Two hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (swivel) combination tap assemblies (brass body - various finishes), incorporating quarter turn ceramic disc headworks with either single lever or wheel operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Two-hole, single outlet fixed combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a lockable self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener The product is supplied with a shower hose and handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Two-hole, single outlet fixed combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a lockable self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener The product is supplied with a shower hose and handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Two-hole, single outlet fixed combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a lockable self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener The product is supplied with a shower hose and handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes - see model), incorporating quarter turn ceramic disc headworks with single lever operating members and a locakble self-cancelling diverter to shower outlet. The spout outlets incorporate a plastic aerator. The product is supplied with a shower hose and handset and metal backnuts Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Range of wall mounted three hole, single outlet (fixed) combination tap assemblies with brass bodies (in various finishes). Incorporating quarter turn ceramic disc headworks and various operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes - see model), incorporating quarter turn ceramic disc headworks with various operating members (see model). The products are supplied with stainless steel braided EDPM lined flexible hose assemblies incorporating ¾” captive nut end connections for installation between the headworks and the spout. The spout outlet incorporates either a plastic flow straightener or plastic aerator (see model). The invincible range is supplied with a plastic back nut, all other models are supplied with metal back nuts. Maximum working pressure 3.0 bar. Maximum working temperature 60°C.
Three hole, single outlet (fixed) combination tap assembly with a brass body (various finishes - see model), incorporating quarter turn ceramic disc headworks with dome type operating members. The products are supplied with stainless steel braided EDPM lined flexible hose assemblies incorporating ¾” captive nut end connections for installation between the headworks and the spout. The spout outlet incorporates a plastic aerator. The product is supplied with metal back nuts. Maximum working pressure 3.0 bar. Maximum working temperature 60°C.
Range of three-hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever (20815882 model) or cross top (20815892 model) operating members. The product is supplied with stainless steel braided PEX lined flexible hose assemblies for installation between the side valves and the spout. The spout outlets incorporate a plastic aerator. The side valves are supplied with plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Functional trim set (chrome plated), comprising of a ceramic cartridge headwork with a single lever operating member and a spout outlet. The spout incorporates a plastic flow regulator on the inlet and a plastic aerator on the outlet. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Functional trim set (chrome plated), comprising two quarter turn ceramic disc headworks with either single lever (models ending in 882) or cross top (models ending in 892) operating members and a spout outlet. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Bath spout outlet with a brass body (various finishes) and a plastic aerator. Maximum operating temperature 60°C.
Range of deck mounted spout outlets (chrome plated brass). The spout incorporates a plastic flow regulator on the inlet and a plastic aerator on the outlet. Maximum working temperature 60°C.
Range of wall mounted basin spouts (chromium plated brass). The spout incorporates a plastic flow regulator on the inlet and a plastic aerator on the outlet. Maximum operating temperature 60°C.
Range of expansion vessels incorporating composite plastic bodies and butyl diaphragms. Maximum working pressure 8.6 bar. Cold water use only.
Range of SUS316L & SUS304 stainless steel press fittings for use with stainless steel pipe manufactured to EN 10312. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of press fit fittings incorporating copper (GP5 models) or bronze (GP4 models) bodies and EPDM `O`-rings, for use with copper tube to EN 1057. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of copper end feed fittings for use with copper tube. For above and below ground use. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.
Range of dual flushing WC outletvalves with plastic bodies and silicone gasket. Cold water use only.
Page 107 of 554
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.