#240902039

Range of VEGAPULS radar sensors for level measurement with plastic bodies. Cold water use only. Open outlet use only.

Section:
1530 Miscellaneous Fittings
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
See model key
Marking:
VEGA logo date of manufacturer (YYYY), serial number and other technical data on body
Installation Requirements:
R001
Expiry date:
30/09/2029
Model:
PSC21.ab-c-d-N-f-g-h-I VEGAPULS C 21 PSC22.ab-c-d- N -f-g-h-I VEGAPULS C 22 PSC23.ab-c-d- N -f-g-h-I VEGAPULS C 23 PS21.ab-c-d- N -f-g-h-I VEGAPULS 21 PS31.ab-c-d- N -f-g-h-I VEGAPULS 31 KEY FOR VEGAPULS C 21 ab = explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, RCM, EAC) VH ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 (Class II, III Division 1, 2) VB ATEX/UKEX/IEC; Gas, Encapsulation, Zone 1, 2 + Dust, Protection by enclosure, Zone 20, 21/22, 21, 22 SH EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 + Dust, intrinsic safety Zone 20, 20/21, 21, 22 SB EAC/SEPRO; Gas, encapsulation, Zone 1, 2 + Dust, encapsulation Zone 21, 22 TH CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, Intrinsic safety, Zone 20, 20/21, 21, 22 (not CCOE) TB CCOE, NEPSI, KTL, TIIS; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 (not CCOE) WH INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 WB INMETRO/IA; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 FB c-FM-us/c-CSA-us; Gas, encapsulation, Zone 1, 2 (Class I Division 2) + Dust, protection by enclosure, Zone 20, 20/21, 21, 22 (Class II, III Division 1) FR c-FM-us/c-CSA-us; Gas, non-incendive, Class I Division 2 + Dust-ignitionproof, Class II, III Division 1 c = Approved as overfill protection, which can be displayed as; X without W with (WHG, VLAREM) d = Ship approval, which can be displayed as; X without S with (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff / Pharmaceutical certificate, which can be displayed as; X without N with (NSF/ANSI/CAN 61) P with (NIH) F with (FDA, EG1935/2004) f = Thread process side / Cable side, which can be displayed as; G Thread G1½ / G1 N Thread 1½NPT / 1NPT R Thread R1½ / R1 g = Cable material / Length, which can be displayed as; A PUR / 5m (approx. 16ft) B PUR / 10m (approx. 32ft) H PUR / 15m (appr. 48ft) J PUR / 20m (appr. 64ft) C PUR / 25m (approx. 82ft) D PUR / individually selectable (acc. to CE, RCM, EAC) D PUR / individually selectable (acc. to c-FM-us, c-CSA-us) h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART W Four-wire Modbus S Three-wire SDI12 i = Sensor setting via smartphone and VEGA Tools app, which can be displayed as; X without B with KEY FOR VEGAPULS C 22 ab = Explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, c-FM-us, c-CSA-us, RCM, EAC) VH ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 (Class II, III Division 1, 2) VB ATEX/UKEX/IEC; Gas, Encapsulation, Zone 1, 2 + Dust, Protection by enclosure, Zone 20, 21/22, 21, 22 SH EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 + Dust, intrinsic safety Zone 20, 20/21, 21, 22 SB EAC/SEPRO; Gas, encapsulation, Zone 1, 2 + Dust, encapsulation Zone 21, 22 TH CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, Intrinsic safety, Zone 20, 20/21, 21, 22 (not CCOE) TB CCOE, NEPSI, KTL, TIIS; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 (not CCOE) WH INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 WB INMETRO/IA; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 FB c-FM-us/c-CSA-us; Gas, encapsulation, Zone 1, 2 (Class I Division 2) + Dust, protection by enclosure, Zone 20, 20/21, 21, 22 (Class II, III Division 1) FR c-FM-us/c-CSA-us; Gas, non-incendive, Class I Division 2 + Dust-ignition proof, Class II, III Division 1 c = Approved as overfill protection, which can be displayed as; X without W with (WHG, VLAREM) d = Ship approval, which can be displayed as; X without S with (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff / Pharmaceutical certificate, which can be displayed as: X without N with (NSF/ANSI/CAN 61) P with (NIH) F with (FDA, EG1935/2004) f = Process fitting, which can be displayed as; G Thread G1½ N Thread 1½NPT R Thread R1½ g = Cable material / length, which can be displayed as; A PUR / 5m (approx. 16ft) B PUR / 10m (approx. 32ft) H PUR / 15m (appr. 48ft) J PUR / 20m (appr. 64ft) C PUR / 25m (approx. 82ft) D PUR / individually selectable (acc. to CE, RCM, EAC) D PUR / individually selectable (acc. to c-FM-us, c-CSA-us) h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART W Four-wire Modbus S Three-wire SDI12 i = Sensor setting via smartphone and VEGA Tools app, which can be displayed as; X without B with KEY FOR VEGAPULS C 23 ab = explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, RCM, EAC) VH ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 (Class II, III Division 1, 2) VB ATEX/UKEX/IEC; Gas, Encapsulation, Zone 1, 2 + Dust, Protection by enclosure, Zone 20, 21/22, 21, 22 SH EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 + Dust, intrinsic safety Zone 20, 20/21, 21, 22 SB EAC/SEPRO; Gas, encapsulation, Zone 1, 2 + Dust, encapsulation Zone 21, 22 TH CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, Intrinsic safety, Zone 20, 20/21, 21, 22 (not CCOE) TB CCOE, NEPSI, KTL, TIIS; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 (not CCOE) WH INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 WB INMETRO/IA; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 FB c-FM-us/c-CSA-us; Gas, encapsulation, Zone 1, 2 (Class I Division 2) + Dust, protection by enclosure, Zone 20, 20/21, 21, 22 (Class II, III Division 1) FR c-FM-us/c-CSA-us; Gas, non-incendive, Class I Division 2 + Dust-ignitionproof, Class II, III Division 1 c = Approved as overfill protection, which can be displayed as; X without W with (WHG, VLAREM) d = Ship approval, which can be displayed as; X without S with (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff / Pharmaceutical certificate, which can be displayed as; X without N with (NSF/ANSI/CAN 61) P with (NIH) F with (FDA, EG1935/2004) f = Thread process side / Cable side, which can be displayed as; F Thread G1 M Thread 1NPT Q Thread R1 g = Cable material / length, which can be displayed as; A PUR / 5m (approx. 16ft) B PUR / 10m (approx. 32ft) H PUR / 15m (appr. 48ft) J PUR / 20m (appr. 64ft) C PUR / 25m (approx. 82ft) D PUR / individually selectable (acc. to CE, RCM, EAC) D PUR / individually selectable (acc. to c-FM-us, c-CSA-us) h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART W Four-wire Modbus S Three-wire SDI12 i = Sensor setting via smartphone and VEGA Tools app, which can be displayed as; X without B with KEY FOR VEGAPULS 21 / 31 ab = explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, c-FM-us, c-CSA-us, RCM, EAC) AX without, for Ex-free area (CE, UKCA, RCM) VC ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) SC EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 TC CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 WC INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 c = Approved as overfill protection, which can be displayed as; X Without W With (WHG, VLAREM) d = Ship approval, which can be displayed as; X Without S With (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff/Pharmaceutical certificate, which can be displayed as X Without N With (NSF/ANSI/CAN 61) P With (NIH) F With (FDA, EG1935/2004) f = Process fitting, which can be displayed as; G Thread G1½ N Thread 1½NPT R Thread R1½ g = Cable entry / connection, which can be displayed as; M M20x1.5 / Cable gland PA black (ø5-9mm), standard h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART i = Sensor setting via smartphone and VEGA Tools app X Without B With
Product Images

Approval Holder:
VEGA Grieshaber KG
Company Name
VEGA Grieshaber KG
Address
Am Hohenstein 113 Schiltach
Postcode
77761
Country
Germany
General Email
info.de@vega.com

View All Listings by this Company
Manufacturer:
VEGA Grieshaber KG
Company Name
VEGA Grieshaber KG
Address
Am Hohenstein 113 Schiltach
Postcode
77761
Country
Germany
General Email
info.de@vega.com

View All Listings by this Company

Print This Approval


#240702045

Range of positive displacement diaphragm pumps with plastic bodies, EPDM ‘O’-rings and TPE diaphragm. The product incorporates an integral bypass relief valve. For use with John Guest LLDPE Pipe. Maximum working pressure 12.0 Bar. Maximum operating temperature 40.0°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
240702045
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
5/16" Push fit, 3/8" Push fit.
Marking:
Aquatec name and logo, model number, serial number and date of manufacture (DD/MM/YY) on adhesive label on body.
Installation Requirements:
R001
Expiry date:
31/07/2029
Model:
535X-2XXW-XXXX, 537X-2XXW-XXXX. Model Code Denotes: 1st & 2nd designators = 53 - Series Demand Delivery Pumps. 3rd designator is port size for pumphead housing, where ‘5’ = 3/8” or ‘7’ = 5/16” . 4th designator is cam angle for flow performance variation only. X can be 0 to 9. 5th designator ‘2’ indicates that pump has bypass relief control. 6th designator is for pressure setting of relief valve. X can be A to Z depending on pressure setting. 7th designator ‘X’ is a code for the specific materials in this model, e.g. Nylon pumphead housing. 8th designator ‘W’ = WRAS Compliant 9th - 12th designators XXXX can be any alphanumeric characters to denote electrical motor and motor mounting base plate combination.
Product Images

Approval Holder:
Aquatec International Inc
Company Name
Aquatec International Inc
Address
17422 Pullman Street, Irvine, CA 92614, U.S.A.

View All Listings by this Company
Manufacturer:
Aquatec International Inc
Company Name
Aquatec International Inc
Address
17422 Pullman Street, Irvine, CA 92614, U.S.A.

View All Listings by this Company

Print This Approval


#2205915

Range of shower outlets with matte black finishes, consisting of a shower hose, handset, riser rail and a brass wall mounted inlet. Maximum operating temperature 60°C.

Section:
1650 Shower Outlets
Section Subtitle:
Shower head(s) and/or shower handset(s).
WRAS Approval Number:
2205915
Note:
Open outlet use only.
Size:
1/2" BSP (M)
Marking:
Bristan on shower handset.
Installation Requirements:
R040
Expiry date:
31/05/2027
Model:
RP3 SQR KIT01 C

Approval Holder:
Bristan Group Ltd.
Company Name
Bristan Group Ltd.
Address
Birch Coppice Business Park Dorden Tamworth
Postcode
B78 1SG
Country
Staffs
Phone
01827 254144
General Email
hmistry@bristan.com

View All Listings by this Company

Print This Approval


#2302901

Range of chrome plated shower kits consisting of shower hoses with EPDM washers incorporating stainless steel strainers at the captive nut, handsets and riser rail assemblies. Maximum operating temperature 60°C.

Section:
1650 Shower Outlets
Section Subtitle:
Shower head(s) and/or shower handset(s).
WRAS Approval Number:
2302901
Note:
Open outlet use only.
Size:
1/2" BSP (F) captive nut end connections.
Marking:
Bristan on handset.
Installation Requirements:
R001 R040
Expiry date:
29/02/2028
Model:
RP3 CAS KIT02 C

Approval Holder:
Bristan Group Ltd.
Company Name
Bristan Group Ltd.
Address
Birch Coppice Business Park Dorden Tamworth
Postcode
B78 1SG
Country
Staffs
Phone
01827 254144
General Email
hmistry@bristan.com

View All Listings by this Company

Print This Approval


#2309935

Range of shower kits, comprising of an overhead shower incorporating a stainless-steel strainer washer and riser rail assembly.

Non-metallic materials and components comply with BS6920 at 85°C

Section:
1650 Shower Outlets
Section Subtitle:
Shower head(s) and/or shower handset(s).
WRAS Approval Number:
2309935
Note:
STC16 STA16
Size:
15mm compression.
Marking:
HERITAGE on shower head.
Installation Requirements:
R001 R040
Expiry date:
30/09/2028
Model:
RP3 STC16

Approval Holder:
Bristan Group Ltd.
Company Name
Bristan Group Ltd.
Address
Birch Coppice Business Park Dorden Tamworth
Postcode
B78 1SG
Country
Staffs
Phone
01827 254144
General Email
hmistry@bristan.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1239 of 1717

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.