Directory Search Results

Print List

#250302006

Range of wall mounted, concealed thermostatic basin mixing valves with brass bodies. Temperature is controlled via a thermostatic cartridge and flow is controlled by solenoid valves actuated by an infrared sensor. The outlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar. Maximum operating temperature 60.0°C.

Section:
0681 Combination Tap Assemblies
Section Subtitle:
Miscellaneous.
WRAS Approval Number:
250302006
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
1/2" BSP (M) inlet X outlet 1/2" BSP (F) inlet X outlet
Marking:
Dornbracht logo on valve housing cover
Installation Requirements:
R001 R010 R040
Expiry date:
31/03/2030
Model:
3574097090 -Touchfree Basin mixer with temperature setting for combining with free-standing fittings 3574197090 – Touchfree Basin mixer with temperature setting for combining with wall-mounted fittings 4276597090 - eSET Touchfree Basin mixer with temperature setting - required for installation with 3574097090 and 3574197090
Product Images

Approval Holder:
Dornbracht GmbH & Co. KG.
Company Name
Dornbracht GmbH & Co. KG.
Address
Koebbingser Muehle 6 Iserlohn
Postcode
D-58640
Country
Germany
Phone
+49 2371 433 0
General Email
wpape@dornbracht.com

View All Listings by this Company

Print This Approval


#250104713

The products incorporate two check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3), a pressure reducing valve adjustable between 1.0 bar and 3.0 bar (but pre-set at 2.5 bar for 523.815 model and 1.4 bar for the 523.816 model). The product incorporates a push type valve which allows water to flow when operated until the required pressure is achieved. There is a drain port below the push valve piston chamber. Compression connections are for use with copper pipe (manufactured to EN 1057). Maximum supply pressure 10.0 bar. Maximum operating temperature 80°C.

Section:
1015 Filling Loop
WRAS Approval Number:
250104713
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Note:
The discharge from the drain port must be via a type `AA`, `AB` or `AD` airgap, or in accordance with EN1717.
Size:
15mm compression.
Marking:
Officine Rigamonti spa logo, (the letters ‘OR’ within an oval), flow arrow, CR mark, size and pressure cast on body. Date of manufacture (MMYY) laser etched on body.
Installation Requirements:
R001 R511
Expiry date:
31/01/2030
Model:
523.815, 523.816.
Product Images

Approval Holder:
Officine Rigamonti spa
Company Name
Officine Rigamonti spa
Address
Località Molino Rastelli, 20 13018 Valduggia (VC)
Country
Italy

View All Listings by this Company
Manufacturer:
Officine Rigamonti Spa
Company Name
Officine Rigamonti Spa
Address
Via Circonvallazione 9, Officine Rigamonti spa 13018 Valduggia (VC)
Country
Italy
Phone
+39 0163 48 165 Fax: +39 0163347254

View All Listings by this Company

Print This Approval


#250302704

Range of in-line water filter cartridges with plastic bodies. Maximum working pressure 8.0 bar. Cold water use only.

Section:
1055 Filter Cartridges
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
72.65 OD
Marking:
Grohe logo, model and technical information on adhesive label on body.
Installation Requirements:
R001 R008 R150 R170
Expiry date:
31/03/2030
Model:
Grohe Blue Filter S – Cartridge Single. Grohe Blue Filter M – Cartridge Single. Grohe Blue Filter L – Cartridge Single.
Product Images

Approval Holder:
Grohe AG
Company Name
Grohe AG
Address
Industriepark Edelburg Hemer
Postcode
58675
Country
Germany
Phone
02372 930
General Email
marc.engelhardt@lixil.com

View All Listings by this Company

Print This Approval


#250102713

Range of carbon filter cartridges. Cold water use only.

Section:
1055 Filter Cartridges
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
70mm ØD
Marking:
Ambio logo and model on adhesive label on body
Installation Requirements:
R001 R008 R120 R150 R170
Expiry date:
31/01/2030
Model:
100620 Ambio 40” & 100621 Ambio 20”

Approval Holder:
Ambio AS
Company Name
Ambio AS
Address
Fabrikkveien 10, 4033 Stavanger
Country
Norway
Phone
+47 51 44 64 00
General Email
water@ambio.no

View All Listings by this Company

Print This Approval


#250204002

Range of water meter manifolds with plastic bodies for use with PE80 pipe (manufactured to BS EN 12201) and copper pipe. The products incorporate a drain off valve, plastic strainer and a single check valve cartridge however, the complete products have not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.

Section:
1510 Water Meter Manifolds
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
15mm & 22mm Compression. 25mm Pushfit.
Marking:
Talbot on body
Installation Requirements:
R001 R008 R511
Expiry date:
28/02/2030
Model:
MA3261515AM Internal Meter Manifold Drain off failed 1113.1 MA3261522AM Internal Meter Manifold Drain off MA3262215AM Internal Meter Manifold Drain off MA3262222AM Internal Meter Manifold Drain off failed 1113.1 MA3262515AM Internal Meter Manifold Drain off MA3262522AM Internal Meter Manifold Drain off MA3261515BM Internal Meter Manifold Blank plug MA3261522BM Internal Meter Manifold Blank plug MA3262215BM Internal Meter Manifold Blank plug MA3262222BM Internal Meter Manifold Blank plug MA3262515BM Internal Meter Manifold Blank plug MA3262522BM Internal Meter Manifold Blank plug

Approval Holder:
Atlantic Plastics Ltd.
Company Name
Atlantic Plastics Ltd.
Address
Coytraherne Close, Brackla, Bridgend
Postcode
CF31 2AX
Country
United Kingdom
Phone
01656672628
General Email
rhodgkiss@atplas.co.uk

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 489 of 559

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.