Range of deck mounted, two hole, single outlet (fixed) combination tap assemblies with brass bodies (chrome plated). Incorporating quarter turn ceramic disc headworks, dome type operating members and self cancelling diverter to shower outlet. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member that also incorporates a manual override button. Both inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Models TL30024CP and TR30024CP are supplied with a shower riser rail, shower hose and shower handset. Maximum working pressure 5.0bar. Maximum operating temperature 60°C.
Two hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating non-rising spindle headworks with cross top operating members. The spout outlet incorporates a plastic flow straightner. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet swivel combination tap assembly in various finishes (see model) incorporating quarter turn ceramic disc headworks with a cross top operating members. The spout outlet incorporates a plastic aerator. Supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating members and a lockable manual diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with hose, handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Deck mounted two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a lockable self- cancelling diverter to the shower outlet. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member that incorporates a manual override button. Both inlets incorporate stainless-steel strainers and a single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). The spout outlet incorporates a plastic flow straightener and a stainless steel mesh Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
A range of three hole, single outlet (fixed) combination tap assemblies with brass bodies (chromium plated), incorporating quarter turn ceramic disc headworks and various operating members (see models). The side valves and the spout are connection via stainless steel braided EDPM lined flexible hose assemblies incorporating ½” BSP captive nut end connections. Inlet to the main body incorporates a flow regulator. The products are supplied with metal back nuts and pop-up wastes. Maximum working pressure 5.5 bar. Maximum working temperature 60°C.
Range of three-hole, single outlet (fixed) combination tap assemblies (chrome plated brass). Incorporating a quarter turn ceramic disc headwork, and dome type operating members (model RAKPER3011C) or cubed type operating members (model RAKPES3011C). Supplied with stainless steel braided EPDM lined hoses, intended for connection between the valves and the spout assembly The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted three-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating a quarter turn ceramic disc headwork with various operating members (see model). The spout outlets incorporate a plastic flow straightener (models GEO-109-C/P & GEO-109/220/CP) or a plastic aerator (all other models) Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of three hole, single outlet (fixed) combination tap assemblies, brass bodies (various finishes) incorporating quarter turn ceramic disc headworks with various styles of operating members. The spout outlet incorporates a plastic aerator and is connected to the headworks via stainless steel braided EPDM lined hose assemblies. The product is supplied with either a lever type pop up (HIRONDELLE models) or click type waste (ICON-X & CORVAIR models). Maximum working pressure 3.5 Bar. Maximum operating temperature 60°C.
Range of four-hole, single outlet (fixed) combination tap assemblies, (brass bodies - various finishes), incorporating quarter turn ceramic disc headworks with various operating members and a self-cancelling diverter to shower outlet. The spout outlets incorporate plastic aerators. The products are supplied with a shower hose and metal back nuts. The hose connector incorporates an approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of wall mounted spout outlets with either stainless steel or brass bodies (various finishes - see model), incorporating a plastic aerator and EPDM ‘O’-rings. Maximum working temperature 60°C.
Range of spout outlets (chromium plated) brass bodies. Model 13 800 782 incorporates a plastic aerator. Maximum operating temperature 60°C
Range of wall mounted spout outlets with a chromium plated brass bodies and NBR ‘O’-rings. The outlets incorporate a plastic aerator. Maximum operating temperature 85°C.
Filling loop assemblies consisting of a brass bodied spherical valve, stainless steel braided EPDM lined flexible hose (051603F-BAGR4 model) or copper pipe (0516-ATAGBAG model) and a combined double check valve assembly incorporating a spherical valve with a DZR brass body, verified by test (suitable for backflow protection against Fluid Category 3). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Filling loop assemblies comprising of a stainless steel braided, EPDM lined hose, double check valve assembly with isolation valve verified by test (suitable for backflow protection against fluid category 3) and either a straight or tee isolation valve. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC.
>B< Range of copper push-fit fittings for use with copper tube manufactured to EN 10226-1. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Uponor Uni Pipe PLUS system incorporating Uponor RTM metal and PPSU fittings for use with Uni Pipe PLUS PE-RT/AL/PE-RT pipes. Maximum operating pressure 10.0 bat at 70°C.
Range of brass, chrome plated brass or DZR brass compression fittings for use with copper pipe only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Center Brand range of brass and copper end feed fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Single low-level horizontal mount float switch with stainless-steel body and float. Maximum operating temperature 100°C.
Range of WC pressure flushing valves with a solenoid valve controlling the flow. The valves are operated via an infra-red sensor or push-button assembly. The solenoid valve also incorporates a lever operated isolation valve. Maximum working pressure – 5.0 Bar. Cold water use only
Range of stainless-steel plate heat exchangers with EPDM gaskets. The primary circuit, (excluding the E2 prefix models), incorporates a drain valve and a pump (excluding STP prefix models including an ‘N’ as the 14th figure). Operating parameters: Maximum working pressure of the secondary circuit: 6.0 bar or 10.0 bar (see model). Maximum working pressure of the primary circuit: E4 models: 6.0 bar. C3, E3, E2, i2: 10.0 bar. Models added February 2023 – Econoplate STP3, STC3, STP2, STC2 & STP4: 10.0 bar. Maximum operating temperature: Primary 140°C & Secondary 85°C.
Domestic hot water heat recovery unit incorporating a stainless-steel plate heat exchanger and cylinder. Maximum working pressure 3.0 bar. Maximum operating temperature 60°C.
Electric instantaneous, vented mains water heater with plastic a housing and silicon rubber hose. Maximum operating temperature 98°C.
Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Greenstar Heatslave II range of floor standing oil-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system, which incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The cold water inlet incorporates a screwdriver operated spherical valve followed by a plastic flow regulator inserted within the pipework. Maximum working pressure: Primary circuit 2.5 bar. Secondary circuit 10.0 bar. Maximum operating temperature 82°C.
"Greenstar" range of indirect heat interface units and "Flow 8000" (added December 2024) range of direct heat interface units providing heating and instantaneous hot water. The heating system incorporates an expansion vessel. The products are sold with or without a prefix kit (see model), which comprises of a mounting bracket that includes spherical valves for all circuits. The "Greenstar" indirect models include a pressure relief valve (set at 3.0 bar) on the space (central) heating circuit. Greenstar models: Maximum working pressure district heating 10.0 bar. Maximum working pressure space heating 2.5 bar. Maximum working pressure secondary hot water 10.0 bar. Maximum operating temperature 60°C (secondary) and 90°C (primary). Flow 8000 models (added December 2024): Maximum working pressure district and space heating 10.0 bar. Maximum working pressure secondary hot water 10.0 bar. Maximum operating temperature 60°C (secondary) and 90°C (primary).
Water meter with a DZR brass body, stainless steel temperature sensors and EPDM ‘O’-rings. The inlet incorporates a plastic strainer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘RSM’ range of ultrasonic water meters with blue epoxy coated ductile iron bodies, stainless steel transducer and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of water meter manifolds with gun metal bodies and ball valve with either a quarter turn stop valve or screw down stop valve. The products incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.
Range of three or four-hole single outlet (swivel) combination tap assemblies with brass bodies (various finishes). Four hole models Incorporate quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to a shower outlet.. Three hole models Incorporate a ceramic cartridge headwork with a single lever operating member and a self-cancelling diverter to a shower outlet. The spout outlet incorporates a plastic aerator and is connected to the headworks via stainless steel braided PEX lined hose assemblies. The product is supplied with a shower hose and shower handset. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Range of concealed thermostatic mixing valves with DZR brass bodies incorporating a thermostatic cartridge controlling the temperature. The inlets incorporate asingle check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of spout outlets with brass bodies (various finishes) incorporating an aerator. Product is supplied with either a lever type pop up (HIRONDELLE models) or click type waste (ICON-X & CORVAIR models). Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Spout end flow control device (aerator with ‘switchable’ spray formation). Maximum operating temperature 65°C.
Range of vertical multistage pumps with stainless-steel bodies, stainless-steel impellers, shaft and outer sleeve. Maximum working pressures: T (oval flange): 16.0 bar. V (Victaullic & grooved), C (clamp flanges) & F (round flange) versions: 26.0 bar. Maximum operating temperature 100°C.
Range of multistage pumps with brass suction and discharge bodies, stainless steel housing, shaft and impeller, and EPDM ‘O’-rings and seals. Maximum working pressure: 6.0 bar (41491 & 41492 models) or 9.0 bar (41493 & 41494 models). Maximum operating temperature 65°C.
Range of shower outlets and shower kits. Shower outlets consisting of wall and ceiling mounted shower heads and hand shower. The inlets incorporate stainless steel flow regulators and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The shower kits can consist of shower hose, shower handset, riser rail and wall outlet elbow with bracket (depending on model). Shower handset inlet incorporates a stainless-steel strainer. Both the outlet of the wall elbow and inlet of shower handset incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of filter type fixed ‘shower’ outlets and shower handsets with plastic bodies. Maximum operating temperature 45°C.
Range of filter type fixed ‘shower’ outlets and shower handsets with plastic bodies. Maximum operating temperature 45°C.
Range of shower outlets incorporating brass bodies (various finishes) and NBR ‘O’-rings. Maximum operating temperature 85°C.
Shower outlet incorporating brass body (gold effect finish), incorporating a flow regulator and EPDM O-rings. Maximum operating temperature 60ºC.
Shower head with a brass body (various finishes), incorporating EPDM O- rings and a stainless-steel strainer at the inlet. Maximum operating temperature 60.0°C
Shower handset incorporating a chrome plated plastic body and EPDM ‘O’-rings. Maximum operating temperature 60°C.
Wall mounted outlet bracket incorporating a brass body (various finishes) and EPDM ‘O’-rings. Maximum operating temperature 60°C.
Range of in-line `Y` patterned strainers with bronze bodies and stainless-steel strainer. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C. Closed circuit up to 110°C
Deck mounted laboratory tap, grey powder coated brass body, with three outlets: two are fixed, one is a swivel spout. Each outlet has its own individual quarter turn ceramic disc headwork controlling the flow with a dome type operating member, and a hose union attachment. The product is supplied with a brass backnut. Maximum working pressure 6.0 bar. Maximum operating temperature 85°C.
Range of pillar taps with brass bodies (various finishes) incorporating non-rising spindle headworks using either dome type or cross top operating members. Spout outlets incorporate plastic flow straighteners. The products are also supplied with metal back nuts. Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Range of pillar taps (chrome plated) brass bodies with quarter turn ceramic disc headworks and single lever type operating members. The spout outlet incorporates a plastic flow straightener. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of TPE and TPS lined flexible hose assemblies incorporating NBR ‘O’-rings and various end connections. Maximum operating temperature 60°C.
Range of PET (Polyethylene terephthalate) braided flexible hoses incorporating PEX liner and EPDM ‘O’-rings. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Page 66 of 222
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.