Range of end feed copper fittings for use with copper tube to EN 1057. The HLDPMFWT and HLDPMFZT models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed brass fittings for use with copper tube (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper fittings for use with copper tube to EN 1057. The 30065321,30065313, 30065317,30465313,30065301, 30065305, 30065309, 30465301 & 30465305 models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper fittings for use with copper tube to EN 1057. The 950513 & 950514 & 950501, 950503 & 953102 models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of copper capillary, bronze or brass end feed fittings for use with copper pipe (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Non-metallic materials and components comply with BS6920 at 99°C
Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.
Range of pressure limiter with stainless steel spring, plastic or chrome plated brass bodies. A5.0022.0 and A5.0027.0 incorporate with a stainless-steel mesh filter. Maximum working pressure 10.0 Bar. Maximum operating temperature 65˚C.
Range of vertical multistage booster pumps, with stainless steel bodies and impellors. Maximum working pressure: See models Maximum working temperature 85°C.
Range of hand shower sets comprising of a wall mounted elbow, shower hose, shower handset and shower holder. The shower handset has a chrome plated plastic body and the inlet incorporates a stainless steel strainer and approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The elbow incorporates a quarter turn ceramic disc headwork with dome type operating member and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of disposable shower kits, consisting of shower handset and shower hose with EPDM ‘O’-rings. Maximum operating temperature 65.0°C.
Wall mounted shower outlet with chrome plated body. The inlet incorporates a flow regulator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow prevention. Maximum operating temperature 60°C
Range of shower outlets and shower arms (brass bodies - various finishes - see model). The wall mounted and ceiling mounted shower heads incorporate integral plastic flow regulators and also include stainless steel strainers on the inlets. The shower handset has a plastic flow regulator and a stainless steel strainer on the inlet. Maximum operating temperature 60°C.
Range of shower handsets with a black plastic body and EPDM ‘O’-rings. Model includes a trigger mechanism that alters the spray pattern. Maximum operating temperature 60°C.
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever, dome type or cross top operating members and plastic backnuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wholesome-water nickel plated brass manifolds for use with ‘Emmeti Gerpex RA’ Pexb/Al/Pexb Multilayer pipe and ‘Emmeti Alpert’ PERT/AL/PERT Multilayer Pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C. Range of closed circuit use nickel plated brass manifolds for use with ‘JG Speedfit Layflat Polybutylene Barrier Pipe (models 10BPB & 15BPB)’. Maximum working pressure 3.0 bar. Maximum operating temperature 92°C.
Range of concealed manually operated blending valves (brass bodies with chromium plated exposed trim sets) incorporating self-cancelling diverters (except models added December 2023 – 36020626 & 36020832) ceramic cartridge headworks controlling both temperature and flow with a single lever operating member. The inlets and the outlet incorporate approved check valve cartridge however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C.
Wall mounted, manual blending shower valve, (chromium plated brass), incorporating quarter turn ceramic disc headworks with cross top operating members and a manual diverter to two shower outlets. The product is supplied with a shower riser, overhead shower rose, shower hose and handset. Each inlet incorporates a combined NBR washer and stainless-steel strainer, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar. Maximum working temperature 60°C.
Range of concealed thermostatic valves with thermostatic cartridges. Some models include diver between outlets. (See model codes) All models incorporate cube, dome, cross-top or single lever type operating members. The inlets incorporate stainless steel strainers and single check valve cartridges; however, the complete products have not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted thermostatic shower valves (chrome plated brass). Flow is controlled by a ceramic disc diverter cartridge, using dome type operating members. Temperature is controlled independently via a thermostatic cartridge using a dome type operating member which also incorporates a manual override button. Both inlets incorporate stainless steel strainers and approved check valve cartridges, however, the complete products have not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Two-hole wall mounted thermostatic mixing valve (chrome plated brass body). Incorporating ceramic disc headwork, with a lever type operating member. The temperature is controlled independently via a thermostatic cartridge with a lever type operating member and manual override button. Both inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10 bar. Maximum operating temperature 60°C
Page 68 of 207
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.