#240902069

Range of in-line water meters with plastic bodies. The inlet incorporates a plastic filter. Maximum working pressure; 16 Bar Maximum operating temperature 50°C

Section:
1505 Water Meters
WRAS Approval Number:
240902069
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Note:
All models available in body lengths of 165, 170 and 190mm
Size:
1" BSP (M)
Marking:
Arad logo, Model and technical information on faceplate. Flow arrow on body.
Installation Requirements:
R001
Expiry date:
30/09/2029
Model:
PD GLADIATOR Q3=4 1124XXXX With 3P register 1132XXXX- With 3G register
Product Images

Approval Holder:
Arad GROUP Ltd.
Company Name
Arad GROUP Ltd.
Address
Kibbutz Dalia 1923900 Kibutzz Dalia
Country
Israel
Phone
+972-4-9897906
General Email
Dars@arad.co.il

View All Listings by this Company
Manufacturer:
Arad GROUP Ltd.
Company Name
Arad GROUP Ltd.
Address
Kibbutz Dalia 1923900 Kibutzz Dalia
Country
Israel
Phone
+972-4-9897906
General Email
Dars@arad.co.il

View All Listings by this Company

Print This Approval


#240904008

Range of ultrasonic remote transmission water meters with stainless steel body. The products incorporate a single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.

Section:
1505 Water Meters
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (M) & 1” BSP (M) Size added October & November 2024 ¾” BSP (M)
Marking:
Manufacturer’s logo, model, WRAS, flow arrow. Date of manufacture (MM/YY) and technical info on body.
Installation Requirements:
R001
Expiry date:
30/09/2029
Model:
LXCY-15 & LXCY-25 Model added October 2024 LXCY-20 3/4" BSP (M) Model added November 2024: LXCY_20 : 3/4" BSP (M)
Product Images

Approval Holder:
Sanchuan Wisdom Technology Co., Ltd.
Company Name
Sanchuan Wisdom Technology Co., Ltd.
Address
Sanchuan Hydraulic Industrial Park, Longgang Section, Hi-Tech Development Zone, Yingtan, Jiangxi, P.R.China

View All Listings by this Company
Manufacturer:
Sanchuan Wisdom Technology Co., Ltd.
Company Name
Sanchuan Wisdom Technology Co., Ltd.
Address
Sanchuan Hydraulic Industrial Park, Longgang Section, Hi-Tech Development Zone, Yingtan, Jiangxi, P.R.China

View All Listings by this Company

Print This Approval


#240704057

Water hammer arrestor with brass body and EPDM ‘O’ ring. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.

Section:
1530 Miscellaneous Fittings
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (M).
Marking:
CIM & Made in Italy on body.
Installation Requirements:
R001
Expiry date:
31/07/2029
Model:
CIM 1450 – Water Hammer shock absorber

Approval Holder:
Cimberio S.p.A
Company Name
Cimberio S.p.A
Address
Via Torchio, 57 San Maurizio d’Opaglio
Postcode
28017
Country
Italy
Phone
+39.0322.923001
General Email
tguidetti@cimberio.it

View All Listings by this Company

Print This Approval


#240902039

Range of VEGAPULS radar sensors for level measurement with plastic bodies. Cold water use only. Open outlet use only.

Section:
1530 Miscellaneous Fittings
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
See model key
Marking:
VEGA logo date of manufacturer (YYYY), serial number and other technical data on body
Installation Requirements:
R001
Expiry date:
30/09/2029
Model:
PSC21.ab-c-d-N-f-g-h-I VEGAPULS C 21 PSC22.ab-c-d- N -f-g-h-I VEGAPULS C 22 PSC23.ab-c-d- N -f-g-h-I VEGAPULS C 23 PS21.ab-c-d- N -f-g-h-I VEGAPULS 21 PS31.ab-c-d- N -f-g-h-I VEGAPULS 31 KEY FOR VEGAPULS C 21 ab = explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, RCM, EAC) VH ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 (Class II, III Division 1, 2) VB ATEX/UKEX/IEC; Gas, Encapsulation, Zone 1, 2 + Dust, Protection by enclosure, Zone 20, 21/22, 21, 22 SH EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 + Dust, intrinsic safety Zone 20, 20/21, 21, 22 SB EAC/SEPRO; Gas, encapsulation, Zone 1, 2 + Dust, encapsulation Zone 21, 22 TH CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, Intrinsic safety, Zone 20, 20/21, 21, 22 (not CCOE) TB CCOE, NEPSI, KTL, TIIS; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 (not CCOE) WH INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 WB INMETRO/IA; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 FB c-FM-us/c-CSA-us; Gas, encapsulation, Zone 1, 2 (Class I Division 2) + Dust, protection by enclosure, Zone 20, 20/21, 21, 22 (Class II, III Division 1) FR c-FM-us/c-CSA-us; Gas, non-incendive, Class I Division 2 + Dust-ignitionproof, Class II, III Division 1 c = Approved as overfill protection, which can be displayed as; X without W with (WHG, VLAREM) d = Ship approval, which can be displayed as; X without S with (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff / Pharmaceutical certificate, which can be displayed as; X without N with (NSF/ANSI/CAN 61) P with (NIH) F with (FDA, EG1935/2004) f = Thread process side / Cable side, which can be displayed as; G Thread G1½ / G1 N Thread 1½NPT / 1NPT R Thread R1½ / R1 g = Cable material / Length, which can be displayed as; A PUR / 5m (approx. 16ft) B PUR / 10m (approx. 32ft) H PUR / 15m (appr. 48ft) J PUR / 20m (appr. 64ft) C PUR / 25m (approx. 82ft) D PUR / individually selectable (acc. to CE, RCM, EAC) D PUR / individually selectable (acc. to c-FM-us, c-CSA-us) h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART W Four-wire Modbus S Three-wire SDI12 i = Sensor setting via smartphone and VEGA Tools app, which can be displayed as; X without B with KEY FOR VEGAPULS C 22 ab = Explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, c-FM-us, c-CSA-us, RCM, EAC) VH ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 (Class II, III Division 1, 2) VB ATEX/UKEX/IEC; Gas, Encapsulation, Zone 1, 2 + Dust, Protection by enclosure, Zone 20, 21/22, 21, 22 SH EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 + Dust, intrinsic safety Zone 20, 20/21, 21, 22 SB EAC/SEPRO; Gas, encapsulation, Zone 1, 2 + Dust, encapsulation Zone 21, 22 TH CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, Intrinsic safety, Zone 20, 20/21, 21, 22 (not CCOE) TB CCOE, NEPSI, KTL, TIIS; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 (not CCOE) WH INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 WB INMETRO/IA; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 FB c-FM-us/c-CSA-us; Gas, encapsulation, Zone 1, 2 (Class I Division 2) + Dust, protection by enclosure, Zone 20, 20/21, 21, 22 (Class II, III Division 1) FR c-FM-us/c-CSA-us; Gas, non-incendive, Class I Division 2 + Dust-ignition proof, Class II, III Division 1 c = Approved as overfill protection, which can be displayed as; X without W with (WHG, VLAREM) d = Ship approval, which can be displayed as; X without S with (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff / Pharmaceutical certificate, which can be displayed as: X without N with (NSF/ANSI/CAN 61) P with (NIH) F with (FDA, EG1935/2004) f = Process fitting, which can be displayed as; G Thread G1½ N Thread 1½NPT R Thread R1½ g = Cable material / length, which can be displayed as; A PUR / 5m (approx. 16ft) B PUR / 10m (approx. 32ft) H PUR / 15m (appr. 48ft) J PUR / 20m (appr. 64ft) C PUR / 25m (approx. 82ft) D PUR / individually selectable (acc. to CE, RCM, EAC) D PUR / individually selectable (acc. to c-FM-us, c-CSA-us) h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART W Four-wire Modbus S Three-wire SDI12 i = Sensor setting via smartphone and VEGA Tools app, which can be displayed as; X without B with KEY FOR VEGAPULS C 23 ab = explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, RCM, EAC) VH ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 (Class II, III Division 1, 2) VB ATEX/UKEX/IEC; Gas, Encapsulation, Zone 1, 2 + Dust, Protection by enclosure, Zone 20, 21/22, 21, 22 SH EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 + Dust, intrinsic safety Zone 20, 20/21, 21, 22 SB EAC/SEPRO; Gas, encapsulation, Zone 1, 2 + Dust, encapsulation Zone 21, 22 TH CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, Intrinsic safety, Zone 20, 20/21, 21, 22 (not CCOE) TB CCOE, NEPSI, KTL, TIIS; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 (not CCOE) WH INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 WB INMETRO/IA; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 FB c-FM-us/c-CSA-us; Gas, encapsulation, Zone 1, 2 (Class I Division 2) + Dust, protection by enclosure, Zone 20, 20/21, 21, 22 (Class II, III Division 1) FR c-FM-us/c-CSA-us; Gas, non-incendive, Class I Division 2 + Dust-ignitionproof, Class II, III Division 1 c = Approved as overfill protection, which can be displayed as; X without W with (WHG, VLAREM) d = Ship approval, which can be displayed as; X without S with (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff / Pharmaceutical certificate, which can be displayed as; X without N with (NSF/ANSI/CAN 61) P with (NIH) F with (FDA, EG1935/2004) f = Thread process side / Cable side, which can be displayed as; F Thread G1 M Thread 1NPT Q Thread R1 g = Cable material / length, which can be displayed as; A PUR / 5m (approx. 16ft) B PUR / 10m (approx. 32ft) H PUR / 15m (appr. 48ft) J PUR / 20m (appr. 64ft) C PUR / 25m (approx. 82ft) D PUR / individually selectable (acc. to CE, RCM, EAC) D PUR / individually selectable (acc. to c-FM-us, c-CSA-us) h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART W Four-wire Modbus S Three-wire SDI12 i = Sensor setting via smartphone and VEGA Tools app, which can be displayed as; X without B with KEY FOR VEGAPULS 21 / 31 ab = explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, c-FM-us, c-CSA-us, RCM, EAC) AX without, for Ex-free area (CE, UKCA, RCM) VC ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) SC EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 TC CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 WC INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 c = Approved as overfill protection, which can be displayed as; X Without W With (WHG, VLAREM) d = Ship approval, which can be displayed as; X Without S With (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff/Pharmaceutical certificate, which can be displayed as X Without N With (NSF/ANSI/CAN 61) P With (NIH) F With (FDA, EG1935/2004) f = Process fitting, which can be displayed as; G Thread G1½ N Thread 1½NPT R Thread R1½ g = Cable entry / connection, which can be displayed as; M M20x1.5 / Cable gland PA black (ø5-9mm), standard h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART i = Sensor setting via smartphone and VEGA Tools app X Without B With
Product Images

Approval Holder:
VEGA Grieshaber KG
Company Name
VEGA Grieshaber KG
Address
Am Hohenstein 113 Schiltach
Postcode
77761
Country
Germany
General Email
info.de@vega.com

View All Listings by this Company
Manufacturer:
VEGA Grieshaber KG
Company Name
VEGA Grieshaber KG
Address
Am Hohenstein 113 Schiltach
Postcode
77761
Country
Germany
General Email
info.de@vega.com

View All Listings by this Company

Print This Approval


#240902065

Range of ‘Thermowatt’ immersion heater elements incorporating brass or DZR heads with either a copper, stainless steel, alloy or titanium heating element and a black EPDM ‘O’-ring. Open outlet use only. Maximum operating temperature 99°C

Section:
1530 Miscellaneous Fittings
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
RT – 1.1/4” BSP (M) to 2.1/4” BSP (M) RF – 48 mm OD
Marking:
Thermowatt logo, Model, Voltage, Size and other information on cap.
Installation Requirements:
R001
Expiry date:
30/09/2029
Model:
Model Code: XXYZS Where XX denotes the boss type and can be replaced with any of the following: RT = Thread Type RF = Flange Type Where Y denotes the heating tube material and can be replaced with any of the following: 1 = Copper 2 = AISI 304 / AISI 304L 3 = AISI 321 4 = AISI 316 / AISI 316L 5 = Alloy 800 / Alloy 825 / Alloy 840 6 = Titanium 7 = AISI 309S 8 = AISI 310 Where Z denotes the brazing system and can be replaced with any of the following: A = Tin Alloy B = Silver Alloy C = Itek Brazing Where S denotes the surface enamelling and can be replaced with either of the following: S = Enamelled Blank = Not Enamelled
Product Images

Approval Holder:
Thermowatt S.p.A.
Company Name
Thermowatt S.p.A.
Address
Via San Giovanni Battista 21 Arcevia
Postcode
60011
Country
Italy
Phone
+39 0731988246
General Email
thermowatt@legalmail.it

View All Listings by this Company

Print This Approval


#240902708

`Prox’ and ‘Wave` ranges of sensor operated flow control devices incorporating a normally closed solenoid valve to control the flow and operated via an infra-red sensor. The inlet incorporates a stainless-steel strainer. Maximum working pressure 8 Bar Maximum operating temperature 65°C

Section:
1530 Miscellaneous Fittings
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
10mm Spigot inlet x 1/2" BSP (M) outlet
Marking:
Y Stern logo on sensor unit
Installation Requirements:
R001
Expiry date:
30/09/2029
Model:
Prox Sensor Range: 620200 620000 620700 Wave Sensor Range: 620420 620500 620810
Product Images

Approval Holder:
Y. Stern Engineering (1989) Ltd
Company Name
Y. Stern Engineering (1989) Ltd
Address
15 Gan Rave Blvd. Yavne
Postcode
8122217
Country
Israel
Phone
+972 8 9326007
General Email
leah@sternfaucets.com

View All Listings by this Company

Print This Approval


#240904713

Range of leak detection devices incorporating a DZR brass body and non-return valve (not intended for and not suitable for backflow protection). Models Stopleak 1 & Stopleak 2 incorporate a spherical valve. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.

Section:
1530 Miscellaneous Fittings
WRAS Approval Number:
240904713
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Note:
This product has not been tested or approved for leak detection claims made by the approval holder.
Size:
Please refer to model.
Marking:
RBM, flow arrow, PN & CR on body. RBM and product info on control unit.
Installation Requirements:
R001
Expiry date:
30/09/2029
Model:
Stopleak 1: ¾” BSP (M) Stopleak 2: 1” BSP (M) Stopleak 3: 1” BSP (M) x ¾” BSP (M) reducer
Product Images

Approval Holder:
Intatec Limited
Company Name
Intatec Limited
Address
Airfield Industrial Estate Hixon Staffordshire
Postcode
ST18 0PF
Country
United Kingdom
Phone
01889272180
General Email
ryan.tilsley@intatec.co.uk

View All Listings by this Company

Print This Approval


#240702045

Range of positive displacement diaphragm pumps with plastic bodies, EPDM ‘O’-rings and TPE diaphragm. The product incorporates an integral bypass relief valve. For use with John Guest LLDPE Pipe. Maximum working pressure 12.0 Bar. Maximum operating temperature 40.0°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
240702045
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
5/16" Push fit, 3/8" Push fit.
Marking:
Aquatec name and logo, model number, serial number and date of manufacture (DD/MM/YY) on adhesive label on body.
Installation Requirements:
R001
Expiry date:
31/07/2029
Model:
535X-2XXW-XXXX, 537X-2XXW-XXXX. Model Code Denotes: 1st & 2nd designators = 53 - Series Demand Delivery Pumps. 3rd designator is port size for pumphead housing, where ‘5’ = 3/8” or ‘7’ = 5/16” . 4th designator is cam angle for flow performance variation only. X can be 0 to 9. 5th designator ‘2’ indicates that pump has bypass relief control. 6th designator is for pressure setting of relief valve. X can be A to Z depending on pressure setting. 7th designator ‘X’ is a code for the specific materials in this model, e.g. Nylon pumphead housing. 8th designator ‘W’ = WRAS Compliant 9th - 12th designators XXXX can be any alphanumeric characters to denote electrical motor and motor mounting base plate combination.
Product Images

Approval Holder:
Aquatec International Inc
Company Name
Aquatec International Inc
Address
17422 Pullman Street, Irvine, CA 92614, U.S.A.

View All Listings by this Company
Manufacturer:
Aquatec International Inc
Company Name
Aquatec International Inc
Address
17422 Pullman Street, Irvine, CA 92614, U.S.A.

View All Listings by this Company

Print This Approval


#240904711

Range of single stage booster pumps incorporating a flow switch. Model 46349 CH 12-14 B is supplied with a pressure vessel and incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with a strainer and stainless-steel braided EPDM lined flexible connection hoses. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
240904711
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Please refer to model.
Marking:
Stuart Turner and technical information on adhesive label on body.
Installation Requirements:
R001 R415
Expiry date:
30/09/2029
Model:
46387 CH 9-14 FL CH Single Stage Automatic Flow Switch: 1” BSP (M). 46349 CH 12-14 B CH Single Stage Boostamatic: 1” BSP (F).
Product Images

Approval Holder:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley-on-Thames Oxfordshire
Postcode
RG9 2AD
Country
United Kingdom
Phone
01491 572655
General Email
stuart.savill@stuart-turner.co.uk

View All Listings by this Company
Manufacturer:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley-on-Thames Oxfordshire
Postcode
RG9 2AD
Country
United Kingdom
Phone
01491 572655
General Email
stuart.savill@stuart-turner.co.uk

View All Listings by this Company

Print This Approval


#23113748

Overhead ceiling or wall mounted (depending on shower arm) shower outlet with chrome plated plastic body, EPDM o-rings and a plastic flow restrictor at the ball joint. Maximum working pressure: Open outlet. Maximum operating temperature: 60°C.

Section:
1650 Shower Outlets
Section Subtitle:
Shower head(s) and/or shower handset(s).
WRAS Approval Number:
23113748
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (M) – inlet to shower arm. ½” BSP (M) – inlet to showerhead.
Marking:
Grohe logo on shower outlet.
Installation Requirements:
R001 R010
Expiry date:
30/11/2028
Model:
26.054 Rainshower Allure 230. The showerhead can be installed together with either of the following shower arms: 27.709 Rainshower Grohe shower arm (wall), 27.711 Rainshower Grohe shower arm (ceiling).

Approval Holder:
Grohe AG
Company Name
Grohe AG
Address
Industriepark Edelburg Hemer
Postcode
58675
Country
Germany
Phone
02372 930
General Email
marc.engelhardt@lixil.com

View All Listings by this Company
Manufacturer:
Grohe AG
Company Name
Grohe AG
Address
Industriepark Edelburg Hemer
Postcode
58675
Country
Germany
Phone
02372 930
General Email
marc.engelhardt@lixil.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 737 of 1011

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.