Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection). Also supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Also supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of Compress 5800i AW vertical cased and insulated indirect unvented stainless steel hot water storage cylinders fitted with a Caleffi 309508 CST temperature and pressure relief valve set at 10 bar & 90°C, and supplied with a Caleffi inlet control group consisting of in-line pressure reducing valve (set at 3.5 bar) and pressure relief valve (set at 6 bar) and incorporates an approved check valve cartridge (verified by test suitable for backflow protection against Fluid Category 2). The cyclinders also supplied with an 18L expansion vessel and Intatec filling loop assembley (FL12041510). Maximum working pressure 10 bar. Maximum operating temperature 80°C.
Range of wall mounted thermostatic blending valves (chromium plated brass) incorporating a single sequential headwork with a single lever operating member. The inlets incorporate a concentric isolation valve, plastic flow regulator & stainless-steel strainer. The outlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60ºC.
Range of wall mounted bar type shower mixing valve (brass body, various finishes - see model). The product incorporates a ceramic cartridge headwork with a single lever operating member. The hose outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of concealed, wall mounted thermostatic blending valves with brass bodies (chromium plated trim sets). The products consist of a two-way diverter and a thermostatic cartridge controlling the temperature. All models incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5 bar. Maximum operating temperature 60°C.
Range of thermostatic, concealed, 2 and 3 outlet shower valves with (brass bodies - various finishes) incorporating a thermostatic cartridge controlling the temperature and diverter cartridge which also controls the flow. The 2 outlet models, the cartridge only controls flow. The products contain an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow prevention. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of concealed wall mounted thermostatic shower valves, (brass bodies – various finishes & strim sets). Incorporating either a ceramic disc headwork, two-way diverter or both (see models). The temperature is controlled independently via a thermostatic cartridge. The valves incorporate approved single check valve cartridges, however, the complete products have not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 44.0°C
Range of wall mounted concealed thermostatic blending valves with (brass bodies – various finishes), incorporating single lever or cross top operating members. The inlets incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar. Maximum operating temperature 60.0°C.
Range of concealed thermostatic shower mixers (brass bodies - various finishes). The flow is controlled by a four-way manual diverter (3 on, 1 off positions) with single lever, cube type or dome type operating members. The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button with single lever, cube type, dome type or cross top operating members. The inlets incorporate an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of wall mounted thermostatic blending shower valves (brass bodies – various finishes) incorporating quarter turn ceramic disc two-way diverter headwork controlling the flow with dome or square type operating members. Temperature is controlled independently via a thermostatic cartridge incorporating a manual override button with dome or square type operating members. The inlets incorporate a stainless-steel strainer and approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure; 5 Bar Maximum operating temperature 60°C
Range of wafer and fully lugged butterfly valves with a blue epoxy coated cast iron bodies, EPDM seat and a stainless steel (2302/2502 models) or chrome plated iron disc 2304/2504 models). Products are either handwheel (H) or gear (G) operated (see models). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of plastic, ceramic disc diverter valves. For insertion into specifically dimensioned bores. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of two-way manual diverter valves with shut-off position. Products are for insertion into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of regulating and shut-off valves with brass bodies and EPDM ‘O’-Rings. Maximum working pressure 16.0 Bar for BSP (M) and 25.0 bar for BSP (F). Maximum operating temperature 85.0°C
Range of globe type spring loaded, resilient trim, non-return valves with epoxy coated ductile iron bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of globe type spring loaded, resilient trim, non-return valves with epoxy coated ductile iron bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of swing gate, non-return valves with (blue or red epoxy powder coated) ductile iron bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Page 69 of 113
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.