Single hole, single outlet (swivel) combination tap assembly (chrome plated brass), incorporating quarter turn ceramic disk headwork’s with single lever operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chrome plated brass), incorporating non-rising spindle headworks with dome operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) incorporating a ceramic cartridge headwork controlling the hot and cold flow. MAL models incorporate a quarter turn ceramic disc headwork to control a filtered water supply. The spout outlets incorporate a plastic aerator. The inlets incorporate a check valve cartridge verified by test (suitable for backflow protection against Fluid Category 2). Maximum working pressure 5.0 bar. Maximum operating temperature 60ºC.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) with ceramic cartridge headworks and single lever operating members. The discharge is via the hand spray outlet or the infra-red controlled outlet on the swivel arm. The cold Inlet has a single check valve assembly (suitable for protection against fluid category 2 backflow). The spouts incorporate a plastic aerator. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly with a brass body (chromium plated), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet is a waterfall design. The inlets incorporate plastic flow restrictors. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated brass). Models 91742, 95660 incorporate a non-rising spindle headwork with dome type operating members. Model 21775 incorporate a non-rising spindle headwork with cross top operating members. Model 77174 incorporate a quarter turn ceramic disc headwork with single lever operating members. The fitting incorporates a manual diverter to the shower outlet The spout outlet incorporates a plastic flow straightener and the products are supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of two hole, metal single outlet (fixed) combination tap assemblies (various finishes). Incorporating either quarter turn ceramic disc or non-rising headwork with various operating members and a self-cancelling diverter to shower outlet. The spout outlets incorporate a plastic flow straightener and the product is supplied with plastic or metal backnuts, hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet, (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts, shower hose and handset. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Range of two hole, single outlet (swivel) combination tap assemblies (chrome plated brass) incorporating quarter turn ceramic disk headworks and lever operating members. The spout outlet incorporates a plastic flow straightener. Supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet swivel combination tap assembly (chrome plated brass), incorporating non-rising spindle headworks with dome operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (swivel) combination tap assembly (chrome plated brass) incorporating non rising spindle headworks with cross top operating members. The spout outlet incorporates a plastic flow straightener. Supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two-hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn rising spindle headworks with single lever operating members. The S8215AA model is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC.
Range of deck mounted thermostatic shower mixers with brass bodies (chrome plated), incorporating ceramic disc headworks with dome type operating members controlling the flow and a lockable self-cancelling diverter to shower outlet. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member that also incorporates a manual override button. Spout outlet incorporates a plastic flow straightener. Both inlets incorporate a single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection) and stainless-steel strainers. Model DYN106 is supplied with a shower hose and shower handset, all other models are supplied with a shower hose, shower handset, riser rail and soap dish. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies (brass body with various finishes) incorporating quarter turn ceramic discs. No operating members supplied. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Three hole, single outlet (swivel) combination tap assembly with brass body (various finishes) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted (swivel) spout outlets with chromium plated brass bodies, EDPM ‘O’-rings and a plastic flow straightener. DJ suffix models have a double swivel arm. Maximum operating temperature 65°C.
Range of brass compression fittings for use with copper pipe manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of capillary end feed bronze fittings for use with copper tube (manufactured to BS EN 1057). 15mm – 54mm fittings have a maximum working pressure of 25.0 bar. 67mm – 108mm fittings have a maximum working pressure of 16.0 bar. Maximum operating temperature 100°C.
Dual flush, WC outlet valves. The valves are operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
Range of WC dual flush drop valve with plastic body silicone rubber seal and NBR rubber ‘O’-ring. The valve is operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
Range of WC dual flush drop valve with plastic body silicone rubber seal and NBR rubber ‘O’-ring. The valve is operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water only.
Range of WC dual flush drop valve with plastic body silicone rubber seal and NBR rubber ‘O’-ring. The valve is operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.
Copper heat transformer. Maximum working pressure 11.0 bar. Maximum operating temperature 95°C.
Range of domestic hot water units incorporating instantaneous or semi-instantaneous plate heat exchanger assemblies. The product incorporates a motorised control valve, managed primary and secondary pumps (see model), and a drain valve on both circuits. Maximum working pressures: 10.0 bar primary, 9.5 bar secondary. Maximum operating temperatures: 110°C primary, 85°C secondary.
Ranges of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system incorporating an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both domestic hot water and primary are controlled via spherical valves. Products are supplied with a rigid filling loop or keyless filling link. Maximum working pressure of the primary circuit is 2.5 bar & maximum supply pressure of the secondary circuit is 8.0 bar. Cold water supply only. Maximum operating temperature 95°C.
Q4000 range of water meters incorporating stainless steel bodies, FKM rubber gasket and grey epoxy resin liner. Maximum working pressure 16.0 bar. Cold water use only.
Screw down pattern, angled solation valve with a dome type operating member, DZR brass body and an EPDM gasket and ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of 2,3 or 4 way manifolds incorporating a nickel plated brass body with non-rising spindle stop valves. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of shower outlet elbows with brass bodies (chrome plated,with exception of model 27.076.LS0). Some models incorporate a shower handset holder. The outlet incorporates a check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Intelligent water assist valve consisting of a motorised quarter turn shut off valve which operates in the event a leak on the supply pipe to which it is fitted. Maximum working pressure 10 bar. Cold water use only.
Range of in-line flow sensors with a plastic body, turbine and impeller case. Maximum working pressure 25.0 bar. Cold water use only.
Range of compact wall outlet assemblies with plastic bodies (chromium plated) and EPDM ‘O’-rings. Maximum working pressure 5.0 bar. Maximum operating temperature 55°C.
Plug with nylon body and stainless steel shaft. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Tap outlet with a silicone body. Maximum operating temperature 100°C.
Range of black plastic bodied multistage, self or manually primed, high pressure centrifugal pumps with a stainless steel outer casing, plastic impellors, EPDM seals and ‘O’-rings. Maximum working pressure 8.0 bar. Cold water use only.
MBC 12-22WM & MBC 12-28WM models are wall mounted mains supply booster sets. They are supplied with two spherical isolation valves, a spherical bypass valve and two single check valve assemblies (suitable for backflow protection against Fluid Category 2). The check valve assemblies are to be installed in accordance with the manufacturers instructions, one upstream of the pump inlet and one after the bypass valve. The booster pump incorporates a plastic strainer on the inlet and a plastic flow regulator on the outlet and is housed within a wall mounted cabinet. MJ3 VM & MJ3 HM models are mains supply booster sets intended to be mounted on an expansion vessel (not supplied as part of the approval). They comprise of a pump, a suction and discharge manifold with bypass arrangement, and a spherical bypass valve which incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The booster pump incorporates a plastic strainer on the inlet and a plastic flow regulator on the outlet. Maximum working pressure 6.0 bar. Cold water use only.
Range of inline circulating pumps with bronze bodies, plastic impeller and EPDM rubber seals. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Range of rotary vane (positive displacement) pumps with stainless steel bodies. Maximum working pressure 18.0 bar. Cold water use only.
Range of booster pumps with plastic bodies and impellers, EPDM ‘O’-rings and stainless steel inlet manifolds. The product incorporates a non-return valve. The ESYBOX MAX single models are also supplied with an optional 2” BSP (M) x 1¼” BSP (F) plastic inlet adaptor. Maximum working pressure 12.0 bar. Cold water use only.
Multistage, vertical booster pumps with a brass body and stainless steel pump housing, stainless steel impellers and EPDM ‘O’-rings. The 41782 (MV90 4M VSD) model includes a pressure transducer. Maximum working pressure 6.0 bar. Cold water use only.
Range of multistage centrifugal pumps with stainless steel (AISI 304) bodies and impellers, and EPDM ‘O’-rings. Maximum working pressure 12.0 bar. Maximum operating temperature 90°C.
Range of magnetic drive volumetric rotary vane pumps with a plastic housing and built-in relief valve. Maximum working pressure: 22 series models - 20.0 bar, 20 series models - 14.0 bar. Cold water use only.
Range of multistage centrifugal pumps with stainless steel bodies and impellers, and EPDM ‘O’-rings. Maximum operating pressure 11.0 bar. Maximum working temperature 90°C.
Range of pump units with plastic bodies and impellers, EPDM ‘O’-rings, expansion vessel with an EPDM membrane and a carbon graphite/ceramic/NBR shaft seal (bt-ar 13 bx 4ff xp). Each pump inlet incorporates a non-return valve. Single versions are standalone pumps, twin versions also include stainless steel manifolds. Maximum working pressure 10.0 bar. Cold water use only.
Range of shower arms and brackets with brass bodies (various finishes). Shower brackets incorporate single check valves cartridge, however the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Maximum operating temperature 85°C.
Range of shower handsets with chromium plated plastic bodies. Maximum operating temperature 75°C.
Range of shower handsets incorporating chromium plated plastic or chromium plated brass bodies (see model). Inlets incorporate a plastic flow regulator. Maximum operating temperature 60°C.
Range of shower outlet with chromium plated bodies with check valves fitted at the inlets however, the complete products have not been fully tested to demonstrate they provide backflow prevention. Maximum operating temperature 70°C. Open outlet use only.
Range of overhead shower outlets incorporating brass bodies (chrome plated) and EPDM gaskets. Inlets have stainless filters incorporated within a ball joint. Maximum operating temperature 85°C
Page 31 of 225
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.