Range of single hole, single outlet (fixed) combination tap assemblies ( brass bodies - various finishes), incorporating either a ceramic cartridge or ceramic disc (see models) headworks with either a single lever or cross top (see models) operating member. The spout outlet incorporates either a plastic aerator, a plastic flow straightener or an open outlet type spout (see models). Some models are supplied with a click type waste and some are supplied with a lever type pop-up waste (see models). Maximum working pressure 5.0 Bar or 10.0 Bar
Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
---|---|---|---|---|---|---|---|---|---|---|---|
193938 X XXX | VARIOUS | ½” BSP | 5.0 bar | 65 °C | PPI | BODY | No | Ceramic cartridge | C-plate | Aerator & Flow Straightener | |
194828 X XXX | VARIOUS | ½” BSP | 10.0 bar | 65 °C | PPI | BODY | No | Ceramic cartridge | C-plate | Aerator & Flow Straightener | |
181028 X XXX | VARIOUS | ½” BSP | 10.0 bar | 65 °C | PPI | BODY | No | Ceramic cartridge | C-plate | Aerator & Flow Straightener |
X XXX Denotes the following: First X: Different handle and the second, third & fourth XXX for different finishes: Handles: A (Lever type) Chrome – No suffix, Brushed brass – BGP, PVD Gold – PVD, Brushed Nickel – BN1, Gun Metal – GMG, Matt Black – MBK, Matt White – MWH, Stainless Steel – SS1, Black Chrome – BCP, Titanium – TIB and Antique Bronze – AB1.
Range of single hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes, see model), incorporating a ceramic cartridge headwork with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a single sequential headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. The product is supplied with DZR brass adaptors for installation on each inlet. The adaptor incorporates a stainless-steel strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of single-hole, single outlet, (fixed) combination tap assemblies (chrome plated brass bodies), incorporating ceramic cartridge headworks with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Range of single hole, single outlet (fixed) combination tap assemblies with either stainless steel (models 49xxS604WF & 49xxP704WF only) or brass (all other models) bodies (various finishes). The products incorporate a ceramic cartridge headwork with either single lever, cylindrical or no supplied operating members (see models). The spout outlets incorporate a plastic aerator and model 58xxL904F is supplied with a lever operated pop up waste. Maximum working pressure 10.0 Bar. Maximum operating temperature 80°C.
Range of single-hole, single outlet, (fixed) combination tap assemblies (brass bodies – various finishes), incorporating non-rising spindle headworks and single lever or dome type operating members. The spout outlet incorporates a plastic aerator. Supplied with a lever type pop up waste – not tested. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with (brass bodies - various finishes), incorporating a ceramic cartridge headwork with single lever operating members. The spout outlet incorporates a plastic aerator. Models 6500H/W & 6504/W are supplied with a click type waste – not verified by test. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Floor standing, single hole, single outlet (swivel) combination tap assembly with brass bodies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member and a manual diverter to a shower outlet. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chrome plated brass bodies), incorporating quarter turn ceramic disc headworks with dome operating members. The spout outlets incorporate plastic aerators or flow straighteners. The product is supplied with metal back nuts. Maximum working pressure – 10.0 Bar Maximum operating temperature - 70 °C
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies (chrome plated brass bodies), incorporating ceramic cartridge headworks with single lever operating members. The spout outlet incorporates plastic aerators. Maximum working pressure: 5.0 Bar. Maximum operating temperature: 70 °C
Range of wall mounted, concealed, two-hole single outlet (fixed) combination tap assemblies, incorporating a ceramic cartridge headwork with single lever operating members. The concealed body is either brass (UBR0257) or nickel plated brass (all other models). The spout and trim set have brass bodies with various finishes, see model. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperatures 65°C.
Range of wall mounted, two hole, single outlet fixed combination tap assemblies, (brass bodies - various finishes). (Series 9097) incorporates ceramic disc diverter valve controlling the flow. Temperature is controlled independently via a thermostatic cartridge Incorporating a manual override button. The inlets incorporate stainless steel strainers and approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. All other models incorporate ceramic cartridge headworks with single lever operating member and ceramic disc diverter valves diverting flow between spout outlet and shower outlets. Maximum working pressure 5.0 Bar Maximum operating temperature 60.0°C
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass body), incorporating ceramic cartridge headwork with single lever operating member. The headwork and the spout are connected by a PEX lined flexible hose. The spout outlets incorporate a plastic aerator, and the products are supplied with metal backnuts. Models supplied with pop-up waste – not tested. Maximum working pressure 10 Bar. Maximum operating temperature 70°C.
Range of two hole, double outlet (swivel) combination tap assemblies (chrome plated brass). (T-695 series) Incorporates quarter turn ceramic disc headworks with single lever operating members. (T-695M series) incorporates non-rising spindle headworks and dome or cross top type operating members (T-695M). The spout outlets incorporate a plastic flow straightener. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of three-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headwork with either single lever, dome, wheel or cross top operating members. The headworks are connected to the spout with stainless steel braided braided PEX lined flexible hose assemblies. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Floor standing spout outlet (chromium plated brass) incorporating a plastic aerator and a concealed brass floor mounting. Maximum operating temperature 60°C.
Range of chemical dosing equipment which incorporate self-closing valves within a plastic body with EPDM o-rings. The outlet of the injector incorporates a connection for injection of chemicals via venturi action. Only suitable for use with chemicals no greater than a FC3, additional backflow protection is required for chemicals greater than FC3. Maximum working pressure 9.0 bar. Maximum operating temperature 70ºC.
Range of cylindrical expansion vessels with epoxy coated or uncoated steel bodies and Butyl membranes. Maximum working pressure 10.0 Bar Maximum operating temperature 99.0°C.
Range of in-line water filters with plastic bodies. Maximum working pressure 8.0 bar. Cold water use only.
Page 195 of 201
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.