Range of three hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes - see model), incorporating quarter turn ceramic disc headworks with various operating members (see models). The products are supplied with two stainless steel braided EPDM lined flexible hose assemblies with ½” captive nut end connections for installation between the side valves and the spout. The spout outlet incorporates a plastic aerator. Maximum working pressure 3.0 bar. Maximum operating temperature 60°C.
Three hole, single outlet (fixed) combination tap assembly with a brass body (various finishes - see model), incorporating quarter turn ceramic disc headworks with single lever operating members. The products are supplied with two stainless steel braided EPDM lined flexible hose assemblies with ½” captive nut end connections for installation between the side valves and the spout. The spout outlet incorporates a combined plastic aerator. Maximum working pressure 3.0 bar. Maximum operating temperature 60°C.
Spout outlet with a brass body (chrome plated). The spout outlet incorporates a combined plastic flow regulator and aerator. Maximum operating temperature 60°C.
Range of wall mounted spout outlets with brass bodies (chrome plated). Product is supplied with various operating members and pop up click waste. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Wall mounted waterfall, bath spout (chromium plated brass), incorporating a flow regulator on the inlet and stainless-steel strainer at the spout outlet. Maximum operating temperature 80°C. Open outlet use only
Range of wall mounted spout outlets, (brass bodies with various finishes) incorporating a plastic aerator. Maximum operating temperature: 60°C
Range of wall mounted spout outlets incorporating brass bodies (various finishes) and plastic flow straighteners. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C
Range of stainless-steel axial expansion bellows with threaded end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Chlorine Dioxide dosing system consisting of various PVC pipes and fittings, a water meter and a spherical valve. The inlet incorporates a double check valve assembly (verified by test as suitable for backflow protection against Fluid Category 3). Maximum working pressure 10.0 bar. Cold water use only.
‘CD3 Series’ chlorine dioxide dosing system incorporating a single check valve positioned at the point of injection. Maximum working pressure 6.0 bar. Cold water use only.
Range of expansion vessels with EPDM membrane and stainless steel flange connections. Models VB8, VB12, VB18 & VB24 have a maximum working pressure of 16.0 bar. All other models have a maximum working pressure of 10.0 bar. Maximum operating temperature 100°C.
Range of expansion vessels with stainless steel and epoxy coated carbon steel bodies incorporating a butyl rubber membrane. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
Range of filling loop assemblies, comprising of a stainless steel braided EPDM lined hose, isolation valve with a DZR brass body and ball and an isolation valve with a DZR brass body and ball incorporating two check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3). The F1400120012211 model has an isolation valve incorporating two check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3) at each end of the filling loop. All items except the hoses are nickel plated. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of carbon block water filters and housings. Maximum working pressure 10.5 bar. Cold water use only.
Range of water filter housings with plastic heads and bodies (various colours - see model), incorporating NBR ‘O’-rings (158087/088/207/208/218/219/261 models only) or with EPDM ‘O’-rings (all other models). Big Blue for Cartridges - Maximum working pressure 6.9 bar (10” filter housings) and 6.2 bar (20” filter housings). Maximum working temp 38°C. All other models - Maximum working pressure 8.62 bar. Maximum working temp 52°C.
Carbon block filter cartridge with plastic body. The cartridge may be installed with a manifold (filter head) for use with PE tubing manufactured to BS 1972. Maximum working pressure 8.6 bar. Cold water use only
‘Multi Press Leak M.P.L’. range of fittings (pressing profile TH and U) for use with Alpex Duo XS multi-layered pipe. For above ground use only. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
‘Comisa’ range of brass bodied press-fit and threaded fittings for use with `Comisa’ (PE-RT/AL/PE-LMD) multi-layer pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Dual flush WC outlet valve with an ABS body, incorporating a silicone seal & internal overflow. The valve is operated via a push button assembly for either full or reduced flush. Cold water use only.
Range of urinal flushing mechanisms with a solenoid valve controlling the flow. The valves are controlled via an infra-red sensor. The inlet incorporates a stainless steel strainer and flow regulator. Maximum working pressure 10.0 bar. Cold water use only.
Page 127 of 561
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.