‘Intergard 269 & Interline 975’. Site applied, white coloured Epoxy coating system comprising of a base coat and a topcoat. ‘Intergard 269’ is a two-component base coat which comprises of Part A (red/brown coloured) and Part B (straw coloured). Mix Part A & Part B in a mass ratio of 7.46:1 and apply as per manufacturer’s TDS ref. ‘206’, dated 08/02/2021. Cure for 12 days@25°C. ‘Interline 975’ is a two-component topcoat which comprises of Part A (white coloured) and Part B (straw coloured). Mix Part A & Part B in a mass ratio of 3.12:1 and apply as per manufacturer’s TDS ref. ‘3577’, dated 31/07/2017. Cure for 14 days@25°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'TEC S147 R.-45 ROSSO'. Orange coloured, injection moulded, silicone rubber 'O' rings & gaskets. Shore hardness 45. Tested in-radius size between 0.5mm & 2.6mm. For use with water up to 85°C.
'Loctite EA 9480'. Site applied, two-component, white coloured (once mixed) epoxy adhesive. Mix and apply as per manufacturer's technical data sheet dated October 2014. Cure for 7 days@22°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Range of wall mounted, single hole, single outlet (fixed) electronically controlled tap assemblies comprising of a concealed brass body and a separate spout and trim set (chromium plated brass). Flow is controlled by a solenoid valve activated via an infra-red sensor. The inlets (within the) concealed body incorporate a plastic filter and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Deck mounted, single hole, single outlet (fixed) electronically controlled tap assembly (various finishes). The flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. Product supplied with metal backnuts. Maximum working pressure 6.0 bar. Maximum operating temperature 40°C.
Deck mounted, single hole, single outlet (fixed) electronically controlled tap assembly (various finishes). The flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. Product supplied with metal backnuts. Maximum working pressure 6.0 bar. Maximum operating temperature 40°C.
Concealed WC dual flushing cistern with a BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush pneumatic outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 14055 (2018) WC Cistern incorporating a side or bottom entry float operated inlet valve discharging via a Type AG air gap and a lever operated dual flush syphon with full flush volumes of up to 6 litres and a reduced flush of up to 3 litres. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry BS1212-4 (2016) compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 3 litres and incorporates a servicing valve and flexible hose on the inlet supply.The cistern is operated by a pnuematic push button Maximum working pressure 10.0 bar. Cold water use only.
Range of one-piece and two-piece pre-insulated GRP cold water storage cisterns. Cisterns are supplied with a float operated inlet valve, screened overflow and screened vent. Cold water use only.
Page 34 of 118
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.