#2210903

Dual flush drop valve incorporating two push buttons that operate either full or reduced flush. The valve reduced flush assembly is adjustable to give different flush volumes. The valve incorporates an internal overflow (overflow can be fitted or blanked off). Cold water use only.

Section:
1305 Flushing Mechanisms
Section Subtitle:
WC. Except where specified, flushing valves within this section have only completed a limited number of the performance and endurance tests as stated in the "Regulators Specification for WC suites installed after 1st January 2001". The flush volume of valves within this section have not be verified by test. When installed in combination with a WC cistern and pan, further performance tests will be required.
WRAS Approval Number:
2210903
Size:
2” BSP Outlet
Marking:
Niagara, Dudley and TD moulded on top of valve.
Installation Requirements:
R001 R571 R581
Expiry date:
31/10/2027
Model:
DUDLEY NIAGARA MECHANICAL DUAL FLUSH VALVE - product code PSPOVN313348.
Product Images

Approval Holder:
Thomas Dudley Limited
Company Name
Thomas Dudley Limited
Postcode
DY1 4SJ
Country
United Kingdom
Phone
0121 530 7053
General Email
jcresswell@thomasdudley.co.uk

View All Listings by this Company
Manufacturer:
Thomas Dudley Limited
Company Name
Thomas Dudley Limited
Postcode
DY1 4SJ
Country
United Kingdom
Phone
0121 530 7053
General Email
jcresswell@thomasdudley.co.uk

View All Listings by this Company

Print This Approval


#2211007

Dual flush drop valve with ABS body and silicone seal. The valve is operated via a lever assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.

Section:
1305 Flushing Mechanisms
Section Subtitle:
WC. Except where specified, flushing valves within this section have only completed a limited number of the performance and endurance tests as stated in the "Regulators Specification for WC suites installed after 1st January 2001". The flush volume of valves within this section have not be verified by test. When installed in combination with a WC cistern and pan, further performance tests will be required.
WRAS Approval Number:
2211007
Size:
2” BSP (M)
Marking:
R&T on body.
Installation Requirements:
R001 R571 R581
Expiry date:
30/11/2027
Model:
A2432
Product Images

Approval Holder:
Xiamen R&T Plumbing Technology Co.,Ltd
Company Name
Xiamen R&T Plumbing Technology Co.,Ltd
Address
No.18, Houxiang Road Haicang District Xiamen
Postcode
361022
Country
China
Phone
86-0592-3959422
General Email
rt025@rtplumbing.com

View All Listings by this Company
Manufacturer:
Xiamen R&T Plumbing Technology Co.,Ltd
Company Name
Xiamen R&T Plumbing Technology Co.,Ltd
Address
No.18, Houxiang Road Haicang District Xiamen
Postcode
361022
Country
China
Phone
86-0592-3959422
General Email
rt025@rtplumbing.com

View All Listings by this Company

Print This Approval


#2206361

Range of heat exchangers connected to copper waste pipe, Where the waste is discharged down a “rotator” into a copper waste pipe, and potable water is returned to the shower/heating device via a copper double walled jacket around the copper waste pipe. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C

Section:
1350 Heat Exchangers
Size:
½” BSP (F)
Marking:
Manufacturer ( Builidng Product Distribution) Manufacturer address Type Category BPD Ltd Serial No. Model & other information on Adhesive label.
Installation Requirements:
R001
Expiry date:
30/06/2027
Model:
Showersave: QB1-21C QB1-16C QB1-12C QB1-21 Cyclone QB1-21 QB1-16 QB1-12 QB1-21D QB1-21D HE Models added June 2024 - maximum working pressure of 10.0 bar. QBI-2IXE QBI-I0XE
Product Images

Approval Holder:
BPD Limited
Company Name
BPD Limited
Address

View All Listings by this Company

Print This Approval


#2207038

Range of electric instantaneous water heaters. The DEX and DCX models incorporate a spherical ball valve on the inlet. The CEX and DEX models incorporate an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet incorporates a strainer. Maximum working pressure 10 bar (DEX models only) All other models open outlet. Maximum operating temperature: ES3/4/5 and Zip Hydrotap G4/G5 ranges – 65ºC. CEX, DEX and DCX ranges - 70°C.

Section:
1365 Heaters
Section Subtitle:
Electric instantaneous, open outlet, mains fed.
WRAS Approval Number:
2207038
Size:
ES, Zip HydroTap and CEX models - ½” BSP male inlet and outlet. DEX and DCX models- 3/8” BSP captive nut inlet and outlet that connects to a valve with a ½” BSP male inlet.
Marking:
Zip inline and Clage on front cover. Zip inline, model, Maximum temperature and pressure and technical information on label on body.
Installation Requirements:
R001 R040
Expiry date:
31/07/2027
Model:
ES3 ES4 ES6 CEX CEX-U DEX12 NEXT DCX NEXT ZIP HydroTap G4 & G5 booster
Product Images

Approval Holder:
Zip Heaters UK Ltd T/A Zip Water UK
Company Name
Zip Heaters UK Ltd T/A Zip Water UK
Address
Trafalgar House, Trafalgar Business Park, Dereham
Postcode
NR19 1JG
Country
United Kingdom
Phone
0345 600 5005
General Email
sebastian.ducker@zipwater.co.uk

View All Listings by this Company
Manufacturer:
Clage GmbH
Company Name
Clage GmbH
Address
PIROLWEG 1 5 21337 LUENEBURG GERMANY
General Email

View All Listings by this Company

Print This Approval


#2201345

Range of wall mounted, gas-fired, condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and a pressure relief valve set at 3.0 bar. The inlets to the domestic hot water and primary circuits each have a screwdriver operated angled spherical valve. Both include a ½” BSP (M) connection for a filling link. The Greenstar CDi models only are supplied with an integral charging link (CAB device) verified by test (suitable for backflow protection against Fluid Category 3). Maximum working pressure of the primary circuit is 2.5 bar. Maximum working pressure of the secondary circuit is 10.0 bar. Maximum operating temperature of primary circuit is 82°C. Maximum operating temperature of secondary circuit is 60°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2201345
Size:
Secondary: 15mm compression. Primary: 22mm compression.
Marking:
Worcester and Wocester logo on front cover. Worcester, Worcester logo, model number, pressure, temperature and other technical information on data label inside boiler. (Worcester is a brand of Bosch).
Installation Requirements:
R001 R360
Expiry date:
31/01/2027
Proviso:
Greenstar CDi models: Supplied with a filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999. Greenstar Si models: Not supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
7-733-600-056 Greenstar 36CDi Compact ErP, 7-733-600-059 Greenstar 36CDi Compact ErP LPG, 7-733-600-055 Greenstar 32CDi Compact ErP, 7-733-600-058 Greenstar 32CDi Compact ErP LPG, 7-733-600-054 Greenstar 28CDi Compact ErP, 7-733-600-057 Greenstar 28CDi Compact ErP LPG, 7-733-600-050 Greenstar 25Si Compact ErP, 7-733-600-051 Greenstar 25Si Compact ErP LPG, 7-733-600-052 Greenstar 30Si Compact ErP, 7-733-600-053 Greenstar 30Si Compact ErP LPG.
Product Images

Approval Holder:
Worcester Bosch
Company Name
Worcester Bosch
Address
Cotswold Way Warndon Worcester
Postcode
WR4 9SW
Country
United Kingdom
Phone
+44 1905 752761
General Email
ian.sharp@uk.bosch.com

View All Listings by this Company

Print This Approval


#2205321

Range of electric combination boilers providing heating and instantaneous hot water. The heating system incorporates an expansion vessel and pressure relief valve (set at 3.0 bar). The DHW inlet and outlet incorporate spherical servicing valves. Fittited with a CAB device keyless filling link, verifired by test, suitable for category 3 backlfow protection. Maximum working pressure on central heating circuit 2.5 bar & Domestic Hot Water 10bar. Maximum operating temperature 80°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2205321
Size:
15mm compression x 22mm compression.
Marking:
E.C.A on front casing. Manufacturer, address, model no, QR code and other technical information on side panel.
Installation Requirements:
R001 R140
Expiry date:
31/05/2027
Model:
8116270010 - Arceus/Cure plus/Electus EK 12 MT UK, 8116271010 - Arceus/Cure plus/Electus EK 15 MT UK, 8116272010 - Arceus/Cure plus/Electus EK 18 MT UK 8116273010 - Arceus/Cure plus/Electus EK 24 MT UK & 8116274010 - Arceus/Cure plus/Electus EK 27 MT UK
Product Images

Approval Holder:
Emas Makina Sanayi A.S.
Company Name
Emas Makina Sanayi A.S.
Address
Mustafa Kemal Blv. No:13 Keçiliköy Osb/Yunusemre Manisa
Postcode
45030
Country
Turkey
General Email
egecakmakci@emas.com.tr

View All Listings by this Company
Manufacturer:
Emas Makina Sanayi A.S.
Company Name
Emas Makina Sanayi A.S.
Address
Mustafa Kemal Blv. No:13 Keçiliköy Osb/Yunusemre Manisa
Postcode
45030
Country
Turkey
General Email
egecakmakci@emas.com.tr

View All Listings by this Company

Print This Approval


#2207350

Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2207350
Size:
Secondary: 15mm compression. Primary: 22mm compression.
Marking:
Ideal heating printed on front casing. Model and size printed on drop down door.
Installation Requirements:
R001 R140 R360
Expiry date:
31/07/2027
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
Logic Max Combi² C24 – UIN 228334, Logic Max Combi² C30 – UIN 228335, Logic Max Combi² C35 – UIN 228336, Logic + Combi² C24 – UIN 228329, Logic + Combi² C30 – UIN 228330, Logic + Combi² C35 – UIN 228331, Logic Combi² C24 – UIN 228307, Logic Combi² C30 – UIN 228308, Logic Combi² C35 – UIN 228309.

Approval Holder:
Ideal Boilers Ltd
Company Name
Ideal Boilers Ltd
Address
PO Box 103 National Avenue Hull East Yorkshire
Postcode
HU5 4JN
Country
United Kingdom
Phone
07775659359
General Email
ben.higinbotham@groupe-atlantic.co.uk

View All Listings by this Company
Manufacturer:
Ideal Boilers Ltd
Company Name
Ideal Boilers Ltd
Address
PO Box 103 National Avenue Hull East Yorkshire
Postcode
HU5 4JN
Country
United Kingdom
Phone
07775659359
General Email
ben.higinbotham@groupe-atlantic.co.uk

View All Listings by this Company

Print This Approval


#2207374

Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2207374
Size:
Secondary: 15mm compression. Primary: 22mm compression.
Marking:
Ideal heating printed on front casing. Model and size printed on drop down door.
Installation Requirements:
R001 R140 R360
Expiry date:
31/07/2027
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
INDEPENDENT COMBI² C24 INDEPENDENT COMBI² C30 INDEPENDENT COMBI² C35

Approval Holder:
Ideal Boilers Ltd
Company Name
Ideal Boilers Ltd
Address
PO Box 103 National Avenue Hull East Yorkshire
Postcode
HU5 4JN
Country
United Kingdom
Phone
07775659359
General Email
ben.higinbotham@groupe-atlantic.co.uk

View All Listings by this Company

Print This Approval


#2207375

Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2207375
Size:
Secondary: 15mm compression. Primary: 22mm compression.
Marking:
I-MINI² printed on front casing. Model and size printed on drop down door.
Installation Requirements:
R001 R140 R360
Expiry date:
31/07/2027
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
I-MINI²C24 I-MINI²C30 I-MINI²C35

Approval Holder:
Ideal Boilers Ltd
Company Name
Ideal Boilers Ltd
Address
PO Box 103 National Avenue Hull East Yorkshire
Postcode
HU5 4JN
Country
United Kingdom
Phone
07775659359
General Email
ben.higinbotham@groupe-atlantic.co.uk

View All Listings by this Company

Print This Approval


#2207373

Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2207373
Size:
Secondary: 15mm compression. Primary: 22mm compression.
Marking:
KESTON printed on front casing. Model and size printed on drop down door.
Installation Requirements:
R001 R140 R360
Expiry date:
31/07/2027
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
KESTON COMBI² C30 & KESTON COMBI² C35 COMBINATION BOILERS

Approval Holder:
Ideal Boilers Ltd
Company Name
Ideal Boilers Ltd
Address
PO Box 103 National Avenue Hull East Yorkshire
Postcode
HU5 4JN
Country
United Kingdom
Phone
07775659359
General Email
ben.higinbotham@groupe-atlantic.co.uk

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 33 of 96

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.