Multi-layer hose incorporating a PVC inner layer and EPDM ‘O’-rings. Maximum operating temperature is 65°C.
Range of shower hoses incorporating stainless steel interlocking outer with PVC inner liner or PVC outer and PVC inner liner (see model). Maximum operating temperature 65°C.
Range of stainless steel or nylon braided, PEX lined flexible hose assemblies available in a range of end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Range of stainless steel braided, EPDM lined flexible hose assemblies available in a range of end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Mitsubishi Electric ‘EHPT20Q – VM2EA’ stainless steel unvented primary thermal store cylinder unit. An inline booster heater is also fitted into the primary circuit. The cylinder is fitted with two pressure relief valves set at 3.0 bar. Heat is transferred from the stored primary water to the secondary water circuit via a plate heat exchanger which provides instantaneous hot water. The primary thermal storage cylinder is to be filled by the use of the supplied temporary filling loop assembly, which consistd of a stainless steel braided EPDM lined flexible hose, a lever operated brass spherical valve and a DZR brass double check valve assembly (suitable for backflow protection against Fluid Category 3) that incorporates a lever operated spherical valve. A primary expansion vessel is supplied to accommodate the expansion of the primary water when heated. An automatic air vent is fitted to the top of the thermal store. The product is supplied with a tundish. Maximum working pressure: Primary circuit 2.5 bar, Secondary circuit 10.0 bar. Maximum operating temperature: Primary circuit 72°C, Secondary circuit 70°C.
SSB, SSI SST range of stainless steel unvented cylinders provided with an unvented kit supplied with cylinders containing a temperature and pressure reducing valve set at 3.0 bar and an expansion vessel and single check valve (suitable for fluid category 2) . Available as storage tank, indirect or twin coil. Maximum working pressure of the cylinder 6.0 bar, maximum working pressure of the coil or coils 12.0 bar. Maximum operating temperature 95°C.
Range of domestic stainless steel indirect unvented hot water storage cylinder incorporating a stainless steel coil for connection to a heat pump circuit. The secondary circuit is factory fitted with a temperature and pressure relief valve (10 bar and 92°C) and an Incoloy immersion heater and magnesium sacrificial anode. Maximum working pressure: Secondary circuit 9.5 bar. Maximum operating temperature 95°C.
Range of wall mounted, concealed, thermostatic shower blending valves with brass bodies and trim sets (various finishes). The temperature is controlled via a thermostatic cartridge with a cross top or single lever operating member. The inlets incorporate an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, exposed, bar type thermostatic shower mixers (chromium plated brass) with a 2-way ceramic disc diverter controlling the flow to either shower outlet. Temperature is controlled independently via a thermostatic cartridge which incorporates a manual override button. The S06 model has dome type operating members and the S15-2 model has cube type operating members. The inlets incorporate a stainless-steel strainer and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of wall mounted, concealed, thermostatic mixing vales with brass bodies and chrome plated trim sets, incorporating one or two quarter turn ceramic disc headworks with various operating members (see models). Temperature is controlled independently via a thermostatic cartridge with various operating members (see model) which incorporates a manual override button. Both inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Maximum operating temperature 85°C.
Range of water filters cartridges with plastic bodies and either carbon block or activated carbon filter media. Maximum working pressure 8.6 bar. Maximum operating temperature 38°C.
Wall mounted exposed thermostatic shower valve incorporating a brass body (various finishes), quarter turn ceramic disc headwork with single lever operating members and manual diverter to shower outlet. The temperature is controlled independently via a thermostatic cartridge with cross top type operating member. The inlets incorporate a single check valve cartridge (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection). The product is supplied with an overhead shower, shower handset, riser rail and shower hose. Maximum working pressure 5.0 bar Maximum operating temperature 60°C.
Wall mounted thermostatic bar shower valve, riser rail, shower handset, shower hose and overhead shower outlet. The valve incorporates a brass body (chrome plated) and ceramic disc headwork with dome type operating member which controls and diverts the flow between the two shower outlets. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. The inlets incorporate stainless steel filters and a single check valve cartridge however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted thermostatic blending valve (chrome plated brass) incorporating a quarter turn ceramic disc headwork with dome type operating members. The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button. The inlets incorporate approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature is 60°C.
Range of wafer and lugged type, concentric butterfly valves with epoxy coated cast iron bodies, austenitic steel discs and EPDM seats. Maximum working pressure 16.0 bar. Cold water use only.


Range of butterfly valves incorporating blue epoxy coated ductile iron bodies & wedges and EPDM sealing gasket. The closing mechanism is controlled by a hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85˚C.
Range of lug type butterfly valves incorporating blue epoxy coated cast iron bodies, stainless steel discs, EPDM seats and lever type operating member. Maximum working pressure 16.0 bar (models 2108 12, 2108 13 and 2108 14). Maximum working pressure 10.0 bar (models 210816 and 2108 18). Maximum operating temperature 100°C.
Range of shower bars with brass bodies (various finishes), incorporating a manual diverter with cube or dome type operating members, which diverts between an overhead shower and a shower hose and handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
2-way ceramic disc diverter with a plastic body, NBR ‘O’-rings and silicone seals. For insertion into specifically dimensioned bores. Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Range of wall mounted, concealed flow control valves with brass bodies, incorporating either one or two quarter turn ceramic disc headworks with single lever operating members. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Page 26 of 522
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.