"Yi Sin" Range of press fittings with a stainless steel body and EPDM ‘O’ rings for use with stainless steel 316L pipe manufactured to EN10312. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Allpex range of end feed capillary fittings and brazing fittings for use with copper tube (manufactured to BS EN 1057). EG fittings have gunmetal bodies, ED fittings have DZR brass bodies & EB fittings have brass bodies. For above ground use only. Maximum working pressure: 6mm – 34mm 25Bar, 34mm -54mm 25Bar, 54mm – 108mm 16Bar, 108mm – 159mm 5 Bar. Maximum operating temperature 30°C
Range of dual flush syphonic WC flush valves. Cold water use only.
Range of dual flush syphonic WC flush valves. Cold water use only.
Range of direct fired water heaters with an enamel lining and a titanium anode. Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The products are supplied with isolation valve on both the DHW and CH circuits. The secondary circuit (DHW) incorporates a plastic flow restrictor and stainless-steel strainer. Some models (see model section) are supplied with a filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve. Maximum working pressures: DHW: 10.0 Bar CH: 2.5 Bar Maximum operating temperature: DHW: 65.0°C CH: 85.0°C
Range of wall mounted combination boilers providing domestic hot water (DHW) via a plate heat exchanger and pressurised central heating (CH) system. Incorporating a pressure relief valve set at 3.0 bar and expansion vessel. Supplied with a filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve. Maximum working pressure Primary circuit (CH) 2.5Bar, Secondary circuit (DHW) 10.0 Bar Maximum operating temperature 90.0°C
Range of integrated water circuits incorporating a plate heat exchanger. The units incorporate a flow sensor, pressure relief valve set at 3.0 bar, and a primary circuit circulation pump. Maximum working pressure secondary circuit 10.0 bar. Maximum working pressure primary circuit 2.5 bar. Maximum operating temperature 70°C. Cold supply only.
Range of ¼ turn ceramic disc (brass bodies), non rising spindles (brass bodies) or ceramic cartridge headworks (plastic bodies) insertion into specifically dimensioned tap assemblies. Maximum working pressure 10.0 Bar Maximum operating temperature 85.0°C
Range of in-line and concentric water meters with composite bodies, TPE gasket and NBR ‘O’-ring(s). The products have an integral plastic filter. The inlet of the in-line models includes a non-return valve. Maximum working pressure 16.0 bar. Cold water use only.
Range of water meters with brass bodies, plastic turbines and plastic strainers on inlets. The products have an integral plastic filter. The inlet includes a non-return valve. Maximum working pressure 16.0 Bar Maximum operating temperature 23.0°C
Octave range of water meters with blue epoxy coated cast iron or plastic bodies (see models). Maximum working pressure 16.0 Bar. Maximum operating temperature 50.0°C
‘Helvatron H2O’ range of ultrasonic water meters with brass bodies and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of concealed, wall mounted rough insets, incorporating cross-top and single lever operating members. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C
Spray handset for personal hygiene (brass bodied - various finishes) incorporating a trigger mechanism controlling the flow. The handset also has a locking ring. The inlet incorporates an approved check valve cartridge with an integral plastic flow regulator; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The products are supplied with a shower hose. Model (5840/MBG/W) is supplied with a single lever trim set. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C
Spray handset for personal hygiene (brass bodied - various finishes) incorporating a trigger mechanism controlling the flow. The handset also has a locking ring. The inlet incorporates an approved check valve cartridge with an integral plastic flow regulator; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of shower outlets with plastic bodies (various finishes). Model 100184782 has flow regulator at the inlet and a shower arm. Maximum working pressure: open outlet. Maximum operating temperature: 70°C.
Range of overhead shower outlets with chromium plated brass bodies. For installation with specific rough kit sets, incorporating stainless steel strainers and flow regulators in the inlet. Maximum operating temperature 80.0°C For open outlet use
Range of shower handsets and shower kits. Shower kits 2.1703.391, 2.1703.015 & 2.1703.016 incorporate a shower handset, shower hose and riser rail. Shower handset inlets incorporate a flow regulator. Maximum operating temperature 60°C.
Range of shower outlets with chrome plated brass bodies incorporating a single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Model 28450410 is a wall elbow for use with the shower sets and incorporates a check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Open outlet use only. Maximum operating temperature: 60.0°C
Page 201 of 311
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.