Directory Search Results

Print List

#2306060

Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The products are supplied with a temporary filling loop which incorporates a combined isolation valve and double check valve assembly (suitable for backflow protection against Fluid Category 3), stainless steel braided EPDM lined flexible hose assembly and an isolation valve. The secondary circuit (DHW) incorporates a stainless-steel strainer. The primary circuit incorporates isolation valves on the flow and return. Maximum working pressures: DHW: 10.0 Bar CH:2.5 Bar Maximum operating Temperatures: DHW: 65.0°C CH: 85.0°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2306060
Size:
DHW: 15mm compression CH: 22mm compression
Marking:
Vailant on front cover. Vailant, Model,Pressure, Temperature and other information on adhesive label on rear of body
Installation Requirements:
R001 R140 R360
Expiry date:
30/06/2028
Model:
VUW 20/26CS/1-5 (N-GB) ecoTEC plus 826 VUW 25/32CS/1-5 (N-GB) ecoTEC plus 832 VUW 30/36CS/1-5 (N-GB) ecoTEC plus 836 VUW 30/40CS/1-5 (N-GB) ecoTEC plus 840 VUI 30/40CS/1-5 (N-GB) ecoTEC plus 940

Approval Holder:
Vaillant GmbH
Company Name
Vaillant GmbH
Address
Berghauser Strasse, 40 D-42859 Remscheid
Country
Germany
Phone
Tel: +49 2191 182126

View All Listings by this Company
Manufacturer:
Vaillant Industrial UK Ltd
Company Name
Vaillant Industrial UK Ltd
Address
Nottingham Road Belper Derbyshire
Postcode
DE56 1JT
Phone
01773 824141

View All Listings by this Company

Print This Approval


#2306049

‘Sonata’ range of water meters with plastic or brass/plastic bodies. Maximum working pressure 16.0 bar.

Non-metallic materials and components comply with BS6920 at 50°C

Section:
1505 Water Meters
Size:
DN15 – DN32: ¾” BSP (M), 1” BSP (M) & 1 ¼” BSP (M).
Marking:
Sonata, Arad and product information on body.
Installation Requirements:
R001
Expiry date:
30/06/2028
Model:
‘Sonata’ range

Approval Holder:
Arad GROUP Ltd.
Company Name
Arad GROUP Ltd.
Address
Kibbutz Dalia 1923900 Kibutzz Dalia
Country
Israel
Phone
+972-4-9897906
General Email
Dars@arad.co.il

View All Listings by this Company
Manufacturer:
Arad GROUP Ltd.
Company Name
Arad GROUP Ltd.
Address
Kibbutz Dalia 1923900 Kibutzz Dalia
Country
Israel
Phone
+972-4-9897906
General Email
Dars@arad.co.il

View All Listings by this Company

Print This Approval


#2306053

Range of inline water meters with blue epoxy coated cast iron body. Maximum working pressure 16.0 bar. Cold water use.

Section:
1505 Water Meters
Size:
DN50 - DN100 Flanged
Marking:
Sensus on cover. Sensus logo, size, serial number, and other technical information on meter face. Flow arrow and size on body.
Installation Requirements:
R001
Expiry date:
30/06/2028
Model:
MeiTwin DN50, DN65, DN80 & DN100

Approval Holder:
Sensus UK Systems Ltd
Company Name
Sensus UK Systems Ltd
Address
North Wing Central 40, Crockford Lane, Basingstoke, RG24 8GU
Country
Basingstoke

View All Listings by this Company
Manufacturer:
Sensus GmbH Hannover
Company Name
Sensus GmbH Hannover
Address
Meineckestrasse 10 Laatzen 30880 Germany

View All Listings by this Company

Print This Approval


#2302705

Range of water meters with blue epoxy coated ductile iron bodies, plastic measurement chambers and vanes and NBR ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.

Section:
1505 Water Meters
Size:
Flanged inlet/outlet: DN40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400.
Marking:
GAER on cover Flow arrow & size on side of body, GAER, size, Model number and pressure rating and product info on dial face.
Installation Requirements:
R001
Expiry date:
29/02/2028
Model:
GMW GAER

Approval Holder:
Hidroglobal Tecnologia del Agua S.A.
Company Name
Hidroglobal Tecnologia del Agua S.A.
Address
C/ GARBÍ 3 Pol.Ind. Can Volart PARETS DEL VALLÈS
Postcode
08150
Country
Spain
Phone
+34 93 573 74 00
General Email
calidad@hidroglobal.com

View All Listings by this Company

Print This Approval


#2307805

Permanent filling devices for primary heating and chilled water closed circuits in domestic and non-domestic premises. The mains and closed circuit system pressures are continuously checked by two pressure sensors and their differential monitored by microprocessors. If the mains pressure is adequate and there is a drop in system pressure, then the two solenoid valves operate to allow water into the system via the transfer chamber. At all other times the normally open solenoid valve drains the transfer chamber to waste, via tundish (meeting the requirements of an air gap to drain), and allowing air to be admitted via an automatic air vent to create an atmospheric disconnection across the transfer chamber. Stainless steel strainer on the inlet supply. Mikrofill 3: Maximum working pressure 5.0 Bar. Cold water use only. Mikrofill 3 Pro (72846): Maximum working pressure 9.0 Bar. Cold water use only.

Section:
1530 Miscellaneous Fittings
WRAS Approval Number:
2307805
Note:
Suitable for backflow protection up to fluid category 4. Water companies must be notified prior to installation.
Size:
15mm compression.
Marking:
Mikrofil 3 or Mikrofill 3 Pro, address, model, serial no, date of manufacture, max pressure on technical label.
Installation Requirements:
R001 R120 R415
Expiry date:
28/07/2028
Model:
Mikrofill 3. Model added June 2025: Mikrofill 3 Pro (72846).

Approval Holder:
Mikrofill Systems Ltd.
Company Name
Mikrofill Systems Ltd.
Address
11 Merse Road, Redditch
Postcode
B98 9HL
Country
Worcs.
Phone
+44 (0) 8452 606 020
General Email
info@mikrofill.com

View All Listings by this Company

Print This Approval


#2306048

Flow meter with stainless steel body. Maximum working pressure 16.0 bar.

Non-metallic materials and components comply with BS6920 at 60°C

Section:
1530 Miscellaneous Fittings
Size:
DN100 Flanged
Marking:
Pydro on body. Pydro, Model, Serial no, size and other technical information on data plate on body
Installation Requirements:
R001
Expiry date:
30/06/2028
Model:
PT-1 Multi Sensing Device

Approval Holder:
PYDRO GMBH
Company Name
PYDRO GMBH
Address
FRIEDRICH-BARNEWITZ-STR. 7 DE-18119 ROSTOCK-WARNEMÜNDE

View All Listings by this Company
Manufacturer:
PYDRO GMBH
Company Name
PYDRO GMBH
Address
FRIEDRICH-BARNEWITZ-STR. 7 DE-18119 ROSTOCK-WARNEMÜNDE

View All Listings by this Company

Print This Approval


#2306903

CMBE range of horizontal multistage centrifugal booster pumps with stainless steel bodies and impellers and EPDM ‘O’-rings. All models include an expansion vessel, non-return valve, pressure gauge and sensor on the outlet. Maximum working pressure 10.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2306903
Size:
CMBE1 & CMBE3: 1” BSPT (F) Inlet/Outlet. CMBE5: 1 ¼” BSPT (F) Inlet/1” BSPT (F) Outlet. CMBE10: 1 ½” BSPT (F) Inlet/Outlet.
Marking:
Grundfos and Grundfos logo, type, Model, P/N no. and technical info on adhesive label on end of motor housing.
Installation Requirements:
R001 R040
Expiry date:
30/06/2028
Model:
CMBE-XX1-XX2-I-U-C-X3-D-X4 Where: CMBE = Booster type - booster with integrated frequency inverter. XX1 = Rated flow rate [m³/h] @ 50Hz - 1, 3, 5 or 10. XX2 = Maximum head [m] - 44, 54, 62 or 93 (CMBE 1 = 44, CMBE 3 = 62 or 93, CMBE 5 = 62, CMBE 10 = 54). I = Materials in contact with liquid - Sleeve, Pump shaft, Impellers/chamber, 5-way valve: EN1.4301/AISI 304, Pressure manager: PP 30GF, Pressure tank: EPDM/steel/PP/Butyl. U = Supply Voltage [V] - 1 x 200-240 V, 50/60 Hz. C = Motor - High-efficiency motor with frequency converter (IP55). X3 = Main cable and plug options - A/B/C/D/E/H/G/J/O. D = Controller - Integrated frequency converter. X4 = Thread - A: Rp 1, B: Rp 1 1/4 or C: Rp 1 1/2.

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Country
Denmark
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval


#2305076

Range of vertical multistage pumps with either stainless-steel bodies (“N” versions) or cast iron bodies with a black electrodeposition coating (“G” versions), stainless-steel impellers, shaft and outer sleeve. Maximum working pressure: NKV32 & NKV45 models - 32.0 bar, NKV65 & NKV95 models - 25.0 bar. Max operating temperature: Stainless steel (“N” versions) - 100°C. Cast iron (“G” versions) - Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2305076
Size:
DN65 - DN100
Marking:
DAB Pumps Spa, serial number, model number, date of manufacture (DD/MM/YYYY) and pressure on data plate on body.
Installation Requirements:
R001 R415
Expiry date:
31/05/2028
Model:
Code example (EV range): NVK 30 /13 A B C D E F G H J K L M N. Where: NVK = Pump model 30 = Rated flow [m³/h] (varies: 30-95). /13 = No. of stages/impellers. (See model and stages below for more detail). A = No. of trimmed impellers, if "Empty" = none. B = Flange type: "F" - round. C = Materials: "G" - (cast iron/Stainless steel); "N" - (AISI316/EN1.4401). D = Motor power (kW x 10). E = Motor type: “Vacuum” (pump without motor), "T" - 3-phase; "M" - 1-phase. F = Frequency: "5" - 50Hz; "6" - 60Hz. G = No. of motor poles: "Empty" - 2 poles; "4" - 4 poles. H = Mechanical Seal: "B" (balanced). J = Elastomeric and mechanical seal material: E1 (SiC-Carbon Graphite-EPDM) or E2 (SiC-SiC-EPDM). K = “IE…” motor efficiency class IEC60034-30, where applicable, “Vacuum” (pump without motor). L = “Vacuum” standard version,“M” (oversized motor). M = "Vacuum” - standard version. N = Motor voltage, “Vacuum” (pump without motor). NKV 32: stage from 1 to 13 (50Hz) and from 1-1A to 8 (60Hz); NKV 45: stage from 1-1A to 13-2A (50Hz) and from 1-1A to 7 (60Hz); NKV 65: stage from 1-1A to 8 (50hz) and from 1-1A to 5-1A(60 hz); NKV 95: stage from 1-1A to 6 (50Hz) and from 1-1A to 4-2A (60Hz).

Approval Holder:
DAB PUMPS SPA
Company Name
DAB PUMPS SPA
Address
Via Marco Polo 14 Mestrino (PD)
Postcode
35035
Country
Italy
General Email
certifications@dwtgroup.com

View All Listings by this Company

Print This Approval


#2305078

Range of vertical multistage pumps with either stainless-steel bodies (“N” versions) or cast iron bodies with a black electrodeposition coating (“G” versions), stainless-steel impellers, shaft and outer sleeve. Maximum working pressure: FGV30, FGV45 - 32.0 bar, FGV65, FGV95 - 25.0 bar. Max operating temperature: Stainless steel (“N” versions) - 100°C. Cast iron (“G” versions) - Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2305078
Size:
DN65 - DN100
Marking:
Fourgroup, serial number, model number, date of manufacture (DD/MM/YYYY) and pressure on data plate on body. Flow arrow on body.
Installation Requirements:
R001 R415
Expiry date:
31/05/2028
Model:
FGV range. Code example (FGV range): FGV 30 /13 A B C D E F G H J K L M N. Where: FGV = Pump model FGV (EV = E-Tech “brand”). 30 = Rated flow [m³/h] (varies: 30-95). /13 = No. of stages/impellers. (See model and stages below for more detail). A = No. of trimmed impellers, if "Empty" = none. B = Flange type: "F" - round. C = Materials: "G" - (cast iron/Stainless steel); "N" - (AISI316/EN1.4401). D = Motor power (kW x 10). E = Motor type: “Vacuum” (pump without motor), "T" - 3-phase; "M" - 1-phase. F = Frequency: "5" - 50Hz; "6" - 60Hz. G = No. of motor poles: "Empty" - 2 poles; "4" - 4 poles. H = Mechanical Seal: "B" (balanced). J = Elastomeric and mechanical seal material: E1 (SiC-Carbon Graphite-EPDM) or E2 (SiC-SiC-EPDM). K = “IE…” motor efficiency class IEC60034-30, where applicable, “Vacuum” (pump without motor). L = “Vacuum” standard version,“M” (oversized motor). M = "Vacuum” - standard version. N = Motor voltage, “Vacuum” (pump without motor). FGV30: stage from 1 to 13 (50Hz) and from 1-1A to 8 (60Hz); FGV45: stage from 1-1A to 13-2A (50Hz) and from 1-1A to 7 (60Hz); FGV65: stage from 1-1A to 8 (50hz) and from 1-1A to 5-1A(60 hz); FGV95: stage from 1-1A to 6 (50Hz) and from 1-1A to 4-2A (60Hz).

Approval Holder:
FOURGROUP
Company Name
FOURGROUP
Address
via E. Fermi 8, 35020 Polverara (PD)
Country
Italy

View All Listings by this Company

Print This Approval


#2204361

Range of booster pumps with stainless steel bodies, plastic impellers, and NBR ‘O’-rings. The products incorporate a temperature sensor, pressure sensor, pressure vessel and a non-return valve integral to the pump chamber. Maximum working pressure 6.5 bar. Maximum operating temperature 75°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2204361
Size:
1” BSP (F)
Marking:
SPCO and model number other technical information on adhesive label on body.
Installation Requirements:
R001 R415
Expiry date:
30/04/2027
Model:
SMART PLUS 370-25-A, (370W), 25m (Rated Head), SMART PLUS 550-24-A, (550W), 24m (Rated Head), SMART PLUS 750-30-A, (750W), 30m (Rated Head), SMART PLUS 550-22-Z-A, (550W), 22m (Rated Head), SMART PLUS 750-28-Z-A, (750W), 28m (Rated Head), SMART PLUS 850-30-A, (850W), 65m (Rated Head).

Approval Holder:
Swiss Pump Company AG
Company Name
Swiss Pump Company AG
Address
Moosweg 36,3645 Thun - Gwatt
Country
Switzerland

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 321 of 885

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.