#240602719

Wall hung concealed WC flushing cistern with a BS 1212-4 float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a push button assembly. Maximum working pressure - 10 Bar. Cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
240602719
Size:
½” BSP (M)
Marking:
Flume on body, 6 litre line inside cistern.
Installation Requirements:
R001 R280 R556 R581
Expiry date:
30/06/2029
Model:
AB770

Approval Holder:
Toolstation Ltd.
Company Name
Toolstation Ltd.
Address
Travis Perkins PLC Ryehill House Rye Hill Close Lodge Farm Industrial Estate Northampton
Postcode
NN5 7UA
Country
United Kingdom
Phone
07392109053
General Email
benjamin.cockerill@travisperkins.co.uk

View All Listings by this Company

Print This Approval


#250701701

Low Level WC suites incorporating a frame mounted ceramic pan that is fitted with a washing & drying arrangement which is fed via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The cistern incorporates a side entry BS1212/4 float operated inlet valve and provides a type `AB` air gap. The drop type flush valve provides a single flush of 6 litres and is operated by elbow push button levers that are designed into the front of the cistern cover. Maximum working pressure 10.0 bar. Cold water use only

Section:
2043 WC incorporates a bidet or washing function
Section Subtitle:
Incorporates a Type AB air gap backflow prevention arrangement upstream of washing and flushing function. The product incorporates a fluid category 5 backflow prevention arrangement.
WRAS Approval Number:
250701701
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (M)
Marking:
Clos-O-Mat on underside of WC seat lid and on data plate. Water level is marked 6 Lit on the inner wall of cistern.
Installation Requirements:
R001 R280 R574
Expiry date:
31/07/2030
Model:
Clos-O-Mat Palma Vita Clos-O-Mat Lima Vita

Approval Holder:
Clos-o-Mat (Great Britain) Ltd.
Company Name
Clos-o-Mat (Great Britain) Ltd.
Address
Building 1 Brooklands Place, Brooklands Road, Sale
Postcode
M33 3SD
Country
Cheshire
Phone
+44 (0) 161 969 1199
General Email
info@clos-o-mat.com

View All Listings by this Company
Manufacturer:
Clos-o-Mat (Great Britain) Ltd.
Company Name
Clos-o-Mat (Great Britain) Ltd.
Address
Building 1 Brooklands Place, Brooklands Road, Sale
Postcode
M33 3SD
Country
Cheshire
Phone
+44 (0) 161 969 1199
General Email
info@clos-o-mat.com

View All Listings by this Company

Print This Approval


#250715311

Section:
0685 Combination Tap Assembly
Description:
A Tap(s) with a non-touch method of flow control incorporating temperature control.
Deck Mounted. Activated via an infra-red sensor. Capable of achieving AUK3 Tap Gap.
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Installation Requirements:
R001 R006 R010
Expiry date:
31/07/2030

Product IdentificationSurface finishInlet DimensionMax Wrk. PressureMax Op. Temp.MarkingMarking LocationAll metals in the water pathway are on the 4msi positive listHeadworkFixing TypeSpout Outlet Includes
OASISBMChrome1/2" BSP (F)8 bar65 °CUtopiaBodyNoSolenoidNot ApplicableAerator

Approval Holder:
Utopia Bath & Kitchen General Trading LLC
Company Name
Utopia Bath & Kitchen General Trading LLC
Address
Office 9-11, Mohd Abdulrahman Al Bahar, Building Salahuddin Street, PO Box 251735 Dubai
Country
United Arab Emirates

View All Listings by this Company
Manufacturers:
ZHEJIANG VOLONG SANITARY WARES CO,LTD.

Print This Approval


#250504028

Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies (chrome plated brass) bodies. The flow is controlled via a solenoid valve activated via an infra-red sensor. The temperature is controlled independently via a thermostatic cartridge. The products incorporate approved check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlets incorporate a stainless-steel strainer. The products are supplied with spherical valves for both inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.

Section:
0685 Combination Tap Assembly
Section Subtitle:
Tap(s) with a non-touch method of flow control incorporating temperature control.
WRAS Approval Number:
250504028
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” Male BSP.
Marking:
IDRAL on operating member. Model number and date (WW/YY) on underside of tap.
Installation Requirements:
R001 R010 R040
Expiry date:
31/05/2030
Model:
09125/3R - WALL MOUNTED TAP (MAINS OPERATED) I90H1-01000 - WALL MOUNTED REMOVABLE SPOUT TAP (MAINS OPERATED) I90H1-00000 - WALL MOUNTED REMOVABLE SPOUT TAP (BATTERY OPERATED) 09125/3 - WALL MOUNTED TAP (BATTERY OPERATED)

Approval Holder:
Idral S.p.A.
Company Name
Idral S.p.A.
Address
Via Isei, 8/10 - I-28010 Gargallo (NO)
Country
Italy
Phone
+39 0322 912017

View All Listings by this Company

Print This Approval


#251002002

Range of combined bath fillers and overflow waste assemblies with plastic bodies (various finishes). The outlet incorporates a plastic aerator. The products are supplied with a cable operated pop-up waste. Maximum operating temperature 60°C.

Section:
0690 Combination Tap Assemblies
Section Subtitle:
Combined bath filler and overflow(s).
WRAS Approval Number:
251002002
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Stainless steel braided EPDM lined flexible hose assembly with a ½” BSP (F) captive nut end connection.
Marking:
C.G.S. S.r.l logo on waste operating member
Installation Requirements:
R001 R576
Expiry date:
31/10/2030
Model:
122YY.XX 132YY.XX YY = Length 122.XX Exact 55 cm 132.XX Exact 55 cm 122-1.XX Max. 70 cm 132-1.XX Max. 70 cm 122-2.XX Max. 80 cm 132-2.XX Max. 80 cm 122-3.XX Max. 90 cm 132-3.XX Max. 90 cm 122-4.XX Max. 105 cm 132-4.XX Max. 105 cm 122-5.XX Max. 115 cm 132-5.XX Max. 115 cm 122-6.XX Max. 125 cm 132-6.XX Max. 125 cm XX = Finish 122YY.01 Standard Chrome 132YY.01 Standard Chrome 122YY.05 PVD Chrome 132YY.05 PVD Chrome 122YY.06 Black Chrome 132YY.06 Black Chrome 122YY.12 Gold 132YY.12 Gold 122YY.15 Rose Gold 132YY.15 Rose Gold 122YY.17 PVD Gold 132YY.17 PVD Gold 122YY.25 Brushed Bronze 132YY.25 Brushed Bronze 122YY.26 Brushed Copper 132YY.26 Brushed Copper 122YY.33 White Matt 132YY.33 White Matt 122YY.35 White 132YY.35 White 122YY.43 Black Matt 132YY.43 Black Matt 122YY.40 Brushed Nickel 132YY.40 Brushed Nickel 122YY.45 Black 132YY.45 Black

Approval Holder:
C.G.S. S.R.L.
Company Name
C.G.S. S.R.L.
Address
Via Torino 9/A Cureggio (NO)
Postcode
28060
Country
Italy
General Email
f.cerutti@cgsmixer.com

View All Listings by this Company
Manufacturer:
C.G.S. S.R.L.
Company Name
C.G.S. S.R.L.
Address
Via Torino 9/A Cureggio (NO)
Postcode
28060
Country
Italy
General Email
f.cerutti@cgsmixer.com

View All Listings by this Company

Print This Approval


#250708301

Section:
2011 Shower Valves
Description:
A Shower valve(s) with thermostatic temperature control, incorporating a manual diverter between outlets.
Wall Mounted Concealed Two-way diverter
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Installation Requirements:
R001 R020
Expiry date:
31/07/2030

Product IdentificationSurface finishInlet DimensionMax Wrk. PressureMax Op. Temp.MarkingMarking LocationAll metals in the water pathway are on the 4msi positive listHeadworkFixing TypeSpout Outlet Includes
GUTH71Brass1/2" NPT (M)6 bar65 °CWaterworksBodyNo1/4 Turn ceramic disk
GUTH61 *Brass1/2" NPT (M)6 bar65 °CWaterworksBodyNo1/4 Turn ceramic disk

Notes & Further Information

Product Identification with an * as suffix = models added 11/082025


Approval Holder:
Waterworks Ltd
Company Name
Waterworks Ltd
Address
60 Backus Ave. Danbury
Postcode
CT06810
Country
United States
Phone
2035466207
General Email
mary.kimlinger@waterworks.com

View All Listings by this Company

Print This Approval


#250904701

Non-verifiable double check valve assembly with DZR brass body, incorporating two spring loaded, resilient trim in-line check valve cartridges. Compression connection to be used with copper pipe BS EN1057 only. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C for 12.10102.035.CP5R-8511, Maximum operating temperature 65°C for 12.10112.035.CP5R-8511.

Section:
0034 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Type ED - Non-verifiable double check valve.
WRAS Approval Number:
250904701
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
35mm compression.
Marking:
V&G, CR, size, flow arrow & WRAS on body, Date of manufacture MM-YY on body. EN1254-2 & size on compression nut
Installation Requirements:
R001
Expiry date:
30/09/2030
Model:
12.10102.035.CP5R-8511 12.10112.035.CP5R-8511

Manufacturer:
Zhejiang Valogin Technology Co. Ltd.
Company Name
Zhejiang Valogin Technology Co. Ltd.
Address
Qinggang Technological Ind. Zone, Yuhuan, Zhejiang
Country
China

View All Listings by this Company

Print This Approval


#250904706

Versol Electrical Water Heater Tank, with a stainless-steel tank body. Max working pressure 10 bar. Max operating temperature 95°C.

Section:
0090 Calorifiers
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½ “ BSP (F).
Marking:
Versol on body. Versol, capacity, pressure and tech info on label.
Installation Requirements:
R001
Expiry date:
30/09/2030
Model:
SO-30 Water Heater Tank– 30 L SO-50 Water Heater Tank – 50 L SO-80 Water Heater Tank - 80 L SO-100 Water Heater Tank - 100 L SO-120 Water Heater Tank - 120 L

Approval Holder:
Versol Ltd Sp Zoo,
Company Name
Versol Ltd Sp Zoo,
Address
Robotnicza 38, 39-100 Ropczyce

View All Listings by this Company

Print This Approval


#250815306

Section:
0440 Headworks
Description:
A Headwork(s) for installation into specifically dimensioned taps or shower valve bodies.
Brass body/bodies
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Installation Requirements:
R001
Expiry date:
31/08/2030

Product IdentificationSurface finishInlet DimensionMax Wrk. PressureMax Op. Temp.MarkingMarking LocationAll metals in the water pathway are on the 4msi positive listHeadworkFixing TypeSpout Outlet Includes
XDSV12BSP 1/2" (M)16 bar85 °CCompany logoBodyNo

Approval Holder:
ZHEJIANG XINDONG SANITARY WARE CO.,LTD.
Company Name
ZHEJIANG XINDONG SANITARY WARE CO.,LTD.
Address
XUANMEN INDUSTRIAL ZONE YUHUAN CHINA
Country
CHINA

View All Listings by this Company
Manufacturers:
Zhejiang Xindong Sanitary Ware Co., Ltd

Print This Approval


#250905301

Section:
0450 Combination Tap Assemblies
Description:
A Range of Single hole tap(s) with a single outlet and a fixed spout.
Deck Mounted. Capable of achieving AUK3 Tap Gap.
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Installation Requirements:
R001 R006
Expiry date:
30/09/2030

Product IdentificationSurface finishInlet DimensionMax Wrk. PressureMax Op. Temp.MarkingMarking LocationAll metals in the water pathway are on the 4msi positive listHeadworkFixing TypeSpout Outlet Includes
TVW103006000XXVarious½” BSP (M)10 bar60 °CVilleroy & BochOn the leverYes1/4 Turn ceramic diskPlastic BacknutsAerator
TVW104002000XXVarious½” BSP (M)10 bar60 °CVilleroy & BochOn the leverYes1/4 Turn ceramic diskPlastic BacknutsAerator

Notes & Further Information

XX at the end indicates the Finish of surfaces that are not in contact with water (61 - Chrome, K5 - Matt black, 76 - Brushed gold, 64 - Brushed nickel) The products were already tested according to the TCS. The report from SKZ is attached.


Approval Holder:
Villeroy & Boch AG
Company Name
Villeroy & Boch AG
Address
Saaruferstraße 1-3 Mettlach
Postcode
66693
Country
Germany
Phone
+49 151 16775778
General Email
Finkler.Marc@villeroy-boch.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 203 of 247

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.