Range of wall mounted, bar type thermostatic shower mixer (chromium plated brass) Incorporating a quarter turn headwork controlling the flow with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets and shower outlet incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlets also incorporate stainless steel strainers. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Wall mounted thermostatic shower valve (chrome plated brass body), incorporating a non-rising spindle headwork controlling the flow. The temperature is controlled independently with a thermostatic cartridge, both using single lever operating members. The inlets incorporate flow regulators, plastic strainers and approved single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with a shower kit that consists of a shower handset, shower hose and riser rail assembly. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of thermal circulation valves with gunmetal bodies and EPDM ‘O’-rings. Models incorporate drain valves. Maximum operating pressure 16.0 bar. Maximum operating temperature 90°C.
Range of wall mounted thermostatic blending valves (chrome plated brass), incorporating a quarter turn ceramic disc or ceramic cartridge headworks (see models). The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button, with a variety of operating members. The inlets incorporate approved check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection with stainless-steel strainers. Maximum working pressure 5.0 Bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of wall mounted thermostatic shower valves, (chrome plated brass bodies). Models (EG1290 & EG1209002) incorporate a non-rising spindle headwork controlling the flow with a single lever operating member. Models (EG15092 & EG1509201) incorporate quarter turn ceramic disc headworks controlling the flow with single lever operating members. The temperature on all models is controlled by a thermostatic cartridge using a cross-top type operating member. The shower outlet connection incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 Bar Maximum operating temperature 65.0°C
Non-metallic materials and components comply with BS6920 at 65°C
Range of T-type thermostatic blending valves with chromium plated brass bodies. Temperature is controlled via a thermostatic cartridge. The inlets of all models except model 521308, 521324, 521314 and 521318 incorporate single check valve cartridges (verified by test - suitable for backflow protection against Fluid Category 2) and stainless-steel strainers. Compression fitting connection to be used with copper pipe EN1057 only. Maximum working pressure 10 bar. Maximum operating temperature 85°C except for models CA-100827 & CA-100828 both 60°C
Range of wall mounted thermostatic bar shower mixers (brass bodies – chrome plated or black finish) incorporating quarter turn ceramic disc headwork controlling the flow with cubed or dome type operating members. The temperature is controlled independently via a thermostatic cartridge cube or dome type operating members incorporating a manual override button. The inlets incorporate stainless steel strainers and approved check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 Bar
Non-metallic materials and components comply with BS6920 at 60°C
Wall mounted, concealed, thermostatic shower valve incorporating ceramic disc diverter headwork controlling the flow with a single lever operating member. The temperature is controlled independently via a thermostatic cartridge, with dome operating members that also incorporate a manual override button. The inlets incorporate a stainless steel strainers and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of butterfly valves with ductile iron bodies and discs (blue epoxy coated) and EPDM sealing rings. The valves are hand wheel operated. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 80°C
‘J9’ (wafer type) & ‘L9’ (lug type) ranges of butterfly valves with blue epoxy coated ductile iron (128xxx) or stainless steel bodies (628xxx), stainless steel discs and EPDM seats. The products are supplied with either a lever, gearbox (below DN250), electric or pneumatic actuating operating members. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of butterfly valves with ductile iron bodies (blue epoxy coating), EPDM seats and `O` rings. Gearbox and handwheel Maximum working pressure 16.0 bar. Maximum operating temperature 80°C.
Range of wafer, lugged and double bridge type butterfly valves with blue epoxy coated ductile iron bodies, stainless steel or blue epoxy coated ductile iron discs and EPDM seats. JMC 31300/71300/61300 and PAR W/L/DF.112 models have stainless steel discs (DN50 to 250: ASTM CF3 M (1.4409) DN>250 ASTM CF8M (1.4408)); all other models have blue epoxy coated ductile iron discs. All valves are bare shaft without an operating member. Maximum working pressure 25.0 bar. Maximum operating temperature: JMC 31V00/71V00/61V00, PAR W/L/DF.P07 and PAR W/L/DF.112 models are 50°C. JMC 31W00/71W00/61W00 and PAR W/L/DF.P08 models are cold water use only.
Range of flanged butterfly valves incorporating blue epoxy coated ductile iron bodies and discs with EPDM rubber seats. Models incorporate hand wheel operating members. Maximum working pressure 16.0 Bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of handwheel & gear operated butterfly valves with blue epoxy coated ductile iron bodies and discs and EPDM rubber seat. Maximum working pressure 16.0 bar. Cold water use only. Maximum operating temperature 85°C (from Sept 2021)
Range of concealed two way & three way ceramic disc diverters, (brass bodies – various trim sets and operating members). Maximum working pressure: 10.0 Bar
Range of manual diverter valves with chrome plated brass bodies. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of spring-loaded resilient trim, non-return valves with blue epoxy coated ductile iron bodies, stainless steel discs and EPDM seals. Maximum working pressure 16.0 bar. Maximum operating temperature 80°C.
Range of non return valves with bronze bodies and discs, and an EPDM washer. Maximum working pressure 16 bar. Maximum operating temperature 85°C.
Range of in-line, adjustable pressure reducing valves, with a DZR brass body. The product incorporates two approved check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3) and a shut off valve. Maximum working pressure 16 Bar Maximum outlet pressure between 1.5 bar and 6.0 bar.
Non-metallic materials and components comply with BS6920 at 40°C
Range of pressure reducing valves with DZR brass bodies. The valves are adjustable in the range of 1.5 bar - 6.0 bar. Stainless steel strainer Maximum working pressure 16.0 bar. Maximum operating temperature 80°C.
Page 318 of 566
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.