'YJ-AL2O3 95%'. White coloured, dry pressed and sintered ceramic disc. For use with water up to 85°C.
'G52-06 Quick-drying type Black High Chlorinated Polyethylene Anticorrosive Coating'. Factory applied, black coloured polyethylene coating. Apply as per manufacturer's data sheet 'XYJSMS002', dated January 10th, 2023. Cure for 24 hours@25°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘NATZINC EP9015 SC PART A-BI.5431 Primer for use with HYDRALFUN AC BLEU PAM RAL5005-CZL8190 Coating’. Factory applied, dark blue coloured (once applied), powder coating for use with two-part epoxy primer. Mix parts A & B of primer in a 100:10 mass ratio and apply as per manufacturer’s TDS dated February 2024. Cure for 24 hrs at 20°C. Apply coating as per manufacturer’s TDS dated February 2024 and cure for 21 days at 20°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘PRIMER NATZINC EP9015 SC PART A’ Primer for use with ' HYDRALFUN AC BLEU PAM RAL5005-CZL8190 ' top-coat. Factory applied, blue coloured (once applied) primer and finish-coat. Mix base:hardener of primer in a 100:10 weight ratio and apply as per manufacturer’s TDS February 2024. Then apply top-coat as per manufacturer’s TDS February 2024. Cure for 21 days@23°C. For use with water up to 50°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'HYDRALFUN AC BLEU PAM RAL5005-CZL8190'. Factory applied, blue coloured acrylic paint. Apply as per manufacturer's TDS dated February 2024. Cure for 21 days@23°C. Between April 2024 and July 2024, the paint is for use with water up to 50°C. From August 2024 the paint is for use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'HYDRALFUN AC NOIR PAM - CZL8579'. Factory applied, black coloured acrylic paint. Apply as per manufacturer's TDS dated July 2018. Cure for 21 days@23°C. For use with water up to 60°C.
'Drincable'. Blue coloured, extruded, EPDM rubber electrical cable. Shore hardness 50. Tested in-radius size 0.90mm. For use with water up to 23°C. This approval is for complete cable, the blue coloured outer part being the water contact layer.
‘Drinkflex Aquarius 3G1, 3G1,5, 3G2,5, 3G4, 4G1, 4G1,5, 4G2,5, 4G4 & 4G6’ range of polyolefine cables. The cables have an extruded, blue coloured polyolefine outer (water contact) layer and are available with 3 or 4 internal cores. For use with water up to 23°C.
'Saudi Drip HDPE PE100 pipe'. Black coloured, extruded HDPE pipe. For use with water up to 60°C.
'Asrene SP4808'. White coloured, compression moulded HDPE material. For use with water up to 65°C.
‘G&B Fissaggi Gebofix PRO VE-SF SISMIK’. Site applied, two part, grey coloured (once mixed) anchor resin. The material consists of Part A (shiny white liquid) & Part B (shiny black liquid). Mix, apply and cure as per ‘full curing of dry base material’ which appears in manufacturer’s Technical Data Sheet ‘rev. 05/2022’, For use with water up to 60°C. For use only as a resin anchor having been tested at a reduced surface area to volume ratio of 1,000mm² per 1 litre of water.
`SW EPDM`. Black coloured, extruded, EPDM hose. Shore hardness 85. Tested in-radii sizes between 0.75mm & 1.70mm. For use with water up to 85°C.
'01/U70EP 'O' ring' with a tested in-radius size between 0.5mm & 3.5mm. In June 2024, the follow components were added to the approval: ‘01/U70EP Cylindrical Gasket’ with a tested in-radius size between 0.9mm & 1.25mm. ‘01/U70EP Membrane’ with a tested in-radius size between 2.1mm & 5.5mm. Black coloured, injection moulded EPDM components. Shore hardness 70 For use with water up to 85°C.
'EPDM-A-001'. Black coloured, compression moulded EPDM rubber material. Shore hardness 70. Tested in-radius size 1.1mm. For use with water up to 85°C.
‘Drei Bond 5204’. Yellow coloured anaerobic adhesive paste. For use with water up to 85°C. This product is to be applied and cured in strict accordance with the manufacturer's instructions.
Wall mounted electric heater, incorporate a manually operated push button valve controlling the flow and plastic strainer on the inlet. Maximum working pressure 10.0 bar. Maximum operating temperature 53°C. Cold supply only.
Range of single hole, single outlet (fixed) electronically controlled tap assemblies (stainless steel bodies), incorporating a solenoid valve controlling the flow which is actuated via an infra-red sensor. The spout outlet incorporates a plastic aerator. The product also incorporates an integral hand dryer. Maximum working pressure 8.0 Bar
Non-metallic materials and components comply with BS6920 at 43°C
Wall mounted single hole, single outlet (fixed) electronically controlled tap assemblies (stainless steel bodies), incorporating a solenoid valve controlling the flow which is actuated via an infra-red sensor. The spout outlet incorporates a plastic aerator. The product also incorporates an integral hand dryer. Maximum working pressure 8.0 Bar
Non-metallic materials and components comply with BS6920 at 43°C
Range of BS1212-4 (2016) float operated valves for WC flushing cisterns, bottom or side entry type with plastic or brass ½’’ BSP inlet. The inlet incorporates a strainer, Compact models incorporate a delay fill function. Maximum working pressure 10.0 bar. For use with cold water only.
Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 3.5 litres. The cistern is operated by an electronically controlled flush valve. The product also incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Page 33 of 48
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.