Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The products are supplied with isolation valve on both the DHW and CH circuits. The secondary circuit (DHW) incorporates a plastic flow restrictor and stainless-steel strainer. Some models (see model section) are supplied with a filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve. Maximum working pressures: DHW: 10.0 Bar CH: 2.5 Bar Maximum operating temperature: DHW: 65.0°C CH: 85.0°C
Range of wall mounted gas fired condensing instantaneous water heaters. Maximum working pressure 10.0bar. Maximum operating temperature 85°C.
Range of horizontal or vertical multi-stage pumps with a stainless-steel body (HM models) or cast iron body with blue coloured cationic resin coating (VM models), incorporating either plastic or stainless-steel impellers (see model), stainless steel sleeve, EPDM gaskets and seals. Maximum working pressure 10.0 bar / 16.0 bar (see models). Cold water use only.
Range of single or twin booster pumps with stainless steel bodies and stainless-steel impellers. Maximum working pressure 8.0 Bar Maximum operating temperature 90.0°C
Range of single or twin shower pumps with brass bodies, brass impeller supplied with flexible connection hoses that incorporate servicing valves. Maximum Working pressure 6 Bar Maximum operating temperature 65°C
Range of overhead shower outlets with (brass bodies – various finishes) incorporating stainless-steel filter washers at the inlet. Maximum operating temperature 85°C.
shower handset with various finishes. Model HS149 incorporates a stainless steel strainer washer at the inlet. Maximum operating temperature 65°C.
Range of overhead shower outlets (chromium plated ABS plastic bodies). Incorporating a combined EPDM washer and stainless-steel strainer on the inlet (all other models). Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower handsets and overhead showers with (plastic or chrome plated plastic bodies). Open Outlet use only Maximum operating temperature 75.0°C
Range of wall mounted hose union taps (brass body or DZR brass body - see model) incorporating a non-rising spindle headwork with a ‘T’-type operating member. The MBHU04DCV model incorporate two approved single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 14.0 Bar. Maximum operating temperature 85°C.
Page 87 of 125
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.