Range of combined stop valve and drain off valves with brass bodies and EPDM O-rings. Maximum working pressure 16 Bar Maximum operating temperature 65°C
Range of screw down stop valves with brass bodies, NBR seals and ‘T’ type operating members. Compression connection to be used with copper pipe EN1057 only. Maximum working pressure 16 bar. Maximum operating temperature 85°C.
Range of manually operated balancing valves with bronze bodies, DZR brass disc and EPDM rubber 'O’-rings. Both models have test points. The F9506 models also have a drain point on the high-pressure test side. Maximum working pressure 25.0 bar. Maximum operating temperature 100°C.
Range of commercial washing machines with flow controlled by solenoid valves and discharged via type AB air gap assembly (verified by test - suitable for backflow protection against fluid category 5). The inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5 Bar. Maximum operating temperature 60°C.
Range of inline water conditioners with stainless steel bodies and catalytic alloy core. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
‘G5 CS’ command centre providing chilled or chilled sparkling water (both filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The product incorporates a pressure reducing valve (adjustable outlet pressure between 2.25 and 2.75 bar) on the supply to the carbonator unit. The carbonator inlet incorporates a non-return valve. The product is supplied with a filter cartridge. The inlet to the command centre incorporates two approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum inlet supply pressure 5.0 bar. Cold water use only.
'ELECTROCOAT BP 1119'. Factory applied, black coloured Bituminous Paint. Apply as per manufacturer's TDS Document No: 'ECL/ TDS / BP-1119-Bituminous Paint', Issue Date '10-Aug-20', Version No: '01'. Cure for 12 minutes at 45°C, followed by 10 hours at 28°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Hempathane PW 35660 blue & off-white`. Factory applied, two-component polyurethane liquid coating consisting of a base and curing agent. Mix base and curing agent in a 3:1 volume ratio and apply as per product data sheet dated December 2023. Cure for 7 days@20°C. For use with water up to 35°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘Sikagard®-180’. Site applied, grey coloured, two-component epoxy coating consisting of Part A (grey coloured liquid) and Part B (colourless liquid). Mix Part A and Part B in a mass ratio of 87:13 and apply as per manufacturer's TDS 'MBS_CC-UAE/Pr_180_05_18/v9/02_22/v10/05_23/v11/01_24'. Cure coat 1 for 36 hours@20°C. Cure coat 2 for 21 days@20°C. For use with water up to 40°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘Sikagard®-1814 - RAL 7035’. Site applied, grey coloured (once mixed), two-component epoxy polysulfide resin coating. Mix Part A (light grey, opaque liquid) and Part B (light yellow, translucent liquid) in a 78:22 weight ratio and apply 2 coats as per manufacturer’s TDS ‘MBS_CC-UAE/Pr_1814_06_23/v1/01_24’. Cure coat 1 for 9 hours@25°C. Cure coat 2 for 14 days@25°C. For use with water up to 50°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Page 519 of 854
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.