Existing:
VNx1/xx2 Ixxx3 x4x5x6 Nx7 x8Bx9x10x11Nx12 D,
x1CN/xx2 Ixxx3 x4x5x6 Nx7 x8Bx9x10x11Nx12 D,
VLx1/xx2 Ixxx3 x4x5x6 Nx7 x8Bx9x10x11Nx12 D,
x1CL/xx2 Ixxx3 x4x5x6 Nx7 x8Bx9x10x11Nx12 D,
ESx1/xx2 Ixxx3 x4x5x6 Nx7 x8Bx9x10x11Nx12 D,
x1CS/xx2 Ixxx3 x4x5x6 Nx7 x8Bx9x10x11Nx12 D.
Where:
VN, CN, VL, CL, ES, CS = Series name.
VN/VL/ES series “E-TECH” brand,
CN/CL/CS Series “FPS” brand.
x1 = Nominal Flow:
3, 5, or 9. (9 is not available on ES and CS models)
xx2 = number of impellers, (depending on Nominal Flow and Frequency):
2 to 10 (VN/CN & VL/CL models),
2 to 8 (ES/CS models).
I = Material:
St/Steel 1.4301 (AISI304).
xxx3 = Motor Power (kW x 10):
005, 007, 009, 011…
x4 = Supply (no phase):
T: three phase,
M: single phase.
x5 = Frequency (Hz):
5: 50 Hz,
6: 60 Hz.
x6 = Motor Configuration:
L: Bi-phase, 90° single-phase,
D: Three-phase, triangle),
Y: Three-phase, star.
N = Mechanical seal elastomer:
N: NBR.
x7 = Mechanical Seal surface:
1: Graphite/Silicon Carbide,
2: Silicon Carbide/Silicon Carbide.
x8 = Float Switch:
0: without.
B = Cable type:
B: Blue.
x9 = Cable size:
A: 4G1,
B: 4G1.5,
C: 3G1,
D: 3G1.5.
x10 = Cable length:
O: 20m (VN/CN and ES/CS models),
E: 5m (VL/CS models).
x11 = Control Panel (not in contact with liquid):
0: without),
1: connected (VN/CN models only).
N = Nude terminal (not in contact with liquid).
x12 = Option (only on VN/CN models) - Discharge head (”):
Empty: 1¼” Nickel plated brass,
I: 1¼” Inox,
J: 2” Inox.
D = Drinking water approved.
--------------------------------------------
From November 2025 VNE and VLE models added + new naming structure as follows:
VN or VNEx1/xx2 x3xxx4 x5x6x7 x8 xxx9Bx10x11xxx12,
VL or VLE x1/xx2 x3xxx4 x5x6x7 x8 xxx9Bx10x11xxx12.
Where:
VN, VNE, VL, VLE = Series name.
VN/VNE/VL/VLE series “Franklin Electric” brand.
x1 = Nominal Flow:
3, 5, or 9 (VN and VL series).
3, 6, or 10 (VNE and VLE series).
xx2 = number of impellers, (depending on Nominal Flow and Frequency):
2 to 10.
x3 = Suction:
S: Screened (submersible application),
I: Inline (for surface dry application).
xxx4 = Motor Power (kW x 10):
005, 007, 009, 011…
x5 = Supply:
T: three phase,
M: single phase.
x6 = Frequency (Hz):
5: 50 Hz,
6: 60 Hz.
x7 = Voltage:
1: 115V,
2: 230V,
3: 280V,
4: 460V.
x8 = Float Switch:
0: without.
xxx9 - Mechanical seal:
QQP: Silicon Carbide/Silicon Carbide/NBR.
B = Cable type:
B: Blue.
x10 = Cable length:
05: 5m (VL/VNE/VLE models),
20: 20m (VN/VNE models).
x11 = Plug:
(“Blank”) Without plug.
x12 = Discharge head dimension:
R14: Rp 1¼” thread (Inox),
R20: Rp 2” thread (Inox) (VN/VNE models only).
--------------------------------------------
ESx1/xx2 Ixxx3 x4x5x6 Nx7 x8Bx9x10x11Nx12 D,
x1CS/xx2 Ixxx3 x4x5x6 Nx7 x8Bx9x10x11Nx12 D.
Where:
ES, CS = Series name.
ES series “E-TECH” brand,
CS Series “FPS” brand.
x1 = Nominal Flow:
3 or 5.
xx2 = number of impellers, (depending on Nominal Flow and Frequency):
2 to 8.
I = Material:
St/Steel 1.4301 (AISI304).
xxx3 = Motor Power (kW x 10):
005, 007, 009, 011…
x4 = Supply:
T: three phase,
M: single phase.
x5 = Frequency (Hz):
5: 50 Hz,
6: 60 Hz.
x6 = Motor Configuration:
L: Bi-phase, 90° single-phase,
D: Three-phase, triangle,
Y: Three-phase, star.
N = Mechanical seal elastomer:
N: NBR.
x7 = Mechanical Seal surface:
1: Graphite/Silicon Carbide,
2: Silicon Carbide/Silicon Carbide.
x8 = Float Switch:
0: without.
B = Cable type:
B: Blue.
x9 = Cable size:
A: 4G1,
B: 4G1.5,
C: 3G1,
D: 3G1.5.
x10 = Cable length:
O: 20m.
x11 = Control Panel (not in contact with liquid):
0: without.
N = Nude terminal (not in contact with liquid).
D = Drinking water approved.