Directory Search Results

Print List

#2104928

Range of pillar taps (chrorme plated brass) with ¼ turn ceramic disc headworks and lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
1800 Taps
Section Subtitle:
Pillar tap(s).
WRAS Approval Number:
2104928
Size:
3/4” BSP male
Marking:
Bristan on the operating member
Installation Requirements:
R001 R005
Expiry date:
30/04/2026
Model:
RP3 OR ¾ C

Approval Holder:
Bristan Group Ltd.
Company Name
Bristan Group Ltd.
Address
Birch Coppice Business Park Dorden Tamworth
Postcode
B78 1SG
Country
Staffs
Phone
01827 254144
General Email
hmistry@bristan.com

View All Listings by this Company

Print This Approval


#2103041

Ultraflow ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2103041
Note:
Expansion vessels should be installed in the vertical orientation and located so that the length of the connecting pipework is kept to a minimum.
Size:
22mm compression (Inlet Manifold)
Marking:
Ultraflow on front, technical information on adhesive label on body.
Installation Requirements:
R001 R140 R360
Expiry date:
31/03/2026
Proviso:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°c and 45°c.
Model:
UD90 - ULTRAFLOW 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UD120 - ULTRAFLOW 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. UD150 – ULTRAFLOW 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UD170 – ULTRAFLOW 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. UD200 – ULTRAFLOW 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UD250 – ULTRAFLOW 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UD300 – ULTRAFLOW 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UI90-ULTRAFLOW 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UI120 - ULTRAFLOW 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UI150 - ULTRAFLOW 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UI170 - ULTRAFLOW 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UI200 - ULTRAFLOW 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UI250 - ULTRAFLOW 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UI300 - ULTRAFLOW 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UWD170 -ULTRAFLOW 170 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER UWD200 -ULTRAFLOW 200 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER UWD250 -ULTRAFLOW 250 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER UWD300 -ULTRAFLOW 300 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER UWI170 ULTRAFLOW 170 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER UWI200 ULTRAFLOW 200 NDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER UWI250 ULTRAFLOW 250 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER UWI300 ULTRAFLOW 300 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER UDS60-ULTRAFLOW SLIM 60 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. UDS90-ULTRAFLOW SLIM 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UDS120-ULTRAFLOW SLIM 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UDS150D-ULTRAFLOW SLIM 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UDS170D-ULTRAFLOW SLIM 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UDS200D-ULTRAFLOW SLIM 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. UIS60-ULTRAFLOW SLIM 60 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UIS90-ULTRAFLOW SLIM 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UIS120-ULTRAFLOW SLIM 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UIS150-ULTRAFLOW SLIM 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UIS170-ULTRAFLOW SLIM 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UIS200-ULTRAFLOW SLIM 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER

Approval Holder:
L & M (HEATING) SUPPLIES LTD.
Company Name
L & M (HEATING) SUPPLIES LTD.
Address
103 LOCKFIELD AVENUE ENFIELD, ENFIELD, MIDDLESEX
Postcode
EN3 7PY

View All Listings by this Company

Print This Approval


#2102554

'Silvina Grease'. Off-white coloured (opaque) silicone grease. Apply as per manufacturer's instructions. For use with water up to 65°C.

Section:
5160 Lubricants
Expiry date:
28/02/2026

Approval Holder:
Global Lubricants
Company Name
Global Lubricants
Address
Goldcrest Estate, Whitehall Road, Great Bridge, Tipton
Postcode
DY4 7JT

View All Listings by this Company

Print This Approval


#2109073

BS1212-4 (2016) compact type float operated valve for WC flushing cisterns, side entry type. The inlet incorporates a plastic flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2075 Float Operated Inlet Valve
Section Subtitle:
Can be used to achieve a recognised air gap arrangement, providing it meets the appropriate backflow requirements. Suitable for use in a WC suite, provided it forms an arrangement which meets the requirements of Type AUK1 air gap and an appropriate WC performance specification.
WRAS Approval Number:
2109073
Size:
½” BSP (M) 3/8” BSP (M)
Marking:
UNISANI, BS1212-4 & model on body
Installation Requirements:
R001 R550
Expiry date:
30/09/2026
Model:
BWA1200

Approval Holder:
UNISANI (XIAMEN) TECHNOLOGY CO., LTD
Company Name
UNISANI (XIAMEN) TECHNOLOGY CO., LTD
Address
Unit 1204, No.496, Xinglinwan Road, Jimei District, Xiamen
Country
China

View All Listings by this Company

Print This Approval


#2111070

Range of concealed WC flushing cisterns with a side entry BS 1212-4(2016) float operated inlet valve providing a type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two button assembly for a 6 or 3 litre flush volume. The cistern incorporates a servicing valve and a stainless-steel braided EPDM lined flexible hose assembly installed prior to the inlet valve. Maximum working pressure 10.0 Bar, Cold Water use only

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
2111070
Size:
1/2" BSP (M)
Marking:
UNISANI, model number and 6l mark inside cistern.
Installation Requirements:
R001 R556
Expiry date:
30/11/2026
Model:
BW336-F & BW336

Approval Holder:
UNISANI (XIAMEN) TECHNOLOGY CO., LTD
Company Name
UNISANI (XIAMEN) TECHNOLOGY CO., LTD
Address
Unit 1204, No.496, Xinglinwan Road, Jimei District, Xiamen
Country
China

View All Listings by this Company

Print This Approval


#2112372

Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
2112372
Size:
½” BSP (M)
Marking:
Duravit on adhesive label bon body Duravit on flush plate Duravit, date of manufacture YYYY & Model on adhesive label inside cistern 6L waterline on casing within cistern
Installation Requirements:
R001 R556 R571
Expiry date:
31/12/2026
Model:
Durasystem range WD1034000080 WD1029000080

Approval Holder:
Duravit UK Ltd.
Company Name
Duravit UK Ltd.
Address
Unit 7 Stratus Park Brudenell Drive Brinklow Milton Keynes
Postcode
MK10 0DE

View All Listings by this Company

Print This Approval


#2112373

Jet range of water meters with brass blue epoxy coated bodies and EPDM rubber ‘O’-rings. Maximum working pressure16.0 bar. Maximum operating temperature 85°C.

Section:
1505 Water Meters
Size:
see model
Marking:
JET, WRAS and other technical info on dial.
Installation Requirements:
R001 R120
Expiry date:
31/12/2026
Model:
¾” BSP (M) 172033 JET NON PULSED COLD WATER METER 15 FTG 172035 JET PULSED COLD WATER METER 15 FTG 172041 JET PULSED HOT WATER METER 15 FTG 1” BSP (M) 172034 JET NON PULSED COLD WATER METER 20 FTG 172036 JET PULSED COLD WATER METER 20 FTG 172042 JET PULSED HOT WATER METER 20 FTG 1 ¼” BSP (M) 172037 JET PULSED COLD WATER METER 25 FTG 172043 JET PULSED HOT WATER METER 20 FTG 1 ½” BSP (M) 171038 JET PULSED COLD WATER METER 32 FTG 172044 JET PULSED COLD WATER METER 20 FTG 2” BSP (M) 172039 JET PULSED COLD WATER METER 32 FTG 172045 JET PULSED COLD WATER METER 20 FTG 2 ½” BSP (M) 172040 JET PULSED COLD WATER METER 32 FTG 172046 JET PULSED COLD WATER METER 20 FTG

Approval Holder:
Wolseley UK Ltd.
Company Name
Wolseley UK Ltd.
Address
2 Kingmaker Court, Warwick Technology Park, Warwick
Postcode
CV34 6DY
Country
United Kingdom
Phone
01926705792
General Email
martin.lister@wolseley.co.uk

View All Listings by this Company

Print This Approval


#2112068

Range of plastic shower handsets (various finishes). Maximum operating temperature 75°C.

Section:
1650 Shower Outlets
Section Subtitle:
Shower head(s) and/or shower handset(s).
WRAS Approval Number:
2112068
Note:
Open outlet use only.
Size:
½” BSP (M)
Marking:
HAND100 C - Bristan on handset HAND100 CC - Cascade (Brand of Bristan) on handset
Installation Requirements:
R001 R040
Expiry date:
31/12/2026
Model:
HAND100 C & HAND100 CC – ½” MALE BSP INLET

Approval Holder:
Bristan Group Ltd.
Company Name
Bristan Group Ltd.
Address
Birch Coppice Business Park Dorden Tamworth
Postcode
B78 1SG
Country
Staffs
Phone
01827 254144
General Email
hmistry@bristan.com

View All Listings by this Company

Print This Approval


#2111071

Range of Y type strainers with blue epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C

Section:
1715 Strainers
Size:
DN50 up DN400 flanged inlet and outlet
Marking:
Oventrop, size and pressure on data plate on body. Size, pressure and flow arrow on body.
Installation Requirements:
R001
Expiry date:
30/11/2026
Model:
166 10 SERIES

Approval Holder:
Oventrop GmbH & Co KG
Company Name
Oventrop GmbH & Co KG
Address
Paul-Oventrop-Strasse 1, 59939 Olsberg
Country
Germany

View All Listings by this Company

Print This Approval


#2110147

Range of pressfit connection spherical valves incorporating DZR brass bodies, PTFE seat and packing, NBR ‘O’-rings and various operating members: lever, lever lockable, T-handle and butterfly. For use with copper pipe (manufactured to BS EN 1057), stainless steel pipe (manufactured to BS EN 10312) and carbon steel pipe (ISO 4200 Groupe 1 Series 3). Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.

Section:
2260 Valves
Section Subtitle:
Spherical, metal.
WRAS Approval Number:
2110147
Size:
See model.
Marking:
RP logo & WRAS on operating member DN, PN, CR and size on valve body.
Installation Requirements:
R001
Expiry date:
31/10/2026
Model:
LPBV015B: 15MM X 15MM. LPBV022B: 22MM X 22MM. LPBV028B: 28MM X 28MM. LPBV035B: 35MM X 35MM. LPBV042B: 42MM X 42MM. LPBV054B: 54MM X 54MM.

Approval Holder:
Rapid Press Fittings Ltd
Company Name
Rapid Press Fittings Ltd
Address
2 Penrod Way Heysham
Postcode
LA3 2UZ

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 215 of 350

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.