Combination Tap Assemblies

Section Code 0470 : Single hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.

Back To Directory Sections

#2001014

Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 Bar. Maximum operating temperature 55°C.

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2001014
Expiry date:
31/01/2025
Size:
Stainless steel braided EPDM lined flexible hose assemblies with ½" BSP captive nut end connections.
Marking:
AV on back of operating member
Installation Requirements:
R001 R006 R010
Model:
Fizz: ACT3007.
Factor:
ABODE - a division of NORCROS GROUP (Holdings) Limited
Company Name
ABODE - a division of NORCROS GROUP (Holdings) Limited
Phone
01226 283434
General Email
info@abodedesigns.co.uk

View All Listings by this Company

Print This Approval


#2003815

Range of single hole single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating a ceramic cartridge headwork with a single lever operating members. The outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2003815
Expiry date:
31/03/2025
Size:
Stainless steel braided EPDM lined flexible hose assemblies incorporating ½” captive nut end connections
Marking:
NABIS ON OPERATING MEMBER
Installation Requirements:
R001 R006 R010
Model:
B08919 NABIS PASILLA SINGLE LEVER MONO KITCHEN COMBINATION TAP ASSEMBLIES
Factor:
WOLSELEY
Company Name
WOLSELEY
Address
KINGMAKER COURT WARWICK TECHNOLOGY PARK WARWICK
Postcode
CV34 6DY

View All Listings by this Company

Print This Approval


#2004019

Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass) incorporating a ceramic disc headwork with dome type operating member. The spout outlets incorporate a plastic aerator. Model 33500665 is supplied with a pop-up waste. Maximum working pressure 10.0 bar Maximum operating temperature 60°C.

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2004019
Expiry date:
30/04/2025
Note:
No testing performed on pop-up waste.
Size:
Stainless steel braided PE-X lined flexible hose assemblies incorporating ⅜" captive nut end connections.
Marking:
Dornbracht on body.
Installation Requirements:
R001 R006 R009 R010
Model:
33500665, 33505665, 33510665, 33525665 & 33534665
Manufacturer:
Aloys F Dornbracht GmbH & Co KG
Company Name
Aloys F Dornbracht GmbH & Co KG
Address
Koebbingser Muehle 6 D-58640 Iserlohn Germany
Phone
+49 2371 433 0

View All Listings by this Company

Print This Approval


#2004046

Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating non-rising spindle headworks with dome type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2004046
Expiry date:
30/04/2025
Size:
15mm copper inlet tails.
Marking:
Blanco on rear of body.
Installation Requirements:
R001 R006 R010
Model:
BM5006 - Blanco Caro
Factor:
Blanco Limited
Company Name
Blanco Limited
Address
1 Victor Way, Colney Street, St Albans
Postcode
AL2 2FL

View All Listings by this Company

Print This Approval


#1906398

Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator and pull down spray. The inlet hoses incorporate a combined washer and stainless steel strainer. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1906398
Expiry date:
30/06/2024
Size:
Stainless steel braided PEX lined flexible hose assemblies incorporating 1/2” captive nut end connections
Marking:
Cooke & Lewis on tap body
Installation Requirements:
R001 R006 R009 R010
Model:
3663602792123 COMBINATION TAP ASSEMBLIES
Factor:
Kingfisher International Products Ltd.
Company Name
Kingfisher International Products Ltd.
Address
3 PaddingtonSquare, London
Postcode
W2 6PX

View All Listings by this Company

Print This Approval


#1910358

Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (with various finishes) having ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 8 bar. Maximum operating temperature 60°C

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1910358
Expiry date:
31/10/2024
Marking:
Clearwater on main body
Installation Requirements:
R001 R006 R010
Model:
ZO2AB, ZO2BV, ZO2RC, ZO3AB, ZO3BV, ZO3RC, ZO4AB, ZO4BV & ZO4RC Where: AB=Laskine RC=Wire drawing copper BV=ORB black
Factor:
Clearwater Products
Company Name
Clearwater Products
Address
Unit 5603 Shannon Place, Tewkesbury Business Park, Tewkesbury
Postcode
GL20 8SL
Country
Gloucestershire
Phone
01684 299555

View All Listings by this Company

Print This Approval


#2004318

Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass or brushed steel finish) incorporating ¼ turn ceramic disc headworks with single lever or cube type operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2004318
Expiry date:
30/04/2025
Size:
Stainless steel braided EPDM lined flexible hose assemblies incorporating ½” captive nut end connections.
Marking:
1810 logo on body
Installation Requirements:
R001 R006 R010
Model:
CUR/01/CH, CUR/02/BS, PEN/01/CH, PEN/02/BS, RUS/01/CH, RUS/02/BS, VER/01/CH & VER/02/BS.
Factor:
The 1810 Company limited
Company Name
The 1810 Company limited
Address
Units 14-16, Bromfield Industrial Estate, Queens Lane Mold
Postcode
CH7 1JR
Phone
0044 7772144600

View All Listings by this Company

Print This Approval


#2004326

Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headworks with single lever operating member. The spout outlet incorporates a plastic aerator. The inlets incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2004326
Expiry date:
30/04/2025
Size:
Stainless steel braided PEX lined flexible hose assemblies incorporating ½” captive nut end connections.
Marking:
SMR Logo on rear of operating member.
Installation Requirements:
R001 R006 R009 R010
Model:
HILTON
Manufacturer:
SAN MARCO RUBINETTERIA S.r.l.
Company Name
SAN MARCO RUBINETTERIA S.r.l.
Address
Via Carducci 10 13867 Pray (BI)
Country
Italy

View All Listings by this Company

Print This Approval


#2004335

Range of single hole, single outlet (swivel) combination tap assemblies with a brass bodes with (various finishes) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2004335
Expiry date:
30/04/2025
Size:
Stainless steel braided EPDM lined flexible hose assemblies incorporating ½” captive nut end connections.
Marking:
1810 on operating member.
Installation Requirements:
R001 R006 R010
Model:
CAS/01/CH, CAS/02/BS, COU/01/CH, COU/02/BS, SEN/01/CH & SEN/02/BS. Models added June 2022; CAS/04/COP, CAS/05/GM, CAS/06/GB, CAS/07/MB CAS/08/BGB, COU/01/CH/PQ, COU/04/COP/PQ, COU/06/GB/PQ, COU/04/COP, COU/05/GM, COU/06/GB, COU/07/MB, COU/08/BGB, CAS/01/CH/PQ, CAS/04/COP/PQ CAS/06/GB/PQ
Factor:
The 1810 Company limited
Company Name
The 1810 Company limited
Address
Units 14-16, Bromfield Industrial Estate, Queens Lane Mold
Postcode
CH7 1JR
Phone
0044 7772144600

View All Listings by this Company

Print This Approval


#2004320

Single hole, single outlet (swivel) combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener . Maximum working pressure 10.0 bar. Maximum operating temperature 60°C

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2004320
Expiry date:
30/04/2025
Size:
Stainless steel braided EPDM lined flexible hose assemblies incorporating ½” captive nut end connections
Marking:
Carlota logo on body
Installation Requirements:
R001 R006 R010
Model:
5002-CR
Manufacturer:
Zhejiang Carlota Sanitary Ware Manufactory Co Ltd
Company Name
Zhejiang Carlota Sanitary Ware Manufactory Co Ltd
Address
No. 10 JINBO ROAD, BINGGANG INDUSTRIAL AREA SHAMEN TOWN, YUHUAN, ZHEJIANG
Country
Zhejiang Province

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 10 of 52

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.