Directory Search Results

Print List

#240904728

Urinal flush control valve with the flow controlled by a solenoid valve and operated via a PIR sensor. Maximum working pressure 6 bar. Maximum operating temperature 23°C

Section:
1307 Flushing Mechanisms
Section Subtitle:
Urinals.
WRAS Approval Number:
240904728
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
15mm compression
Marking:
Cistermiser on body.
Installation Requirements:
R001 R075
Expiry date:
30/09/2029
Model:
IRC2
Product Images

Approval Holder:
Cistermiser Ltd
Company Name
Cistermiser Ltd
Address
Unit 1 Woodley Park Estate, 59/69 Reading Road Woodley
Postcode
RG5 3AN
Country
United Kingdom
General Email
jake.felstead@cistermiser.co.uk

View All Listings by this Company

Print This Approval


#240902710

Range of wall mounted, electronic tap assemblies which are set within a mirrored cabinet unit. The flow is controlled by a solenoid valve assembly and is activated via infra-red non touch operation. The units also incorporate a soap dispenser and hand dryer or paper towel dispenser. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C

Section:
1340 Hand-wash units
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
3/8” BSP (M)
Marking:
Delabie on front of mirror cabinet. Delabie, model and other technical information on adhesive label on body of installation unit.
Installation Requirements:
R001 R040
Expiry date:
30/09/2029
Model:
Mirror cabinet with 4 functions: 510203 (mirror, soap dispenser, hand dryer and electronic tap). 510204 (mirror, soap dispenser, hand dryer and electronic tap). 510205 (mirror, soap dispenser, paper towel dispenser and electronic tap). 510206 (mirror, soap dispenser, paper towel dispenser and electronic tap). Unit for installation behind a mirror: 510205I (soap dispenser, paper towel dispenser and electronic tap) Model added October 2024 Unit for installation behind a mirror 510203I (Electronic tap, soap dispenser and hand dryer)
Product Images

Approval Holder:
Delabie UK Ltd.
Company Name
Delabie UK Ltd.
Address
18,rue du Maréchal Foch Friville Escarbotin
Postcode
80210
Country
France
General Email
sebastien.spriet@delabie.fr

View All Listings by this Company

Print This Approval


#240902017

Range of copper or stainless-steel brazed heat exchangers available with various number of plates as listed below. Maximum working pressure 25.0 Bar (copper brazed models). Maximum working pressure 10.0 Bar (stainless steel brazed models). Maximum operating temperature 100.0°C.

Section:
1350 Heat Exchangers
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
4G3/4 models = ¾” BSP, 4AYB models = 8mm porthole (XB05H-1-xx-2STS_10/10_S1_4AYB Only) or 15mm porthole for all other models, 4clip models = 15mm ID clip connection.
Marking:
DANFOSS logo, model code, date of manufacture (YYYY/WW), PN and other technical data laser engraved into the body.
Installation Requirements:
R001
Expiry date:
30/09/2029
Model:
XB05M-1-xx-2CU_25/25_S1_4G3/4, XB05X-1-xx-2CU_25/25_S1_4G3/4, XB05H-1-xx-2CU_25/25_S1_4G3/4, XB05X-1-xx-2STS_10/10_S1_4G3/4, XB05H-1-xx-2STS_10/10_S1_4G3/4, XB05H-1-xx-2CU_25/25_S1_4AYB, XB05X-1-xx-2CU_25/25_S1_4AYB, XB05H-1-xx-2STS_10/10_S1_4AYB, XB05X-1-xx-2STS_10/10_S1_4AYB, XB05H-1-xx-2STS_10/10_S1_4AYB, XB05X-1-20-2CU_25/25_S1_4Clip, XB05X-1-20-2STS_10/10_S1_4Clip, XB05H-1-xx-2CU_25/25_S1_4Clip, XB05H-1-xx-2STS_10/10_S1_4Clip. XB05 - frame size (XB05 = 312 mm x 76 mm) M, X, H - heatplate corrugation (different dimple design) - 1 - one pass heat exchanger (all XB05 range is one pass) “xx” = number of plates from 8 to 70. HP material = always 2; meaning material of heatplate which is always 1.4404. Brazing material = Stainless steel brazed = StS, Copper brazed = Cu. Pressure = approved pressure for primary and secondary channels (for XB05 is 25 bar when copper brazed and 10 bar when stainless steel brazed visible from application list in 202_f2). Connection configuration = position of connections (on XB05 only S1 applies). Connection type = G3/4 threaded ¾ connections AYB -no connections. Clip - tailormade solder and / or clip connections; usually tailormade for specific customer.
Product Images

Approval Holder:
Danfoss A/S
Company Name
Danfoss A/S
Address
Nordborgvej 81 6430 Nordborg
Country
Denmark
Phone
+74 88 22 22
General Email
danfoss@danfoss.com

View All Listings by this Company

Print This Approval


#240904726

‘PREMIX’ range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both the domestic hot water and primary circuit are controlled via spherical valves. Maximum working pressures: Primary circuit: 2.5 bar, Secondary circuit 10.0 bar. Maximum operating temperature both circuits: 80°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
240904726
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
22mm compression (Primary Circuit) 15mm compression (Secondary Circuit)
Marking:
E.C.A. on front cover. E.C.A, model and technical information including KW rating on adhesive label on body.
Installation Requirements:
R001 R360
Expiry date:
30/09/2029
Model:
8116350010 CALORA PREMIX 24 HM ERP UK 8116484110 CALORA PREMIX 14 HM ERP UK 8116487110 CALORA PREMIX 20 HM ERP UK 8116356010 CALORA PREMIX 28 HM ERP UK 8116389010 CITIUS PREMIX 14 HM ERP UK 8116392010 CITIUS PREMIX 20 HM ERP UK 8116353010 CITIUS PREMIX 24 HM ERP UK 8116380010 CITIUS PREMIX 28 HM ERP UK 8116576110 Proteus Premix 42 HM DG ERP UK 8116550010 Proteus Premix 45 HM DG ERP UK
Product Images

Approval Holder:
Emas Makina Sanayi A.S.
Company Name
Emas Makina Sanayi A.S.
Address
Mustafa Kemal Blv. No:13 Keçiliköy Osb/Yunusemre Manisa
Postcode
45030
Country
Turkey
General Email
egecakmakci@emas.com.tr

View All Listings by this Company
Manufacturer:
Emas Makina Sanayi A.S.
Company Name
Emas Makina Sanayi A.S.
Address
Mustafa Kemal Blv. No:13 Keçiliköy Osb/Yunusemre Manisa
Postcode
45030
Country
Turkey
General Email
egecakmakci@emas.com.tr

View All Listings by this Company

Print This Approval


#240902009

Range of in-line water meters with either a brass or plastic composite body. The product incorporates a plastic strainer on the inlet. Maximum working pressure 16.0 Bar Maximum operating temperature 85.0°C

Section:
1505 Water Meters
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
See models
Marking:
DIEHL metering, model code and product information on dial face. Flow arrow on body.
Installation Requirements:
R001
Expiry date:
30/09/2029
Model:
Aries 15/110 Composite Body ¾” BSP (M) Aries 15/110 Brass Body ¾” BSP (M) Aries 20/130 Brass Body 1” BSP (M)
Product Images

Approval Holder:
Diehl Metering S.A.S & Diehl Metering Sp. Z o.o.
Company Name
Diehl Metering S.A.S & Diehl Metering Sp. Z o.o.
Country

View All Listings by this Company
Manufacturer:
Diehl Metering S.A.S & Diehl Metering Sp. Z o.o.
Company Name
Diehl Metering S.A.S & Diehl Metering Sp. Z o.o.
Country

View All Listings by this Company

Print This Approval


#240902018

Range of in-line water meters with brass bodies. The inlets incorporate a plastic filter. The outlets incorporate a non-return valve (not intended for or suitable for backflow protection). Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.

Section:
1505 Water Meters
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
¾” BSP (M), 1” BSP (M) & 1¼” BSP (M)
Marking:
Shenzhen Kaifa logo, date of manufacture (YYYY), model & technical info on meter face.
Installation Requirements:
R001
Expiry date:
30/09/2029
Model:
MA408K
Product Images

Approval Holder:
Shenzhen Kaifa Technology (Chengdu) Co., Ltd.
Company Name
Shenzhen Kaifa Technology (Chengdu) Co., Ltd.
Address
No 99 Tianquan Hi Tech Development Zone Chengdu PRC
General Email
xingweiyang@kaifa.com

View All Listings by this Company
Manufacturer:
Shenzhen Kaifa Technology (Chengdu) Co., Ltd.
Company Name
Shenzhen Kaifa Technology (Chengdu) Co., Ltd.
Address
No 99 Tianquan Hi Tech Development Zone Chengdu PRC
General Email
xingweiyang@kaifa.com

View All Listings by this Company

Print This Approval


#240902069

Range of in-line water meters with plastic bodies. The inlet incorporates a plastic filter. Maximum working pressure; 16 Bar Maximum operating temperature 50°C

Section:
1505 Water Meters
WRAS Approval Number:
240902069
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Note:
All models available in body lengths of 165, 170 and 190mm
Size:
1" BSP (M)
Marking:
Arad logo, Model and technical information on faceplate. Flow arrow on body.
Installation Requirements:
R001
Expiry date:
30/09/2029
Model:
PD GLADIATOR Q3=4 1124XXXX With 3P register 1132XXXX- With 3G register
Product Images

Approval Holder:
Arad GROUP Ltd.
Company Name
Arad GROUP Ltd.
Address
Kibbutz Dalia 1923900 Kibutzz Dalia
Country
Israel
Phone
+972-4-9897906
General Email
Dars@arad.co.il

View All Listings by this Company
Manufacturer:
Arad GROUP Ltd.
Company Name
Arad GROUP Ltd.
Address
Kibbutz Dalia 1923900 Kibutzz Dalia
Country
Israel
Phone
+972-4-9897906
General Email
Dars@arad.co.il

View All Listings by this Company

Print This Approval


#240904008

Range of ultrasonic remote transmission water meters with stainless steel body. The products incorporate a single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.

Section:
1505 Water Meters
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (M) & 1” BSP (M) Size added October & November 2024 ¾” BSP (M)
Marking:
Manufacturer’s logo, model, WRAS, flow arrow. Date of manufacture (MM/YY) and technical info on body.
Installation Requirements:
R001
Expiry date:
30/09/2029
Model:
LXCY-15 & LXCY-25 Model added October 2024 LXCY-20 3/4" BSP (M) Model added November 2024: LXCY_20 : 3/4" BSP (M)
Product Images

Approval Holder:
Sanchuan Wisdom Technology Co., Ltd.
Company Name
Sanchuan Wisdom Technology Co., Ltd.
Address
Sanchuan Hydraulic Industrial Park, Longgang Section, Hi-Tech Development Zone, Yingtan, Jiangxi, P.R.China

View All Listings by this Company
Manufacturer:
Sanchuan Wisdom Technology Co., Ltd.
Company Name
Sanchuan Wisdom Technology Co., Ltd.
Address
Sanchuan Hydraulic Industrial Park, Longgang Section, Hi-Tech Development Zone, Yingtan, Jiangxi, P.R.China

View All Listings by this Company

Print This Approval


#240902039

Range of VEGAPULS radar sensors for level measurement with plastic bodies. Cold water use only. Open outlet use only.

Section:
1530 Miscellaneous Fittings
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
See model key
Marking:
VEGA logo date of manufacturer (YYYY), serial number and other technical data on body
Installation Requirements:
R001
Expiry date:
30/09/2029
Model:
PSC21.ab-c-d-N-f-g-h-I VEGAPULS C 21 PSC22.ab-c-d- N -f-g-h-I VEGAPULS C 22 PSC23.ab-c-d- N -f-g-h-I VEGAPULS C 23 PS21.ab-c-d- N -f-g-h-I VEGAPULS 21 PS31.ab-c-d- N -f-g-h-I VEGAPULS 31 KEY FOR VEGAPULS C 21 ab = explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, RCM, EAC) VH ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 (Class II, III Division 1, 2) VB ATEX/UKEX/IEC; Gas, Encapsulation, Zone 1, 2 + Dust, Protection by enclosure, Zone 20, 21/22, 21, 22 SH EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 + Dust, intrinsic safety Zone 20, 20/21, 21, 22 SB EAC/SEPRO; Gas, encapsulation, Zone 1, 2 + Dust, encapsulation Zone 21, 22 TH CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, Intrinsic safety, Zone 20, 20/21, 21, 22 (not CCOE) TB CCOE, NEPSI, KTL, TIIS; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 (not CCOE) WH INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 WB INMETRO/IA; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 FB c-FM-us/c-CSA-us; Gas, encapsulation, Zone 1, 2 (Class I Division 2) + Dust, protection by enclosure, Zone 20, 20/21, 21, 22 (Class II, III Division 1) FR c-FM-us/c-CSA-us; Gas, non-incendive, Class I Division 2 + Dust-ignitionproof, Class II, III Division 1 c = Approved as overfill protection, which can be displayed as; X without W with (WHG, VLAREM) d = Ship approval, which can be displayed as; X without S with (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff / Pharmaceutical certificate, which can be displayed as; X without N with (NSF/ANSI/CAN 61) P with (NIH) F with (FDA, EG1935/2004) f = Thread process side / Cable side, which can be displayed as; G Thread G1½ / G1 N Thread 1½NPT / 1NPT R Thread R1½ / R1 g = Cable material / Length, which can be displayed as; A PUR / 5m (approx. 16ft) B PUR / 10m (approx. 32ft) H PUR / 15m (appr. 48ft) J PUR / 20m (appr. 64ft) C PUR / 25m (approx. 82ft) D PUR / individually selectable (acc. to CE, RCM, EAC) D PUR / individually selectable (acc. to c-FM-us, c-CSA-us) h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART W Four-wire Modbus S Three-wire SDI12 i = Sensor setting via smartphone and VEGA Tools app, which can be displayed as; X without B with KEY FOR VEGAPULS C 22 ab = Explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, c-FM-us, c-CSA-us, RCM, EAC) VH ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 (Class II, III Division 1, 2) VB ATEX/UKEX/IEC; Gas, Encapsulation, Zone 1, 2 + Dust, Protection by enclosure, Zone 20, 21/22, 21, 22 SH EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 + Dust, intrinsic safety Zone 20, 20/21, 21, 22 SB EAC/SEPRO; Gas, encapsulation, Zone 1, 2 + Dust, encapsulation Zone 21, 22 TH CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, Intrinsic safety, Zone 20, 20/21, 21, 22 (not CCOE) TB CCOE, NEPSI, KTL, TIIS; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 (not CCOE) WH INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 WB INMETRO/IA; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 FB c-FM-us/c-CSA-us; Gas, encapsulation, Zone 1, 2 (Class I Division 2) + Dust, protection by enclosure, Zone 20, 20/21, 21, 22 (Class II, III Division 1) FR c-FM-us/c-CSA-us; Gas, non-incendive, Class I Division 2 + Dust-ignition proof, Class II, III Division 1 c = Approved as overfill protection, which can be displayed as; X without W with (WHG, VLAREM) d = Ship approval, which can be displayed as; X without S with (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff / Pharmaceutical certificate, which can be displayed as: X without N with (NSF/ANSI/CAN 61) P with (NIH) F with (FDA, EG1935/2004) f = Process fitting, which can be displayed as; G Thread G1½ N Thread 1½NPT R Thread R1½ g = Cable material / length, which can be displayed as; A PUR / 5m (approx. 16ft) B PUR / 10m (approx. 32ft) H PUR / 15m (appr. 48ft) J PUR / 20m (appr. 64ft) C PUR / 25m (approx. 82ft) D PUR / individually selectable (acc. to CE, RCM, EAC) D PUR / individually selectable (acc. to c-FM-us, c-CSA-us) h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART W Four-wire Modbus S Three-wire SDI12 i = Sensor setting via smartphone and VEGA Tools app, which can be displayed as; X without B with KEY FOR VEGAPULS C 23 ab = explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, RCM, EAC) VH ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 (Class II, III Division 1, 2) VB ATEX/UKEX/IEC; Gas, Encapsulation, Zone 1, 2 + Dust, Protection by enclosure, Zone 20, 21/22, 21, 22 SH EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 + Dust, intrinsic safety Zone 20, 20/21, 21, 22 SB EAC/SEPRO; Gas, encapsulation, Zone 1, 2 + Dust, encapsulation Zone 21, 22 TH CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, Intrinsic safety, Zone 20, 20/21, 21, 22 (not CCOE) TB CCOE, NEPSI, KTL, TIIS; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 (not CCOE) WH INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 WB INMETRO/IA; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 FB c-FM-us/c-CSA-us; Gas, encapsulation, Zone 1, 2 (Class I Division 2) + Dust, protection by enclosure, Zone 20, 20/21, 21, 22 (Class II, III Division 1) FR c-FM-us/c-CSA-us; Gas, non-incendive, Class I Division 2 + Dust-ignitionproof, Class II, III Division 1 c = Approved as overfill protection, which can be displayed as; X without W with (WHG, VLAREM) d = Ship approval, which can be displayed as; X without S with (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff / Pharmaceutical certificate, which can be displayed as; X without N with (NSF/ANSI/CAN 61) P with (NIH) F with (FDA, EG1935/2004) f = Thread process side / Cable side, which can be displayed as; F Thread G1 M Thread 1NPT Q Thread R1 g = Cable material / length, which can be displayed as; A PUR / 5m (approx. 16ft) B PUR / 10m (approx. 32ft) H PUR / 15m (appr. 48ft) J PUR / 20m (appr. 64ft) C PUR / 25m (approx. 82ft) D PUR / individually selectable (acc. to CE, RCM, EAC) D PUR / individually selectable (acc. to c-FM-us, c-CSA-us) h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART W Four-wire Modbus S Three-wire SDI12 i = Sensor setting via smartphone and VEGA Tools app, which can be displayed as; X without B with KEY FOR VEGAPULS 21 / 31 ab = explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, c-FM-us, c-CSA-us, RCM, EAC) AX without, for Ex-free area (CE, UKCA, RCM) VC ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) SC EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 TC CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 WC INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 c = Approved as overfill protection, which can be displayed as; X Without W With (WHG, VLAREM) d = Ship approval, which can be displayed as; X Without S With (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff/Pharmaceutical certificate, which can be displayed as X Without N With (NSF/ANSI/CAN 61) P With (NIH) F With (FDA, EG1935/2004) f = Process fitting, which can be displayed as; G Thread G1½ N Thread 1½NPT R Thread R1½ g = Cable entry / connection, which can be displayed as; M M20x1.5 / Cable gland PA black (ø5-9mm), standard h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART i = Sensor setting via smartphone and VEGA Tools app X Without B With
Product Images

Approval Holder:
VEGA Grieshaber KG
Company Name
VEGA Grieshaber KG
Address
Am Hohenstein 113 Schiltach
Postcode
77761
Country
Germany
General Email
info.de@vega.com

View All Listings by this Company
Manufacturer:
VEGA Grieshaber KG
Company Name
VEGA Grieshaber KG
Address
Am Hohenstein 113 Schiltach
Postcode
77761
Country
Germany
General Email
info.de@vega.com

View All Listings by this Company

Print This Approval


#240902065

Range of ‘Thermowatt’ immersion heater elements incorporating brass or DZR heads with either a copper, stainless steel, alloy or titanium heating element and a black EPDM ‘O’-ring. Open outlet use only. Maximum operating temperature 99°C

Section:
1530 Miscellaneous Fittings
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
RT – 1.1/4” BSP (M) to 2.1/4” BSP (M) RF – 48 mm OD
Marking:
Thermowatt logo, Model, Voltage, Size and other information on cap.
Installation Requirements:
R001
Expiry date:
30/09/2029
Model:
Model Code: XXYZS Where XX denotes the boss type and can be replaced with any of the following: RT = Thread Type RF = Flange Type Where Y denotes the heating tube material and can be replaced with any of the following: 1 = Copper 2 = AISI 304 / AISI 304L 3 = AISI 321 4 = AISI 316 / AISI 316L 5 = Alloy 800 / Alloy 825 / Alloy 840 6 = Titanium 7 = AISI 309S 8 = AISI 310 Where Z denotes the brazing system and can be replaced with any of the following: A = Tin Alloy B = Silver Alloy C = Itek Brazing Where S denotes the surface enamelling and can be replaced with either of the following: S = Enamelled Blank = Not Enamelled
Product Images

Approval Holder:
Thermowatt S.p.A.
Company Name
Thermowatt S.p.A.
Address
Via San Giovanni Battista 21 Arcevia
Postcode
60011
Country
Italy
Phone
+39 0731988246
General Email
thermowatt@legalmail.it

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 621 of 854

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.