'Relithane 151. Factory applied, brown coloured, two-component Polyurethane coating. Mix base and hardener in a 2.5:1 ratio and apply as per manufacturer's 'Standard Operating Procedure & Guidelines, Revision 2, 157/2022' dated 12th October 2022. Cure for 40 seconds@35°C. For use with water up to 65°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Pentaline 1000 HT Red'. Factory applied, red coloured (once mixed), two-component epoxy coating. Mix base and hardener in a volume ratio of 3:1 and apply as per manufacturer's instructions 'Chembur R&D/PI/23/02' dated 28/12/2023. Cure for 7 days@30°C. For use with water up to 65°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘SIGMAPRIME 200 K Grey’ for use with ‘SIGMAGUARD CSF 585 (white)’ or ‘SIGMAGUARD CSF 585 (blue)’. Factory applied, white or blue coloured (once mixed and applied), two-part epoxy coating comprising of Coat 1 and Coat 2. ‘SIGMAPRIME 200 K Grey’ (Coat 1) comprises of a base and hardener to be mixed in a 80:20 volume ratio and applied as PDS ‘7416’, dated February 25, 2021. Cure for 24 hours@23°C. ‘SIGMAGUARD CSF 585 (white)’ or ‘SIGMAGUARD CSF 585 (blue)’ is to be applied as Coat 2 and each comprises of a base and hardener to be mixed in a 77.5:22.5 ratio and applied as PDS ‘7785’, dated August 19, 2022. Cure for 12 days@20°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'LMI Hygienic CML'. Factory applied, grey coloured cement mortar. Mix cement mortar:sand:water in a weight ratio of 36:46:18 and apply as per manufacturer's instructions 'LMICMA012624', dated '1/26/2024'. Cure for 20 hours@40°C. For use with water up to 50°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Alsen FBE Blue Powder Coating'. Factory applied, blue coloured epoxy coating. Apply as per manufacturer's Product Data Sheet 'AIPL 1212/1', dated '07/06/2023'. Cure for 2.5 hours:235°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'JSC-01'. Factory applied, grey coloured cement mortar. Mix sand:water: cement in a 1.5:1.0:1.0 weight ratio and apply as per manufacturer's instructions 'GB0012023', edition 'A1'. dated '2023-10-10'. Cure for 24 hours at 25°C. For use with water up to 65°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Crystic Gelcoat 65PA Gel Coat' for use with 'Crystic 125PA GRP resin'. GRP resin, manufactured by hand lamination, for use with white coloured, factory applied gel coat. Apply as per manufacturer's quick guide 'issue number 1', dated 04/06/2018. Cure for 24 hours@23°C and then 3 hours@80°C. For use with water up to 50°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Magnetic Rotor, 011201_02_02'. Black coloured, injection moulded nylon magnet rotor component. For use with water up to 85°C.
'122102251 PP Mechanical Fitting'. Black coloured, injection moulded, polypropylene compression fitting body. For use with water up to 23°C.
'60EP126p'. Black coloured, compression moulded EPDM 'O' rings. Shore hardness 60. Tested in-radius size 0.6mm. For use with water up to 85°C.
'WN12/7/1 BLK 'O'-rings'. Black coloured, injection moulded NBR 'O' rings. Tested in-radii sizes between 0.89mm and 2.0mm. Shore hardness 70. For use with water up to 65°C.
‘Trutite Pipe Sealing Cord’. White coloured nylon cord coated with a silicone paste, intended for use as a thread sealant. The cord is to be applied and tightened in accordance with Data Sheet ‘version 1.3’, dated 12/02/24 and this material is only approved for these conditions. For use with water up to 85°C.
‘CORE® Pipe Sealing Cord’. White coloured nylon cord coated with a silicone paste, intended for use as a thread sealant. The cord is to be applied and tightened in accordance with Data Sheet ‘version 1.2’, dated 12/01/23 and this material is only approved for these conditions. For use with water up to 85°C.
'PVCC125 & PVCC250 PVC Pipe Cement'. Clear, transparent (un-pigmented) solvent cement, (intended to join PVC pipe and fittings). Apply as per manufacturer's instructions 'Rev00 24012024'. Cure for 20 days at 7°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Range of screw down stop valves with plastic bodies incorporating EPDM ‘O’-rings and seal. For use with PE-X pipe (manufactured to BS7291-3), BPB pipe (manufactured to BS7291-2) and copper pipe (manufactured to EN1057). Maximum working pressure and operating temperatures: 12.5 bar @ 20°C & 6.0 bar @ 65°C.
'122102001 Valve Body'. Black coloured, injection moulded PVC-U valve body. For use with water up to 23°C.
Range of wall mounted single hole, single outlet (fixed) electronically controlled tap assemblies, (chrome plated - brass bodies). Flow is controlled by a solenoid valve activated by via an infra-red sensor. The spout outlets incorporate a plastic aerator. Maximum working pressure 10 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) electronically controlled tap assemblies (either black finish or chromium plated brass bodies). Flow is controlled by a solenoid valve which is actuated via an infra-red sensor. The spout incorporates a stainless-steel strainer on the outlet. The product is supplied with a stainless steel braided PEX lined flexible hose assembly and a combination valve with a DZR brass body consisting of a servicing valve, a single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2), a stainless-steel strainer and plastic flow regulator on the outlet. The combination valve has a compression inlet for use with copper pipe (manufactured to BS EN 1057). The tap incorporates a soap dispenser with a separate dispensing nozzle. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
WC flushing cistern incorporating a side entry BS 1212-4 (2016) compact type float operated inlet valve providing a Type AG air gap with a dual flush valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 3.5 litres. The cistern is operated by an electronically controlled flush valve. The product also incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Page 57 of 124
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.