‘AQI380PRO’. Site applied, two-part (resin & hardener is automatically mixed in a 10:1 volume ratio through dispensing nozzle) anchor resins. Apply and cure as per ’Load time’ cures set out in Table B4 of European Technical Assessment ETA 19/0127’, dated ‘28/02/2019’. For use with water up to 65°C. If the cure conditions are varied from those specified in ’Load time’ cures set out in set out in Table B4 of European Technical Assessment ‘ETA 19/0127’ then the materials are not covered by the scope of the approval. For use only as a resin anchor having been tested at a reduced surface area to volume ratio of 1,000mm² per 1 litre of water.
Range of injection moulded, VMQ rubber gaskets, seals, & `O` rings manufactured from the below compounds. The components are available in blue, green, grey, opaque (beige coloured), red, transparent & yellow. The numbers in the name of the compound indicates the shore hardness between 40 & 80. Tested in-radii sizes: Gaskets: 0.2mm - 5.0mm. Seals & `O` rings: 0.5mm - 5.0mm. S50B04E, S60B00E, S70B06E, S70B07E, S70V02E, S50V01E, S60O02E, S70O05E, S50O03E, S50O05E, S60O01E, S70O03E, S40A01E, S60A00E, S70A02E, S40R03E, S45R01E, S50R10E, S50R01E, S60R05E, S65R04E, S70R04E, S80R01E, S40R02E, S50R06E, S60R07E, S70R19E, S70R24E, S50T05E, S50T00E, S55T00E, S60T00E, S60T00T, S70T04E, S70T00E, S75T00E, S80T00E, & S70G01E. For use with water up to 85°C.
Range of deck mounted, single hole, single outlet (fixed) electronically controlled tap assemblies (chrome plated stainless steel bodies). The flow is controlled by a solenoid valve that is activated via an infrared sensor, and the spout outlets incorporate plastic aerators. Maximum working pressure 8.0 Bar Maximum operating temperature 65.0°C
Range of single hole, single outlet (fixed) combination tap assemblies (chrome plated brass). Flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlets incorporate plastic aerators. Maximum working pressure:8.0 Bar Maximum operating temperature:65 °C
Single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass), flow is controlled by a solenoid valve, activated via an infra-red sensor. The product is supplied with a combined TPE washer and stainless-steel strainer to be installed on the inlet to the solenoid. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 8.0 bar. Maximum operating temperature 65°C.
W/C suite with pan (polyester) and a concealed flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a single flush drop valve for full flush volumes of up to 6 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 Bar. Cold water use only.
Range of deck mounted, single hole, single outlet (fixed) electronically controlled tap assemblies (chrome plated stainless steel or brass bodies, see models). The flow is controlled by a solenoid valve that is activated via an infrared sensor. Temperature is controlled independently via a single lever operating member. The spout outlets incorporate plastic aerators. Supplied with hoses that incorporate stainless steel strainers and an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 Bar Maximum operating temperature 65.0°C
Range of single hole, single outlet (fixed) combination tap assemblies (chrome plated brass bodies). Flow is controlled by solenoid valves activated via an infra-red sensor and the temperature is controlled independently via single lever. The spout outlets incorporate plastic aerators. Maximum working pressure 8 Bar. Maximum operating temperature 65°C.
Page 88 of 88
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.