Directory Search Results

Print List

#240402076

Range of single hole, single outlet electronically controlled tap assemblies (chromium plated brass). Flow is controlled using a solenoid valve and actuated via the infrared sensor. The spouts incorporate a plastic aerator. Maximum working pressure 8.0 Bar. Maximum operating temperature 65.0°C

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Tap(s) with a non-touch methods of flow control and a single inlet.
WRAS Approval Number:
240402076
Size:
Stainless steel braided, PEX lined flexible hose assemblies with 1/2" BSP captive nut end connections.
Marking:
TSL on top of tap
Installation Requirements:
R001 R006 R009
Expiry date:
30/04/2029
Model:
L962

Approval Holder:
The Splash Lab UK
Company Name
The Splash Lab UK
Address
Unit 34 Meadow Industrial Estate Stockport
Postcode
SK1 2BU
Country
United Kingdom

View All Listings by this Company

Print This Approval


#240402077

Deck mounted single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass). The flow is controlled by a solenoid valve actuated via an infra-red sensor. Temperature is manually blended using a single lever operating member. The spout outlets incorporate plastic aerators. The inlets incorporate approved check valve cartridges, however, the complete assembly has not been fully tested to demonstrate that it provides backflow protection and stainless-steel strainers. Maximum operating pressure 8.0 bar. Maximum operating temperature 65°C.

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Tap(s) with a non-touch methods of flow control and a single inlet.
WRAS Approval Number:
240402077
Size:
Stainless steel braided, PEX lined flexible hoses incorporating 3/8" captive nut end connections.
Marking:
TSL on top of tap
Installation Requirements:
R001 R006 R009 R010
Expiry date:
30/04/2029
Model:
L994

Approval Holder:
The Splash Lab UK
Company Name
The Splash Lab UK
Address
Unit 34 Meadow Industrial Estate Stockport
Postcode
SK1 2BU
Country
United Kingdom

View All Listings by this Company

Print This Approval


#240702013

Range of wall mounted, single hole, single outlet (fixed) electronically controlled tap assemblies (stainless steel bodies). Flow is controlled by a solenoid valve activated by via an infra-red sensor. The spout outlet incorporates a plastic aerator. Maximum working pressure - 8 Bar. Maximum operating temperature - 65 °C.

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Tap(s) with a non-touch methods of flow control and a single inlet.
WRAS Approval Number:
240702013
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
10mm spigot connection
Marking:
Stern logo on tap body
Installation Requirements:
R001 R040
Expiry date:
31/07/2029
Model:
360100 – Cubica B 360200 – Cubica E 360110 – Cubica DP B 360210 – Cubica DP E
Product Images

Approval Holder:
Y. Stern Engineering (1989) Ltd
Company Name
Y. Stern Engineering (1989) Ltd
Address
15 Gan Rave Blvd. Yavne
Postcode
8122217
Country
Israel
Phone
+972 8 9326007
General Email
leah@sternfaucets.com

View All Listings by this Company

Print This Approval


#240702043

Range of wall mounted, two-hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass). The flow is controlled by a solenoid valve activated via infra-red sensor. Temperature is controlled independently via a thermostatic cartridge with a dome operating member which incorporates a manual override button. The spout outlets incorporate plastic aerators, and both inlets incorporate an approved single check valve cartridge (however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection) and stainless-steel strainers. Maximum working pressure 10.0 Bar. Maximum operating temperature 60.0°C.

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Tap(s) with a non-touch methods of flow control and a single inlet.
WRAS Approval Number:
240702043
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
3/4" BSP (M) x 1/2" BSP (M) offset unions.
Marking:
Aquis on tap body.
Installation Requirements:
R001 R010 R040 R570
Expiry date:
31/07/2029
Model:
110.305.11 - W35, 110.306.11 - W35, 110.307.11 - W45, 110.308.11 - W45.
Product Images

Approval Holder:
Aquis Systems AG
Company Name
Aquis Systems AG
Address
Balgacherstrasse 17 9445 Rebstein Switzerland

View All Listings by this Company
Manufacturer:
Aquis Systems AG
Company Name
Aquis Systems AG
Address
Balgacherstrasse 17 9445 Rebstein Switzerland

View All Listings by this Company

Print This Approval


#240704722

Side entry BS1212-4 (2016) compact type float operated valves for use with WC flushing cisterns. The inlet incorporates a strainer. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2075 Float Operated Inlet Valve
Section Subtitle:
Can be used to achieve a recognised air gap arrangement, providing it meets the appropriate backflow requirements. Suitable for use in a WC suite, provided it forms an arrangement which meets the requirements of Type AUK1 air gap and an appropriate WC performance specification.
WRAS Approval Number:
240704722
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
BSP1/2” (M) Plastic, BSP1/2” (M) Brass, BSP3/8” (M) Brass
Marking:
R&T, model & BS1212-4 on body
Installation Requirements:
R001 R550 R560
Expiry date:
31/07/2029
Model:
A1423
Product Images

Approval Holder:
Xiamen R&T Plumbing Technology Co.,Ltd
Company Name
Xiamen R&T Plumbing Technology Co.,Ltd
Address
No.18, Houxiang Road Haicang District Xiamen
Postcode
361022
Country
China
Phone
86-0592-3959422
General Email
rt025@rtplumbing.com

View All Listings by this Company
Manufacturer:
Xiamen R&T Plumbing Technology Co.,Ltd
Company Name
Xiamen R&T Plumbing Technology Co.,Ltd
Address
No.18, Houxiang Road Haicang District Xiamen
Postcode
361022
Country
China
Phone
86-0592-3959422
General Email
rt025@rtplumbing.com

View All Listings by this Company

Print This Approval


#240602715

Range of wall hung concealed WC flushing cisterns with a BS 1212-4 float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a push button assembly. Maximum working pressure - 10 Bar. Cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
240602715
Size:
½” BSP (M)
Marking:
WRAS & Flomasta on cover, 6 litre line inside cistern.
Installation Requirements:
R001 R280 R556 R581
Expiry date:
30/06/2029
Model:
C10100857 C10100856

Approval Holder:
Kingfisher International Products B.V
Company Name
Kingfisher International Products B.V
Address
Rapenburgerstraat 175E, 1011 VM Amsterdam
Country
Netherlands

View All Listings by this Company

Print This Approval


#240602716

Range of wall hung concealed WC flushing cisterns with a BS 1212-4 float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a push button assembly. Maximum working pressure - 10 Bar. Cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
240602716
Size:
½” BSP (M)
Marking:
Flomasta & WRAS on cover, 6 litre line inside cistern.
Installation Requirements:
R001 R280 R556 R581
Expiry date:
30/06/2029
Model:
C10100857 C10100856

Approval Holder:
Kingfisher PLC
Company Name
Kingfisher PLC
Address
1 Paddington Square, London
Postcode
W2 1GG
Phone
07721 260713
General Email
eric.capotummino@kingfisher.com

View All Listings by this Company

Print This Approval


#240704728

Range of non-verifiable double check valve assemblies, consisting of two spring loaded resilient trim in-line check valve cartridges housed in DZR brass bodies with a drain port located between the cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C

Section:
0034 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Type ED - Non-verifiable double check valve.
WRAS Approval Number:
240704728
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
see model
Marking:
IDC etched on body. Size, flow arrow mould on body.
Installation Requirements:
R001
Expiry date:
31/07/2029
Model:
1CVB006 15mm compression, 1CVB008 22mm compression 1CVB010 28mm compression
Product Images

Manufacturer:
IDC Plumbing & Heating Technology (Beijing) Co., Ltd.
Company Name
IDC Plumbing & Heating Technology (Beijing) Co., Ltd.
Address
3rd Floor, Unit 2, Building 2, Section A Zhaowei Science & Technology Park No. 14, Jiuxianqiao Road Chaoyang District Beijing
Postcode
100015
Country
China
Phone
008610 51659550 ext 312

View All Listings by this Company

Print This Approval


#240704715

Sekisui F range of un-insulated GRP sectional cisterns. The larger cisterns have stainless steel internal bracing and UPVC pole supports. Insulated cisterns were added to the approval in March 2025. All cisterns are for cold water use only.

Section:
0135 Cisterns
Section Subtitle:
Cold-water storage with cover or roof - plastic, sectional. Cisterns in this section are not suitable for water for domestic purposes unless they are so modified and installed as to comply in all respects with Schedule 2. Paragraph 16(4), of the Water Supply (Water Fittings) Regulations 1999.
WRAS Approval Number:
240704715
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
1000 Litres to 3,600,000 Litres
Marking:
Sekisui, model and product information on label.
Installation Requirements:
R001 R270 R280 R350
Expiry date:
31/07/2029
Model:
Sekisui F range: FS (1m high). FH, FHX (1.5m high), FW, FWX, FJX (2m high). FT, FTX (2.5m high). FZ, FZX (3m high). FK, FKX (3.5m high). FQ, FQX - (4m high).
Product Images

Approval Holder:
Sekisui Aqua Systems Co., Ltd.
Company Name
Sekisui Aqua Systems Co., Ltd.
Address
21st Floor, Tower West, Umeda Sky Building, 1-30 1-chome, Oyodonaka, Kita-ku, Osaka
Country
Japan

View All Listings by this Company
Manufacturer:
Sekisui Aqua Systems Co., Ltd.
Company Name
Sekisui Aqua Systems Co., Ltd.
Address
21st Floor, Tower West, Umeda Sky Building, 1-30 1-chome, Oyodonaka, Kita-ku, Osaka
Country
Japan

View All Listings by this Company

Print This Approval


#240704050

AXOR UNO Range of single-hole, single outlet, (fixed) over the rim bidet combination tap assemblies, (brass bodies – various finishes). Incorporating ceramic cartridge headworks with single lever or dome type operating members. The spout outlets incorporate plastic aerators. The products are supplied with lever operated pop-up waste (not verified by test). Maximum operating pressure 10 bar. Maximum operating temperature 60°C

Section:
0400 Combination Tap Assemblies - Bidet
Section Subtitle:
Single hole bidet tap(s) with a single outlet fixed spout with swivel nozzle.
WRAS Approval Number:
240704050
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Stainless steel braided PEX lined flexible hose assemblies incorporating 3/8” BSP captive nut end connections.
Marking:
AXOR on operating member
Installation Requirements:
R001 R006 R009 R010
Expiry date:
31/07/2029
Model:
38 211 xx0 45 200 xx0
Product Images

Approval Holder:
Hansgrohe SE
Company Name
Hansgrohe SE
Address
Auestrasse 5 - 9, Schiltach
Postcode
77761
Country
Germany
Phone
+49 170 4471 718
General Email
Ludovic.hauer@hansgrohe.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 786 of 1152

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.