Tenant valve assemblies with a DZR brass body consisting of water meter manifold, servicing valve and a pressure reducing valve (adjustable between 1.0 and 6.0 bar). The inlet incorporates two approved check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3). Maximum working pressure 16.0 bar.
Range of manually operated balancing valves with bronze bodies, DZR brass disc and EPDM rubber 'O’-rings. Both models have test points. The F9506 models also have a drain point on the high-pressure test side. Maximum working pressure 25.0 bar. Maximum operating temperature 100°C.
Range of undercounter water chillers with a stainless-steel cooling tank including a drain outlet. Maximum working pressure 3.0 Bar. Maximum operating temperature 38°C.
‘G5 C’ command centre providing chilled (filtered) water via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The products are supplied with a filter cartridge. The inlet to the command centre incorporates two approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum inlet supply pressure 5.0 bar. Cold water use only.
‘G5 CS’ command centre providing chilled or chilled sparkling water (both filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The product incorporates a pressure reducing valve (adjustable outlet pressure between 2.25 and 2.75 bar) on the supply to the carbonator unit. The carbonator inlet incorporates a non-return valve. The product is supplied with a filter cartridge. The inlet to the command centre incorporates two approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum inlet supply pressure 5.0 bar. Cold water use only.
Range of combined isolation and drain off valves with brass bodies and EPDM O-rings. Maximum working pressure 16 Bar Maximum operating temperature 65°C
Non-metallic materials and components comply with BS6920 at 65°C
‘X086 Ceramic Dome’. Grey coloured, hydraulically pressed ceramic dome component. For use with water up to 23°C.
'Hilox 961'. Brown coloured, dry pressed ceramic material. For use with water up to 85°C.
'WHC1850'. White coloured, dry pressed ceramic disc. For use with water up to 85°C.
'Rubalit IS95 White'. White coloured, dry pressed ceramic disc component. For use with water up to 85°C.
'YJ-AL2O3 95%'. White coloured, dry pressed and sintered ceramic disc. For use with water up to 85°C.
'G52-06 Quick-drying type Black High Chlorinated Polyethylene Anticorrosive Coating'. Factory applied, black coloured polyethylene coating. Apply as per manufacturer's data sheet 'XYJSMS002', dated January 10th, 2023. Cure for 24 hours@25°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘NATZINC EP9015 SC PART A-BI.5431 Primer for use with HYDRALFUN AC BLEU PAM RAL5005-CZL8190 Coating’. Factory applied, dark blue coloured (once applied), powder coating for use with two-part epoxy primer. Mix parts A & B of primer in a 100:10 mass ratio and apply as per manufacturer’s TDS dated February 2024. Cure for 24 hrs at 20°C. Apply coating as per manufacturer’s TDS dated February 2024 and cure for 21 days at 20°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘PRIMER NATZINC EP9015 SC PART A’ Primer for use with ' HYDRALFUN AC BLEU PAM RAL5005-CZL8190 ' top-coat. Factory applied, blue coloured (once applied) primer and finish-coat. Mix base:hardener of primer in a 100:10 weight ratio and apply as per manufacturer’s TDS February 2024. Then apply top-coat as per manufacturer’s TDS February 2024. Cure for 21 days@23°C. For use with water up to 50°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'HYDRALFUN AC BLEU PAM RAL5005-CZL8190'. Factory applied, blue coloured acrylic paint. Apply as per manufacturer's TDS dated February 2024. Cure for 21 days@23°C. Between April 2024 and July 2024, the paint is for use with water up to 50°C. From August 2024 the paint is for use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'HYDRALFUN AC NOIR PAM - CZL8579'. Factory applied, black coloured acrylic paint. Apply as per manufacturer's TDS dated July 2018. Cure for 21 days@23°C. For use with water up to 60°C.
'Drincable'. Blue coloured, extruded, EPDM rubber electrical cable. Shore hardness 50. Tested in-radius size 0.90mm. For use with water up to 23°C. This approval is for complete cable, the blue coloured outer part being the water contact layer.
‘Drinkflex Aquarius 3G1, 3G1,5, 3G2,5, 3G4, 4G1, 4G1,5, 4G2,5, 4G4 & 4G6’ range of polyolefine cables. The cables have an extruded, blue coloured polyolefine outer (water contact) layer and are available with 3 or 4 internal cores. For use with water up to 23°C.
'Saudi Drip HDPE PE100 pipe'. Black coloured, extruded HDPE pipe. For use with water up to 60°C.
'Asrene SP4808'. White coloured, compression moulded HDPE material. For use with water up to 65°C.
Page 33 of 48
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.