“<A> Press Copper M Profile” series press fittings with a copper body and EPDM ‘O’-rings, for use with copper pipe manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Press-Inox range of stainless-steel crimped fittings (‘M’ crimp profile) for use with stainless steel pipe (manufactured to EN10204). For above ground use only. Maximum working pressure: 16Bar. Maximum operating temperature: 100°C.
Range of copper brazed, stainless steel heat exchangers. Available with between 4 – 70 plates (see models). Maximum working pressure: 16.0 bar. Maximum operating temperature: 99°C.
Range of indirect heat interface units (HIU) providing heating and instantaneous hot water. The central heating and hot water is generated via plate heat exchangers. Maximum operating pressure 10 bar (primary and DHW secondary). Maximum operating pressure 2.5 bar CH secondary Maximum operating temperature 90°C
Range of water meters with epoxy coated cast iron bodies. Maximum working pressure 16.0 bar. Cold water use only.
SJC range of water meters with brass bodies and plastic turbines. The inlet incorporates a plastic filter. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of water meter manifolds with plastic bodies for use with PE80 pipe (manufactured to BS EN 12201). The inlets incorporate a spherical valve and a check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.
Range of water meter manifolds with plastic bodies for use with PE80 pipe (manufactured to BS EN 12201). The inlet incorporates a stop valve. Model MB77025AM Matrix Single (CV) incorporates a single check valve cartridge and model MB77025DCV Matrix Dual (DCV) incorporates two, single check valve cartridges however, the complete products have not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.
Range of water meter manifolds with plastic bodies. The inlets incorporate a stop valve. Model MB77025CG Matrix Single (CV) incorporates a single check valve cartridge and model MB77025CGDCV Matrix Dual (DCV) incorporates two, single check valve cartridges however, the complete products have not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.
Range of water meter manifolds with plastic bodies for use with PE80 pipe (manufactured to BS EN 12201) and copper pipe. The products incorporate a drain off valve, plastic strainer and a single check valve cartridge however, the complete products have not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.
Nova-Flo’ inline flow control device with a plastic body. The product is intended to restrict the flow of water to a bath or basin if water level reaches the overflow. Float located within the overflow pathway activate flaps on each inlet to restrict the flow prior to the taps being closed. Maximum working pressure: 12 Bar. Maximum working temperature: 60°C.
Range of plastic pressure sensors. Maximum working pressure: 15.99 Bar. Maximum operating temperature 90.0°C.
Bias chamber incorporating an EPDM diaphragm and ‘O’-ring with a brass body. Maximum working pressure 35.0 bar. Cold water use only.
Range of multistage and single stage water pumps with stainless steel bodies and impellers. Maximum working pressure 2.0 bar (AMS models), 4.0 bar (EDH & EMH models) 8.0 bar (LVS models). Maximum operating temperature 85°C
Range of pumps with stainless steel bodies. Maximum working pressure depends on model, please refer to model. Maximum operating temperature 65°C.
Range of pumps with a plastic body. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C.
Range of booster sets consisting of two or four electronically controlled pumps, stainless steel manifold, spherical valves, expansion vessels and pressure gauge/transducers and non-return valves. Maximum operating pressure 16 bar. Maximum operating temperature 23°C.
Circulation pump with a stainless steel body. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of brass ceiling mounted shower tubes, in a variety of finishes. For use with copper pipe to EN 1057. Maximum operating temperature 80.0°C
Range of shower handsets with (plastic bodies - various finishes Maximum operating temperature 60°C. Open outlet use only.
Page 497 of 555
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.