Range of wall mounted, concealed thermostatic shower valves (brass bodies – various finishes) incorporating a 2 way or 3 way diverter controlling the flow to multiple shower outlets using a dome type operating member. Temperature is controlled independently via a thermostatic cartridge incorporating a manual override button with a dome type operating member. The inlets incorporate approved single check valve cartridges however, the complete assembly has not been fully tested to demonstrate that it provides backflow protection. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of T-type blending valve with brass bodies and thermostatic cartridges. Compression models are for use with copper pipe manufactured to EN1057. Maximum working pressure 25.0 Bar. Maximum operating temperature 75°C.
Range of lugged or wafer butterfly valves with either lever or hand wheel operation and a blue epoxy coated ductile iron body. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of butterfly valves with blue epoxy coated ductile iron bodies and discs, and EPDM seals with a wheel type operating member. Maximum working pressure 16.0 Bar Maximum operating temperature 85.0°C
Non-metallic materials and components comply with BS6920 at 85°C
Range of lug, wafer or flanged (see models) butterfly valves with blue epoxy coated ductile iron bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of butterfly valves with an epoxy coated ductile iron body, stainless steel disc and single lever or handwheel operating members. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of concealed, 2-way manual diverter valves incorporating a brass body. To be installed with 59556 000070 IXMO installation unit. Maximum working pressure 10.0 Bar. Maximum operating temperature 70°C.
Range of in-line, manually adjustable pressure reducing valves with nickel plated DZR brass body. Maximum inlet supply pressure 25 bar. Maximum operating temperature 80°C
Range of pressure reducing valves with DZR brass or bronze bodies and manually adjustable outlet pressure range between 2.5bar to 6.0bar Maximum working pressure: 25.0 bar Maximum operating temperature 80°C.
Range of pressure reducing valves with DZR brass or bronze bodies and manually adjustable outlet pressure range between 2.5bar to 6.0bar. Maximum working pressure: 25.0 bar. Maximum operating temperature 80°C.
Page 846 of 1180
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.