Range of “Effast” ABS fittings for use with ABS pipe complying with BS EN 5391-2006. Maximum working pressure: 15 Bar. Maximum operating temperature: 23°C.
Range of DZR brass push fit fittings for use with copper pipe (manufactured to BS EN 1057), PB pipe (manufactured to BS7291-2) and PEX pipe (manufactured to BS7291-3). Maximum working pressures and operating temperatures: 12.5 @ 20°C, and 3.0 bar @ 92ºC.
Range of press fittings with a stainless steel body and EPDM ‘O’ rings for use with stainless steel 316L pipe manufactured to EN10312. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of Conex >B< press fittings incorporating copper & brass bodies for use with copper tube (manufactured to EN1057). Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of end feed copper solder fittings for use with copper tube. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of copper end feed solder fittings for use with copper tube (EN1057). For above and below ground use. Maximum working pressure for sizes 8mm to 54mm is 25.0 bar. Maximum working pressure for sizes above 54mm is 16.0 bar. Maximum operating temperature 99°C.
Range of stainless-steel plate heat exchanger assemblies incorporating single or twin pumps on the primary circuit. Maximum working pressure 10 Bar (UKE-8 models) or 6 bar (UKE-14 models).
Non-metallic materials and components comply with BS6920 at 85°C
Range of stainless-steel plate heat exchangers. Maximum working pressure 10 bar. Maximum operating temperature 90°C.
Range of wall mounted combination boilers providing domestic hot water via a heat exchanger and pressurised central heating system. The products can be supplied with a rigid or flexible filling loop or keyless filling link. The flexible and rigid filling loops incorporate a flexible hose or copper pipe, isolation valve, double check valve assembly (suitable for back flow protection against fluid category 3). The keyless filling link incorporates a CAB backflow prevention device (suitable for back flow protection against fluid category 3). The products also incorporate an expansion vessel and pressure relief valve set at 3.0 bar. Maximum working pressure of primary circuit 2.5 bar. Maximum operating temperature of primary circuit 85°C Maximum working pressure of secondary circuit 8.0 bar Maximum operating temperature of secondary circuit 60°C
Range of shower outlets (brass or stainless-steel bodies – various finishes) incorporating EPDM O-rings. Maximum operating temperature 60.0°C
Non-metallic materials and components comply with BS6920 at 60°C
Page 64 of 116
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.