Range of wall mounted brass bodied spout outlets (various finishes, see model) incorporating a plastic aerator. Maximum working pressure 10.0 Bar
Non-metallic materials and components comply with BS6920 at 60°C
Range of longitudinal (EFW) welded stainless steel (Grade 304/304L & 316/316L) pipes. Maximum working pressures: 1¼” sch 10: below ground = 55.0 bar. Above ground = 74.0 bar. 1½” sch 10: below ground = 48.0 bar. Above ground = 64.0 bar. 2” sch 10: below ground = 38.5 bar. Above ground = 51.0 bar. 2½” sch 10: below ground = 34.5 bar. Above ground = 46.0 bar. 3” sch 10: below ground = 28.0 bar. Above ground = 38.0 bar. 4” sch 10: below ground = 22.0 bar. Above ground = 29.0 bar. 5” sch 10: below ground = 19.5 bar. Above ground = 26.0 bar. 6” sch 10: below ground = 16.0 bar. Above ground = 22.0 bar. 8” sch 10: below ground = 14.0 bar. Above ground = 18.0 bar. ½” sch 40 & ¾” sch 40: below ground = 60.0 bar. Above ground = 80.0 bar. 1” sch 40: below ground = 30.0 bar. Above ground = 40.0 bar. 1¼” sch 40 & 1½” sch 40: below ground = 60.0 bar. Above ground = 80.0 bar. 2” sch 40: below ground = 54.5 bar. Above ground = 72.0 bar. 2½” sch 40: below ground = 60.0 bar. Above ground = 80.0 bar. 3” sch 40: below ground = 52.0 bar. Above ground = 69.0 bar. 4” sch 40: below ground = 44 bar. Above ground = 58.0 bar 5” sch 40: below ground = 38.5 bar. Above ground = 51.0 bar. 6” sch 40: below ground = 35.0 bar. Above ground = 46.0 bar. 8” sch 40: below ground = 31.0 bar. Above ground = 41.0 bar. Maximum operating temperature 100°C.
‘Super Speedfit’ range of plastic pushfit fittings (black, light grey, dark grey, white, natural, and red) for use with John Guest LLDPE tubing (blue, black, natural, green, orange, red, white and yellow). Operating parameters: 5/32”, ¼”, 5/16”, 4mm & 6mm = 16.0 bar cold water & 8.0 bar at 65°C. 3/8” = 10.0 bar cold water & 7.0 bar at 65°C. ½” = 10.0 bar cold water & 6.0 bar at 65°C. 8mm, 12mm & 15mm = 10.0bar cold water & 6.0 ba at 65°C. 10mm = 10.0bar cold water & 7.0 bar at 65°C.
Range of ‘Superseal’ and ‘Speedfit’ push-fit fittings with acetal body’s (black or light grey) and NBR ‘O’ rings. For use with John Guest LLDPE tubing (Speedfit port only) and 316 stainless steel tubing manufactured to EN10088 (Superseal push-fit port only). Pipe inserts must be used for the LLDPE tube sizes 3/8” and ½”. Maximum working pressure: See models below. For cold water use only.
Electric, instantaneous, vented, mains water heaters with plastic housings and silicon gaskets. Incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow prevention. Maximum working pressure 1.5 bar.
Non-metallic materials and components comply with BS6920 at 98°C
Range of air- or water-cooled commercial ice making machines with flow controlled via solenoid valve. Maximum working pressure 5 Bar
Non-metallic materials and components comply with BS6920 at 35°C
Range of commercial air or liquid cooled ice making machines with water controlled via solenoid valve. Maximum working pressure 5.5 Bar COLD WATER USE
Range of water meters with (blue epoxy coated) brass bodies and plastic working chamber. The inlets incorporate a plastic filter. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 50°C
‘H5000’ range of helical rotor, bulk water meters with blue epoxy coated cast iron bodies and nitrile `O` rings. Maximum working pressure 16.0 bar. Cold water use only.
Range of water meters with blue epoxy coated ductile iron bodies, plastic measurement chambers and vanes and NBR ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of water meters with brass bodies, plastic turbines and EPDM washers. Inlets incorporate a plastic filter. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 50°C
‘V210’ range of volumetric water meters with brass bodies and NBR ‘O’-rings. Available with a mechanical or electronic register. Maximum working pressure 16.0 bar. Cold water use only.
‘V200’ range of rotating piston (semi positive) volumetric in-line water meters with brass bodies, EPDM ‘O’-rings and seal (DN40 model only), NBR ‘O’-rings (all other models) and seal (DN15 36RPL model only). Available with a mechanical or electronic register. Maximum working pressure 16.0 bar. Cold water use only.
‘V110’ range in-line volumetric water meters with black plastic bodies. Maximum working pressure 16.0 bar. Cold water use only.
Range of quick release couplers with a brass body and EPDM O-rings. Maximum working pressure 12.0 bar.
Non-metallic materials and components comply with BS6920 at 99°C
Range of in-line plastic flow restrictors housed within black or grey glass fibre reinforced nylon bodies. Maximum working pressure 16.0
Non-metallic materials and components comply with BS6920 at 85°C
Range of water pressure booster sets with a cold water storage cistern and booster pump. All models incorporate a non-return valve, not suitable for backflow protection. These models have an AG air gap suitable for fluid category 3 protection. Maximum working pressure 6.0 bar. Cold water use only.
Range of water pressure booster sets with a cold water storage cistern and booster pump. All models incorporate a non-return valve, not suitable for backflow protection. These models have an AB air gap suitable for fluid category 5 protection. Maximum working pressure 6.0 bar. Cold water use only.
Range of vertical multistage pumps with stainless-steel bodies, stainless-steel impellers, shaft and outer sleeve. Maximum working pressures: T (oval flange): 16.0 bar. V (Victaullic & grooved), C (clamp flanges) & F (round flange) versions: 26.0 bar. Maximum operating temperature 100°C.
Range of horizontal self-priming multistage pumps with stainless steel bodies, stainless steel impellers, shaft and outer sleeve. Maximum working pressure 10.0 Bar Maximum operating temperatures: FGH Three phase models 85°C, FGH Single phase models 55.0°C
Page 153 of 522
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.