Range of shower handsets with chrome plated plastic bodies. The inlets incorporate a plastic flow regulator and strainer. Maximum operating temperature 60°C.
Tempomix 3 794BOX1 concealed, wall mounted shower valve (brass body) for use with Tempomix 3 794218 & Tempomix 3 794219 functional/trim (chromium plated brass) kits. The functional/trim kits incorporate a self-closing spring-loaded headwork with a dome type operating member that controls both flow and temperature. 794219 also incorporates a chrome plated brass shower outlet that has a flow regulator. The inlets to the 794BOX1 incorporate stop valves, plastic filters and approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Overhead shower outlets with brass bodies (various finishes), incorporating EPDM O rings. Maximum working pressure: Open outlet Maximum operating temperature 60.0°C
Range of in-line `Y`-patterned strainers with brass bodies incorporating a stainless steel mesh strainer and a PTFE washer. Maximum working pressure 25.0 Bar. Maximum operating temperature 99.0°C
Range of Y type strainers with blue epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C
Wall mounted bib taps (chromium plated brass) incorporating quarter turn ceramic disc headwork with single lever operating members. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Pillar taps (chromium plated brass) incorporating a quarter turn ceramic disc headwork with a single lever operating member. The spout outlets incorporate a plastic flow straightener. Model are supplied with plastic backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks, available with either cross top (M3101 & M3102) or single lever (M3201 & M3202) operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal back nuts Maximum working pressure 10.0 Bar Maximum operating temperature 85.0°C
Range of stainless steel or nylon braided, PEX lined flexible hose assemblies with various end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
‘S800’ flexible reinforced hose assembly with dual layered (black inner & grey outer) and PVC lining with a plastic strainer. Maximum working pressure 10.0 bar. Hoses manufactured from 2023: Maximum operating temperature: 60°C
Range of PVC or EPDM lined shower hoses with stainless steel outer (chrome or black finish) or PVC reinforced (chrome plated finish) outer layer. Maximum operating temperature 65°C.
Range of PVC lined shower hoses with black inner layer and silver plastic outer layer. Maximum operating temperature 60˚C.
Range of stainless steel or nylon braided, PEX lined flexible hoses with a variety of end connectors. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C
Elisa Range of multi-layer shower hoses with a PVC inner hose, supplied with EPDM ‘O’-rings. Maximum operating temperature 60°C.
Range of stainless steel interlocked (H35 models) or nylon braided (H36 models) flexible hose assemblies. H35 models are available with either a silicone or TPE liner, the H36 models are available with a TPE liner only. Maximum operating temperature 60°C.
Range of stainless steel or nylon braided, PEX or EPDM inner liner flexible hose assemblies available in a range of various end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless steel or nylon braided, thermoplastic silicone rubber (TPSiV) lined flexible hoses with a variety of end connectors. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Centerstore ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.
Range of CENTERSTORE AIR bubble top indirect and direct single coil unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 10.0 bar@90˚C. A safety kit (manifold) consisting of a single check valve assembly, verified by test (suitable for backflow prevention against fluid category 2), strainer, an expansion relief valve set at 8.0 bar and a pressure reducing valve set at 3.0 bar and a tundish is also provided. Alternative inlet control group and temperature and pressure relief valve added March 2023. Maximum working pressure: Secondary circuit: 7.5 bar. Primary circuit: 6.0 bar. Maximum operating temperature 65°C.
Range of indirect unvented indoor heat pump storage cylinders which consist of a heat pump which sits on top of the tank and heats the hot water via refrigeration pipes which then heats the cylinder by being externally mounted around the cylinder. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar @ 90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve pre-set at 3.0 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum working pressure 6.0 Bar (Secondary) Maximum operating temperature 55.0°C
Page 172 of 508
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.