#240902016

Self-closing, wall mounted bib tap (chromium plated brass) with spring loaded headwork and dome type operating members. The spout outlet incorporates a plastic aerator with integral flow regulator or optional flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.

Section:
1820 Taps
Section Subtitle:
Self closing tap(s).
WRAS Approval Number:
240902016
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP M
Marking:
Armitage Shanks on operating member
Installation Requirements:
R001 R040
Expiry date:
30/09/2029
Model:
S7241AA Avon 21
Product Images

Approval Holder:
Armitage Shanks
Company Name
Armitage Shanks
Address
Old Road (Lodge 1), Armitage, Rugeley
Postcode
WS15 4BT
Country
Staffordshire,
Phone
+44 800 866 966 Fax: 01543 491677 Telex: 339781

View All Listings by this Company

Print This Approval


#240902020

Range of TPE shower hoses (various finishes) with EPDM seals. Open outlet use only. Maximum operating temperature 60.0°C

Section:
1860 Tubes
Section Subtitle:
Plastic hoses.
WRAS Approval Number:
240902020
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (F) Captive nut
Marking:
Axor on nut
Installation Requirements:
R001
Expiry date:
30/09/2029
Model:
28 282 xx0 28 284 xx0 28 286 xx0 Where xxx denotes the surface finish (which is a non-water contact part). It will always be 3 digits, which can be any combination of numbers and/or letters, as examples: 000 = chrome optic finish, 800 = PVD stainless steel optic finish.
Product Images

Approval Holder:
Hansgrohe SE
Company Name
Hansgrohe SE
Address
Auestrasse 5 - 9, Schiltach
Postcode
77761
Country
Germany
Phone
+49 170 4471 718
General Email
Ludovic.hauer@hansgrohe.com

View All Listings by this Company
Manufacturer:
Hansgrohe SE
Company Name
Hansgrohe SE
Address
Auestrasse 5 - 9, Schiltach
Postcode
77761
Country
Germany
Phone
+49 170 4471 718
General Email
Ludovic.hauer@hansgrohe.com

View All Listings by this Company

Print This Approval


#240902006

Stainless steel interlocked (chrome plated) silicone lined kitchen tap pull-out hose. Open outlet use only. Maximum operating temperature 85°C.

Section:
1863 Tubes
Section Subtitle:
Elastomeric.
WRAS Approval Number:
240902006
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
M12 x M12.
Marking:
Dornbracht on ferule.
Installation Requirements:
R001
Expiry date:
30/09/2029
Model:
04300212000
Product Images

Approval Holder:
Dornbracht GmbH & Co. KG.
Company Name
Dornbracht GmbH & Co. KG.
Address
Koebbingser Muehle 6 Iserlohn
Postcode
D-58640
Country
Germany
Phone
+49 2371 433 0
General Email
wpape@dornbracht.com

View All Listings by this Company

Print This Approval


#2103041

Ultraflow ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2103041
Note:
Expansion vessels should be installed in the vertical orientation and located so that the length of the connecting pipework is kept to a minimum.
Size:
22mm compression (Inlet Manifold)
Marking:
Ultraflow on front, technical information on adhesive label on body.
Installation Requirements:
R001 R140 R360
Expiry date:
31/03/2026
Proviso:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°c and 45°c.
Model:
UD90 - ULTRAFLOW 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UD120 - ULTRAFLOW 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. UD150 – ULTRAFLOW 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UD170 – ULTRAFLOW 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. UD200 – ULTRAFLOW 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UD250 – ULTRAFLOW 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UD300 – ULTRAFLOW 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UI90-ULTRAFLOW 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UI120 - ULTRAFLOW 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UI150 - ULTRAFLOW 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UI170 - ULTRAFLOW 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UI200 - ULTRAFLOW 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UI250 - ULTRAFLOW 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UI300 - ULTRAFLOW 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UWD170 -ULTRAFLOW 170 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER UWD200 -ULTRAFLOW 200 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER UWD250 -ULTRAFLOW 250 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER UWD300 -ULTRAFLOW 300 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER UWI170 ULTRAFLOW 170 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER UWI200 ULTRAFLOW 200 NDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER UWI250 ULTRAFLOW 250 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER UWI300 ULTRAFLOW 300 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER UDS60-ULTRAFLOW SLIM 60 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. UDS90-ULTRAFLOW SLIM 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UDS120-ULTRAFLOW SLIM 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UDS150D-ULTRAFLOW SLIM 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UDS170D-ULTRAFLOW SLIM 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UDS200D-ULTRAFLOW SLIM 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. UIS60-ULTRAFLOW SLIM 60 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UIS90-ULTRAFLOW SLIM 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UIS120-ULTRAFLOW SLIM 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UIS150-ULTRAFLOW SLIM 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UIS170-ULTRAFLOW SLIM 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UIS200-ULTRAFLOW SLIM 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER

Approval Holder:
L & M (HEATING) SUPPLIES LTD.
Company Name
L & M (HEATING) SUPPLIES LTD.
Address
103 LOCKFIELD AVENUE ENFIELD, ENFIELD, MIDDLESEX
Postcode
EN3 7PY

View All Listings by this Company

Print This Approval


#2201107

Range of Ultraflow Air bubble top indirect and direct single coil unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 10.0 bar@90˚C. A safety kit (manifold) consisting of a single check valve assembly, verified by test (suitable for backflow prevention against fluid category 2), strainer, an expansion relief valve set at 8.0 bar and a pressure reducing valve set at 3.0 bar and a tundish is also provided. Alternative inlet control group and temperature and pressure relief valve added January 2023. Maximum working pressure: Secondary circuit: 7.5 bar. Primary circuit: 6.0 bar.

Non-metallic materials and components comply with BS6920 at 65°C

Section:
1890 Unvented Heating Apparatus
Size:
Secondary circuit: 22mm compression. Primary circuit: 22mm compression. Return circuit: 22mm compression.
Marking:
Ultraflow Air on label on front of body.
Installation Requirements:
R001 R140 R360
Expiry date:
31/01/2027
Model:
UOD120 – ULTRAFLOW AIR 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. UOD150 – ULTRAFLOW AIR 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UOD170 – ULTRAFLOW AIR 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. UOD200 – ULTRAFLOW AIR 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UOD250 – ULTRAFLOWAIR 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UOD300 – ULTRAFLOW AIR 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UOI120 – ULTRAFLOW AIR 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UOI150 – ULTRAFLOW AIR 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UOI170 – ULTRAFLOW AIR 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UOI200 – ULTRAFLOW AIR 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UOI250 – ULTRAFLOW AIR 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UOI300 - ULTRAFLOW AIR 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UODS120-ULTRAFLOW AIR SLIM 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UODS150-ULTRAFLOW AIR SLIM 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UODS170-ULTRAFLOW AIR SLIM 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UODS200-ULTRAFLOW AIR SLIM 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. UOIS120-ULTRAFLOW AIR SLIM 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UOIS150-ULTRAFLOW AIR SLIM 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UOIS170-ULTRAFLOW AIR SLIM 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UOIS200-ULTRAFLOW AIR SLIM 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER

Approval Holder:
L & M (HEATING) SUPPLIES LTD.
Company Name
L & M (HEATING) SUPPLIES LTD.
Address
103 LOCKFIELD AVENUE ENFIELD, ENFIELD, MIDDLESEX
Postcode
EN3 7PY

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1631 of 2344

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.