Range of three hole, single outlet (fixed) combination tap assembles (brass bodies - various finishes). Incorporating ceramic cartridge headworks with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies, (brass bodies - various finishes) incorporating quarter turn ceramic disc headworks with various operating members. The spout outlet incorporates a plastic aerator and is connected to the headworks via stainless steel braided TPSiV lined hose assemblies Maximum working pressure 3.5 bar. Maximum operating temperature 60°C
Three-hole, single outlet (swivel) combination tap assembly (brass bodies - various finishes). Incorporating quarter turn ceramic disc headworks with single lever operating members. The products are also supplied with stainless steel braided EPDM lined flexible hose assemblies, intended for use between the side body valves and spout. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar Maximum operating temperature 65.0°C
Five-hole, single outlet (fixed) combination tap assembly (brass body with various finishes – see models), incorporating quarter turn ceramic disc headworks with dome type operating members and a self-cancelling diverter to shower outlet. The product is supplied with stainless steel braided, PEX lined interconnecting flexible hose assemblies. The shower handset incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure: 10.0 Bar. Maximum operating temperature: 60.0°C.
Range of four-hole, single outlet, fixed, combination tap assemblies (brass bodies - various finishes) incorporating quarter turn ceramic disc headworks with various operating members (see models). The products incorporate a self-cancelling diverter to shower outlet. The spout outlets incorporate a plastic flow straighter. The product is not supplied with a shower hose and handset. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of shower outlets (brass bodies - various finishes) comprising of a wall union, shower fixing bracket and a wall elbow. Models WEPB Incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working temperature 65°C. Open outlet use only
Range of wall mounted spout outlets (brass bodies - various finishes). Maximum operating temperature 60°C Open outlet use only.
Range of CU type press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of press fittings (brass bodies - various finishes) with stainless steel press (‘TH’ profile) collars and EPDM O-rings for use with “EA” range of PEX/AL/PEX multilayer pipe (for press fitting connections and compression for EHA adaptor fittings only) or copper pipe manufactured to EN1057 (compression connections). Maximum operating temperature: 95°C. Maximum operating pressure: 10 bar.
‘FRABOPRESS BIG-SIZE’ range of copper and bronze press fittings for use with copper pipe (manufactured to EN1057). Maximum working pressure 10.0 bar. Maximum operating temperature 100°C
‘FRABOPRESS COPPER M’ range of copper and bronze press fittings for use with copper pipe (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
‘FRABOPRESS 316 M’ range of stainless-steel press fittings for use with stainless steel pipe (manufactured to EN 10312:2002 & EN 10217:2021). Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of copper crimped fittings with EPDM ‘O’-rings for use with copper pipe manufactured to EN1057. For above and below ground use. Maximum working pressure 16 Bar. Maximum operating temperature 99°C.
DMFit range of black and grey plastic pushfit fittings for use with DM LLDPE pipes. Supplied with black pipe inserts and metric PEX barrier pipe manufactured to BS7291-2. Supplied with grey pipe inserts. LLDPE pipes are available in black, natural (appearance is white), white, red, and blue colours. Metric sizes - 4, 5, 6, 8, 10, 12mm for use with LLDPE (white, black, red, blue & natural) tubing only. Metric size - 15mm for use with LLDPE tubing (white, black, red, blue & natural) Imperial sizes - 5/32”, 3/16”, ¼”, 5/16”, ⅜”, ½” & ¾” for use with LLDPE tubing (white, black, red, blue & natural). Maximum working pressure: 12.0 bar. Cold water use only. Maximum working pressure: 7.0 bar. Maximum operating temperature: 65°C.
“<A> Press Copper M Profile” series press fittings with a copper body and EPDM ‘O’-rings, for use with copper pipe manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Press-Inox range of stainless-steel crimped fittings (‘M’ crimp profile) for use with stainless steel pipe (manufactured to EN10204). For above ground use only. Maximum working pressure: 16Bar. Maximum operating temperature: 100°C.
Range of copper brazed, stainless steel heat exchangers. Available with between 4 – 70 plates (see models). Maximum working pressure: 16.0 bar. Maximum operating temperature: 99°C.
Range of indirect heat interface units (HIU) providing heating and instantaneous hot water. The central heating and hot water is generated via plate heat exchangers. Maximum operating pressure 10 bar (primary and DHW secondary). Maximum operating pressure 2.5 bar CH secondary Maximum operating temperature 90°C
Range of water meters with brass bodies and EPDM ‘O’-rings and plastic strainer on inlet. Maximum working pressure 16 bar. Cold water use only.
Range of water meter manifolds with plastic bodies for use with PE80 pipe (manufactured to BS EN 12201). The inlets incorporate a spherical valve and a check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.
Page 485 of 566
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.