Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies (various finishes - see model), incorporating quarter turn ceramic disc headworks and either single lever or dome type operating members (see model). The spout inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Three hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating quarter turn ceramic disc headworks with single lever operating members. Spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies (brass bodies with various finishes). Incorporating quarter turn ceramic disc and various operating members. The spout outlet incorporates a plastic aerator (except Broadway and Niagara spout options). The product is supplied with nylon braided EPDM lined flexible hose assemblies incorporating ½” captive nut end connections on both ends or at one end and M10 at the other. The hoses are intended to connect between the side body headworks and the spout junction. The spout junction of the Malmaison and Niagara spout options incorporates a plastic flow regulator. The product is also supplied with either a click type or pop-up waste (see model), and a ½” BSP (F) nut and NBR washer to adapt the side valve inlet connections. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies (brass bodies with various finishes). Incorporating quarter turn ceramic disc and various operating members. The spout outlet incorporates a plastic aerator. The product is supplied with nylon braided EPDM lined flexible hose assemblies incorporating ½” captive nut end connections on both ends or at one end and M10 at the other. The hoses are intended to connect between the side body headworks and the spout junction. The product is also supplied with a pop-up waste, and a ½” BSP (F) nut and NBR washer to adapt the side valve inlet connections. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Four hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn ceramic disc head work with single lever operating members (model WAI4BSMXX) and self cancelling diverter to shower outlet. The fitting is supplied with Stainless steel braided PEX lined flexible connecting hoses. The spout outlets incorporate a plastic aerator. Product is supplied with a shower hose and handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted, spout outlet (brass body with various finishes - see model) incorporating a plastic aerator. The inlet incorporates an approved single check valve cartridge, however, the complete assembly has not been tested to demonstrate that it provides back flow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of spout outlets incorporating stainless steel bodies (various finishes) and a plastic aerator. Maximum operating temperature 60°C.
Range of wall mounted spout outlets incorporating brass bodies (various finishes) & plastic aerators. Maximum operating temperature 60°C.
Spout outlet with a brass body (chrome plated). The spout outlet incorporates a combined plastic flow regulator and aerator. Maximum operating temperature 60°C.
Range of wall mounted spout outlets with brass bodies (chrome plated). Product is supplied with various operating members and pop up click waste. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Range of filling loop assemblies consisting of an in-line isolation valve, in-line double check valve assembly which also incorporates an isolation valve (suitable for back flow protection against fluid category 3) and stainless steel braided EPDM lined hose. The isolation valves are operated via a single lever. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
‘Profine’ plastic bodied filter head incorporating EPDM ‘O’-rings for use with filter cartridges (not supplied).For use with LLDPE tube (manufactured to DIN 8072). All models can be specified with or without an integral bracket. Maximum working pressure 6.0 bar. Cold water use only.
Range of inline water filter cartridges with polypropylene housing with a carbon block filter. Maximum working pressure 8.5 Bar Cold water use only.
Range of brass, chrome plated brass or DZR brass compression fittings for use with copper pipe only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of M type press fittings with TP2 copper bodies and EPDM ‘O’-rings, for use with TP2 copper pipe to EN1057. Above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Copper brazed micro plate heat exchanger with copper and stainless-steel (316/1.4401) plates. Maximum working pressure 25.0 Bar. Maximum operating temperature 100°C
Range of ice making machines. The inlet supply is controlled by a solenoid valve. Inlet hose supplied. Maximum working pressure 5.0 bar. Cold water use only.
Range of water meter assemblies which incorporating DZR brass bodies, spherical valve and pressure reducing valve (1.5 to 6.0 bar range). The products incorporate two approved, in-line single check valve cartridges, (verified by test, suitable for backflow protection against Fluid Category 3). Fitting is also supplied with a pressure guage. Maximum working pressure 10.0 bar. Cold water use only.
Range of meter boxes incorporating a plastic manifold arrangement consisting of a stop valve with non-rising spindle , check valve (however the complete assembly has not been tested to demonstrate it provides adequate backflow) and concentric meter port. Some models incorporate a drain off or blacking plug. Connections can be compression or push fit (see model). For use with PE8-0 pipe to BS EN 12201 and copper to EN 1057. Maximum working pressure 16.0 bar. Cold water use only.
Bath spout incorporating a brass body (various finishes), EPDM ‘O’-rings and a plastic flow straightener. Maximum operating temperature 60°C
Page 66 of 427
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.