Range of spherical valves with various operating members, brass bodies, brass balls, FKM ‘O’-rings or EPDM ‘O’-rings (S84W series only) and PTFE seats. Maximum working pressure 40.0 bar. Maximum operating temperature 85°C.
Range of lever operated spherical valves with nickel plated brass bodies incorporating chromium plated brass balls. For use with copper pipe. Maximum working pressure 25.0 bar. Maximum operating temperature 100°C.
Range of quarter turn, lever handle or butterfly operated spherical valves with nickel plated brass bodies, chrome plated brass balls and PTFE seals. For use with copper pipe BS EN 1057. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of full bore spherical valves with single lever, lockable lever or butterfly operating members, nickel plate brass bodies and chrome plated, brass ball, PTFE seats and NBR O-rings.
Range of resilient seated gate valves with blue epoxy coated ductile iron bodies, and an EPDM wedge, gasket and ‘O’-ring. The FGAXXXNYYRB231 model has a rising spindle, the FGAXXXNYYNB231 model has a non-rising spindle, both have a handwheel operating member. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of gate valves with a non-rising spindle and a handwheel operating member. The 960985, 960986 & 960987 suffix models have a brass body and brass wedge, the 850066, 850070 & 850071 suffix models have a DZR brass body and a brass wedge. For use with copper pipe (manufactured to EN1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of gate valves incorporating blue epoxy coated ductile iron body and EPDM coated wedge. The valves operate via a non-rising spindle headwork with hand wheel operating member. Maximum working pressure 17.24 bar. Maximum operating temperature 85°C.
Range of gate valves with brass bodies, brass wedges and PTFE seals. The valves are operated via a non-rising spindle with a hand wheel operating member. To be used with copper pipe manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of angled, screw-down stop valves, (chrome plated brass bodies) and NBR seals. Compression fitting for use with copper to BS EN 1057. Maximum working pressure 10.0 Bar Maximum operating temperature 85°C.
Protecta-line range of screw down stopcocks with Gunmetal body’s incorporating NBR O-rings. The stopcocks are to be used with Protecta-line PE80 multi-layer pipe manufactured to BS 8558. Maximum working pressure 12.5bar. Cold water use only.
Range of commercial, front loading washing machines with flow controlled by a solenoid valve and discharged via type AB air gap assembly (verified by test, suitable for backflow protection against fluid category 5). The inlets incorporate a stainless-steel strainer. Maximum working pressure 6 Bar Maximum operating temperature 85°C
Range of electrolytic water conditioning units consisting of stainless-steel tube with a copper/zinc alloy sacrificial anode and brass inlet and outlet connections. Compression models are for use with copper pipe (manufactured to BS EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of magnetic, electrolytic or combined magnetic & electrolytic scale inhibitors with nickel plated copper bodies, for use with copper pipe manufactured to BS EN 1057. Maximum working pressure 12.0 bar. Cold water use only.
Range of electro-magnetic water conditioners with chrome plated stainless steel bodies Compression models are for use with pipe manufactured to BS EN 1057. Maximum working pressure 10 bar. Cold water use only.
'CD 101 P6'. Grey coloured (opaque), ceramic disc component manufactured by powder pressing, sintering and grinding. For use with water up to 85°C.
'Art-Coat'. Factory applied, colourless (transparent) PTFE based surface treatment coating. Apply as per manufacturer's instructions 'revision 3' dated 16-03-2020. Cure for 45 minutes@55-60°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
`RVK JDP01`. Factory applied, blue coloured epoxy coating. Apply and cure as per manufacturer's technical information document reference 'RVK-PRD-DI-002, issue #1' dated 2017. For use with water up to 85°C.
'EBONITA AL'. Factory applied, blue coloured hard rubber coating. Apply adhesives and coating in accordance with manufacturer's Technical Data Sheet dated 1st September 2022. Cure for 8 hours@140°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Lak Series 2000 - Fusion Bonded Epoxy’. Factory applied, epoxy powder coatings available in the following colours: Code 25-1113: Description RAL5005 Blue Signal R.C. (dark blue coloured). Code 25-1117: Description RAL5015 Blue Sky R.C. (light blue coloured). Code 29-1116: Description RAL9005 Black Jet R.C. (black coloured). Apply as per manufacturer's technical information 'Rev.2,1 Q1 - 2021'. Cure for 10 minutes@180°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘Series 2000 – Fusion Bonded Epoxy’. Factory applied, epoxy powder coatings available in the following colours: Code 29-0008: Description RAL9005 Black Deep FBE. Code 25-0084: Description RAL5015 Blue Sky. Code 25-1110: Description RAL5005 Blue Signal. Code 23-0004: Description Red Oxide Primer. Code 25-1160: Description SABSF29 NCS Blue Cornf. Apply as per manufacturer's technical information 'Rev.2,1 Q1 - 2021'. Cure for 10 minutes at 180°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Page 180 of 508
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.