‘Showermate Universal’ range of booster pumps with plastic bodies and impellers, stainless steel shafts, brass manifolds, NBR ‘O’-rings and EPDM seals. The product incorporates a pressure vessel. The outlet(s) incorporate(s) an approved single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection The inlet hose(s) supplied with this product incorporate(s) an isolation valve. Maximum working pressure 4.0 bar. Maximum operating temperature 65°C.
Range of cold water in tank booster sets incorporating an ‘AG’ air gap, consisting of a GRP water storage cistern incorporating a float operated inlet valve, with a copper float and submersible pump or pumps (depending on model). The products incorporate an externally mounted stainless-steel manifold with servicing valve(s), expansion vessel, pressure gauge and a digital control panel. The pumps are connected to the external components via a discharge assembly of internal pipework including an in-line non-verifiable single check valve assembly (suitable for backflow prevention of Fluid Category 2). Maximum working pressure 10.0 bar. Cold water use only.
Range of cold water in tank booster sets incorporating an ‘AB’ air gap, consisting of a GRP water storage cistern incorporating a float operated inlet valve, with a copper float and submersible pump or pumps (depending on model). The products incorporate an externally mounted stainless-steel manifold with servicing valve(s), expansion vessel, pressure gauge and a digital control panel. The pumps are connected to the external components via a discharge assembly of internal pipework including an in-line non-verifiable single check valve assembly (suitable for backflow prevention of Fluid Category 2). Maximum working pressure 10.0 bar. Cold water use only.
Range of pumps with stainless steel bodies and plastic impellors. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
Shower handset with plastic bodies (chrome plated). Maximum operating temperature 65°C.
Range of shower handsets (chromium plated) brass bodies and NBR O-rings. The inlets incorporate stainless-steel strainers and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Open outlet use only. Maximum operating temperature 60ºC
Shower head with white ABS body. Maximum operating temperature; 75°C. Maximum operating pressure; Open outlet use
A range of shower kits and hand showers incorporating metal bodies (chrome plated). Some models are supplied with sliding rails, wall elbows and shower hoses (see models). Maximum working temperature 60°C.
Range of overhead shower outlets with brass bodies in various finishes (See models) incorporating EPDM ‘O’-rings and seals. The inlet to the shower heads incorporate either a plastic steel sieve (26 031 xxx) or a stainless steel (26 032 xxx) has a stainless-steel sieve. The inlet for the shower head incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection (Model 26 031 xxx only). Maximum operating temperature 60°C.
Shower head incorporating a chrome plated plastic body and NBR gasket, Maximum operating temperature 85°C.
Range of plastic shower handsets (various finishes). Maximum operating temperature 75°C.
Range of overhead shower outlets with stainless steel bodies (various finishes). The inlet incorporates a stainless steel filter and a plastic flow regulator. Maximum working temperature 60°C.
Range of wall mounted shower outlets with a brass bodies (chrome plated). The outlet incorporates a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum operating temperature 60°C.
Range of overhead shower outlets incorporating metal bodies (various finishes) and flow regulator and strainer on the inlets. Maximum operating temperature 43°C.
Range of overhead shower outlets incorporating metal bodies (various finishes) and flow regulator and strainer on the inlets. Maximum operating temperature 43°C.
Range of shower kits, comprosing of shower handset, shower hose, riser rail and overhead shower outlet depending on kit. Inlets incorporate a flow regulator (models 1.1740.578 & 1740.155) Maximum operating temperature 60°C.
Range of overhead showers with brass and plastic bodies (various finishes - see models). The inlet incorporates a stainless-steel strainer and a plastic strainer. Products to be used with basic sets with brass bodies and EPDM O-rings. Open outlet use only
Non-metallic materials and components comply with BS6920 at 60°C
Range of filter type fixed ‘shower’ outlets and shower handsets with plastic bodies. Maximum operating temperature 45°C.
Range of flow switches incorporating brass or stainless steel bodies. Maximum working pressure 25.0 bar. Maximum operating temperature 100°C.
Range of flow sensors with brass or plastic bodies. Flow sensor type series VTY10 (plastic body, G3/4): Maximum working pressure 10.0 bar. Maximum operating temperature 85°C. Flow sensor type series VTY10 (plastic body, Quickfasten OD 22.5mm): Maximum working pressure 10.0 bar. Maximum operating temperature 70°C. Flow sensor type series VTY10 (brass body, G1/2): Maximum working pressure 16.0 bar. Maximum operating temperature 90°C.
Page 51 of 521
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.