Section Code 1800 : Pillar, metal.
Back To Directory SectionsRange of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks, with single lever operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal back nuts Maximum working pressure 10.0 Bar
Non-metallic materials and components comply with BS6920 at 85°C
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal back nuts Maximum working pressure 10.0 Bar Maximum operating temperature 85.0°C
Range of pillar taps (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener (Models 152101, 152102, 179401 &179402) or a plastic aerator (Models 130401 & 130402). The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C for all models except 179401 & 179402 which are 85°C
Pillar tap (chromium plated brass) incorporating a quarter turn ceramic disc headwork with single lever type headwork. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks, available with either cross top (400145 & 400146) or single lever (310802 & 310803) operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal back nuts Maximum working pressure 10.0 Bar Maximum operating temperature 85.0°C
Range of pillar taps (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener (Models A05017, A05018, A05490 & A05491) or a plastic aerator (Models A05029 & A05030). The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C for all models except A05490 & A05491 which are 85°C
A wall mounted, self-closing pillar tap (chromium plated brass), incorporating a spring-loaded headwork with a dome type operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 Bar.
Non-metallic materials and components comply with BS6920 at 60°C
Basin pillar taps (chromium plated brass) with ¼ turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Bath pillar taps (chromium plated brass) with ¼ turn ceramic disc turn headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Pillar taps with chromium plated - brass bodies incorporating a quarter turn ceramic disc headwork, with single lever type operating members. The spout outlet incorporates a flow straightener. The product is supplied with plastic backnuts. Maximum working pressure 10 bar.
Non-metallic materials and components comply with BS6920 at 45°C
Range of pillar taps (chrome plated brass bodies) incorporating quarter turn ceramic disc headworks with cross top operating members. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of pillar taps (chrome plated brass bodies) incorporating quarter turn ceramic disc headworks with cross top operating members. The product is supplied with metal back nuts. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of pillar tap (chrome plated brass), incorporating quarter ceramic disc headworks with single lever or dome type operating members. The spout outlets incorporate plastic aerators. Products are supplied with metal backnuts. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of basin pillar taps (brass bodies - various finishes), incorporating self-closing headwork and a plastic aerator in the outlet. Maximum working pressure 10.0 Bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of pillar taps ( brass bodies – various finishes), incorporating quarter turn ceramic disc headworks with various type operating members. The spout outlets incorporate plastic flow straighteners (except models 173601 & 173602 that have open outlets) and the products are supplied with metal back nuts. Maximum working pressure 10 bar. Maximum operating temperature 85°C.
Range of pillar taps ( brass bodies – various finishes), incorporating quarter turn ceramic disc headworks with various type operating members. The spout are open outlets and the products are supplied with metal back nuts. Maximum working pressure 10 bar. Maximum operating temperature 85°C.
Range of pillar tap (chromium plated brass bodies), incorporating quarter ceramic disc headworks with single lever, cross-top or dome type operating members. Model (F6128) incorporates an open spout outlet, all other spout outlets incorporate plastic aerators. Products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Non-metallic materials and components comply with BS6920 at 65°C
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc (VL101) or non-rising spindle headworks (all other models) with various operating members and metal backnuts. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 6.0 Bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc (VL103) or non-rising spindle headworks (all other models) with various operating members and metal backn uts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 6.0 Bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of pillar taps with brass bodies, (various finishes - see model), incorporating quarter turn ceramic disc headworks with cross top or single lever operating members (see model). The spout outlet of the F5117** model incorporates a plastic aerator. The spout outlet of the F5197**, F6007**, F6008** & F6117C** models incorporates a plastic flow straightener. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Page 10 of 12
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.