#2304375

Range of brass stopcocks. Compression connections, to be used with copper pipe EN1057 only. Maximum working pressure 16.0 bar.

Non-metallic materials and components comply with BS6920 at 85°C

Section:
2310 Valves
Section Subtitle:
Stop, metal, screw down.
WRAS Approval Number:
2304375
Size:
16.20142.812.CP5R-8510 - 15MM X 25MM BRASS, 16.20142.851.CP5R-8510 - 20MM X 25MM BRASS, 16.20142.831.CP5R-8510 - 22MM X 25MM BRASS, 16.20102.840.CP5R-8510 - 25MM X 25MM BRASS, 16.20142.812.CP5R-8511 - 15MM X 25MM DZR, 16.20142.851.CP5R-8511 - 20MM X 25MM DZR, 16.20142.831.CP5R-8511 - 22MM X 25MM DZR, 16.20102.840.CP5R-8511 - 25MM X 25MM DZR.
Marking:
PFP, size, EN1213, flow arrow, date of manufacture: MM-YY, EN1254-2, size stamped on body and nut.
Installation Requirements:
R001 R120
Expiry date:
30/04/2028
Model:
10145508 - 15MM X 25MM BRASS, 10145495 - 22MM X 25MM BRASS, 10145534 - 25MM X 25MM BRASS,

Approval Holder:
Primaflow F & P
Company Name
Primaflow F & P
Address
Votec House, Hambridge Lane, Newbury
Postcode
RG14 5TN
Country
United Kingdom

View All Listings by this Company

Print This Approval


#241204702

‘Satefy group’ with a brass inlet and a DZR brass body which incorporates a lever operated spherical valve, followed by an approved check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) and a plastic bodied pressure relief valve (set at 6.0 bar). The product incorporates a test point. The compression connections are for use copper pipe (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
2345 Valves
Section Subtitle:
Special combination assemblies.
WRAS Approval Number:
241204702
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
15mm compression
Marking:
Caleffi logo, DN15, CR mark and flow arrow cast on body. Date of manufacture WW/YY printed on body. Caleffi and Caleffi logo, flow arrow, CE marking on pressure relief valve body. 6 bar, size, EN1491 and other technical information on pressure relief valve operating gear
Installation Requirements:
R001 R008 R120
Expiry date:
31/12/2029
Model:
528716

Approval Holder:
Caleffi S.p.A
Company Name
Caleffi S.p.A
Address
Strada Regionale 229 n. 25 Fontaneto d'Agogna (NO)
Postcode
28010
Country
Italy
Phone
+39 0322 8491
General Email
gary.perry@caleffi.com

View All Listings by this Company
Manufacturer:
Caleffi S.p.A
Company Name
Caleffi S.p.A
Address
Strada Regionale 229 n. 25 Fontaneto d'Agogna (NO)
Postcode
28010
Country
Italy
Phone
+39 0322 8491
General Email
gary.perry@caleffi.com

View All Listings by this Company

Print This Approval


#240502712

Range of UV disinfection units with stainless steel bodies. Maximum working pressure 10.3 bar. Maximum operating temperature 60°C.

Section:
2411 Disinfection Equipment
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Please refer to model.
Marking:
Luminor Rainier, model, WRAS and serial number on adhesive label on body
Installation Requirements:
R001 R150 R170
Expiry date:
31/05/2029
Model:
Single Lamp UV Disinfection Units: LRx-35X Rainier - 1½” NPT (M). LRx-55X Rainier - 2” NPT (M). LRx-85X Rainier - 2” NPT (M). Double Lamp UV Disinfection Units: LRx-110X Rainier - 2½” NPT (M). LRx-140X Rainier - 3” NPT (M). LRx-175X Rainier - 4” NPT (M). X denotes a UV sensor or a glow plug and is replaced with: 5= Glow Plug & 6 = UV Sensor. X denotes the type of power cord and is replaced with: 1 = NEMA 5/15. 2 = CEE 7/7. 3 = BS1363. 4 = AS/NZ 3112. 5 = NEMA 6/15. Additional Suffixes can be used for different lamps or sensor calibrations: HW, TOC or 50.
Product Images

Approval Holder:
Luminor Environmental Inc.
Company Name
Luminor Environmental Inc.
Address
80 Southgate Drive, Unit 4, Guelph, ON Guelph
Postcode
N1G 4P5
Country
Canada,

View All Listings by this Company

Print This Approval


#240555036

'Edelpoxy FN TM 142'. Factory coloured, red coloured epoxy resin coating consisting of a base and hardener. Mix base and hardener in a 3:1 volume ratio and apply as per manufacturer's IFU 'PCC/ PC 142', dated '10.07.2018'. Cure for 7 days@30°C. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.

Section:
5030 Coatings, Paints & Linings
Section Subtitle:
Factory applied pipe & fittings coatings.
WRAS Approval Number:
240555036
Expiry date:
31/05/2029

Approval Holder:
PC Chanda & Co. PVT Ltd.
Company Name
PC Chanda & Co. PVT Ltd.
Address
Ravi Auto House, 103 Park Street, 6th Floor, Kolkata 700016
Country
India

View All Listings by this Company

Print This Approval


#240555058

'LMI.Hygienic HI-Build Epoxy'. Factory applied, two- component, blue coloured epoxy coating. Mix base and hardener in a weight ratio of 100:15 and apply as per manufacturer's instructions 'LMIEP1403032', dated '22/06/2024'. Cure for 2 hours@20°C. For use with water up to 23°C. This material is only approved for the mixing & curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.

Section:
5030 Coatings, Paints & Linings
Section Subtitle:
Factory applied pipe & fittings coatings.
WRAS Approval Number:
240555058
Expiry date:
31/05/2029

Approval Holder:
L.M.I. Ductile Iron Pipes & Fittings
Company Name
L.M.I. Ductile Iron Pipes & Fittings
Address
Alnasb, Bousher, Muscat Governorate

View All Listings by this Company

Print This Approval


#240955008

'ELECTROLINE ES 1212'. Factory applied, white coloured, two-component, solvent -free epoxy coating. Mix base and hardener in a 2:1 volume ratio and apply as per manufacturer's TDS 'ECL/ TDS / ES1212', issue date '2-Feb-14', version '0'. Cure for 7 days@30°C. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.

Section:
5030 Coatings, Paints & Linings
Section Subtitle:
Factory applied pipe & fittings coatings.
WRAS Approval Number:
240955008
Expiry date:
30/09/2029

Approval Holder:
Electrosteel Castings Ltd.
Company Name
Electrosteel Castings Ltd.
Address
30 B.T. Road, PO Sukchar, District 24 Parganas (N) West Bengal, Kolkata - 700115
Country
743179

View All Listings by this Company

Print This Approval


#2307543

'Sikagard® 1816 (formerly known MasterProtect® 1816)'. Site applied, grey coloured (once applied), two-component Epoxy polysulfide coating. Mix parts A & B in a 78:22 weight ratio and apply coat 1 as per manufacturer’s general method statement ‘MS - AD - Sikagard®-1816-01/2024’ and PDS '020303000000002044 Version 01.01', dated April 2024. Cure coat 1 for 9 hours@25°C. Mix parts A & B in a 78:22 weight ratio and apply coat 2 as per manufacturer’s general method statement ‘MS - AD - Sikagard®-1816-01/2024’ and PDS '020303000000002044 Version 01.01', dated April 2024. Cure coat 2 for 14 days@25°C. For use with water up to 23°C. This material is only approved for the mixing & curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.

Section:
5042 Coatings, Paints & Linings
Section Subtitle:
Site applied pipe and fittings coatings. Compliance with BS6920 relates to the conditions of cure specified in the listing. If the cure conditions are varied from those described below then compliance with BS6920 cannot be assummed without further testing. Where catalysts are required, only tested catalysts in the recommended concentrations should be used. Manufacturer's advice must be sought if any non standard mixing or curing conditions are being considered.
WRAS Approval Number:
2307543
Expiry date:
31/07/2028

Approval Holder:
SIKA UAE LLC/Sika MB Construction Chemicals L.L.C
Company Name
SIKA UAE LLC/Sika MB Construction Chemicals L.L.C
Address
Head Office: P.O. Box 37127, Dubai Investment Park, Phase 1 Expo Road, Dubai
Country
United Arab Emirates

View All Listings by this Company

Print This Approval


#240655011

'ULTRADUR® B4300 G6 FC AQUA WHITE 25262 & ULTRADUR® B4300 G6 FC AQUA BLACK 15142'. White coloured & black coloured, injection moulded PBT materials. For use with water up to 85°C.

Section:
5205 Polybutylene Terephthalate
Expiry date:
30/06/2029

Approval Holder:
BASF SE
Company Name
BASF SE
Address
Carl-Bosch-Str. 38, 67056 Ludwigshafen
Country
Germany

View All Listings by this Company

Print This Approval


#240755040

'Amodel DW-1140 BK 938 & Amodel DW-1150 BK 938'. Black coloured, injection moulded PPA materials. For use with water up to 85°C.

Section:
5257 Polyphthalamides
Expiry date:
31/07/2029

Approval Holder:
Solvay Specialty Polymers USA, LLC
Company Name
Solvay Specialty Polymers USA, LLC
Address
4500 McGinnis Ferry Road Alpharetta GA 30005-3914
Country
USA
Phone
+1 770 772 8200
General Email
SpecialtyPolymers.Americas@solvay.com

View All Listings by this Company

Print This Approval


#2010584

'662016, 662014, 662062 & 662061'. White coloured, PTFE tape manufactured by calendering. For use with water up to 85°C.

Section:
5294 Polytetrafluoroethylene (PTFE)
Section Subtitle:
Components.
WRAS Approval Number:
2010584
Expiry date:
31/10/2025

Approval Holder:
Arctic Hayes Ltd.
Company Name
Arctic Hayes Ltd.
Address
9 Millshaw Park Avenue, Leeds
Postcode
LS11 0LR

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 90 of 125

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.