C. When applied as a three-coat system, the coating must be cured as follows: coat 1 = 24 hours@10 °C, coat 2 = 24 hours@10 °C & coat 3 = 14 days@10 °C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.

Section:
5042 Coatings, Paints & Linings
Section Subtitle:
Site applied pipe and fittings coatings. Compliance with BS6920 relates to the conditions of cure specified in the listing. If the cure conditions are varied from those described below then compliance with BS6920 cannot be assummed without further testing. Where catalysts are required, only tested catalysts in the recommended concentrations should be used. Manufacturer's advice must be sought if any non standard mixing or curing conditions are being considered.
WRAS Approval Number:
240255054
Expiry date:
28/02/2029

Approval Holder:
AkzoNobel - International Paint
Company Name
AkzoNobel - International Paint
Postcode
NE10 0LX

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 91 of 116

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.