SI-55678 (shore hardness 50), SI-65678 (SH 60), SI-75678 (SH 70) & SI-85678 (SH 80) natural ‘O’ rings. SI-52109 (shore hardness 50), SI-62109 (SH 60), SI-72109(SH 70), SI-82109 (SH80) red coloured ‘O’ rings. SI-51501 (shore hardness 50), SI-61501 (SH 60), SI-71501(SH 70) & SI-81501(SH 80) blue coloured ‘O’ rings. Natural (appears white coloured), red or blue coloured, compression moulded silicone rubber ‘O’ rings. Shore hardness between 50 shore A and 80 shore A. Tested in-radii sizes between 0.5mm & 2.5mm. For use with water up to 85°C.
'Silicone-01 Heater Seal Ring'. White coloured, compression moulded Silicone ring. Shore hardness 70. Tested in-radius size 3.4mm. For use with water up to 85°C.
'Silicone-02 Sealing Gasket'. Natural (appears white), compression moulded Silicone gasket. Shore hardness 70. Tested in-radius size 1.25mm. For use with water up to 85°C.
'LOCTITE® 2700™'. Green coloured anaerobic adhesive. Apply as per manufacturer's technical data sheet dated November 2024. For use with water up to 85°C. These products are to be applied and cured in strict accordance with the manufacturer's instructions
Range of stop valves with plastic bodies. The valves incorporate a built in solenoid valve which is operated by a switch located on the valve or by a remote control. The leak detector supplied is not connected to any water pipe, is independent of the valve and is intended to be installed in the area at risk of leakage. It is intended to detect leakage and sends an electrical signal to close the valve. For use with copper pipe (manufactured to BS EN1057), PEX pipe (manufactured to BS7291-3) and PB pipe (manufactured to BS7291 -2). Maximum working pressure 10.0 bar. Cold water use only
'+GF+ PVC-C'. Grey coloured, injection moulded PVC-C fittings. For use with water up to 60°C.
Range of wall mounted single hole, single outlet, fixed, electronically controlled tap assemblies (chrome plated brass bodies). Flow is controlled via an infra-red activated solenoid valve. Maximum working pressure 8.0 Bar Maximum operating temperature 45.0°C
Range of wall mounted single hole, single outlet, fixed, electronically controlled tap assemblies (chrome plated brass bodies). Flow is controlled via an infra-red activated solenoid valve. Maximum working pressure 8.0 Bar Maximum operating temperature 45.0°C
Single hole, single outlet (fixed) electronically controlled tap assembly. The flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator, and products are supplied with interconnecting stainless steel braided silicone lined flexible hose assemblies. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C.
Side and bottom entry BS1212 - 3 compact type float operated valve for WC flushing cisterns Maximum operating pressure 14 bar. Maximum operating temperature 23°C
Bottom entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. Maximum working pressure 10.0 bar. Cold water use only. The inlet incorporates a strainer. Maximum working pressure 10.0 bar. For use with cold water only
The range of WC cisterns incorporating a BS 1212-4:2016 side entry or bottom entry float operated inlet valve providing a Type AG air gap arrangement and a flush outlet valve operated via a push button assembly for either full or reduced flush. Maximum operating pressure 10.0 bar. Cold water use only.
Concealed BS EN 14055: 2018 WC flushing cistern incorporating a side or bottom compact type float operated inlet valve providing a Type AG air gap with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of 4 litres. The cistern can be operated by touch free electronic or manual push button / push plate options. The supply hose incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
Concealed BS EN 14055: 2018 WC flushing cistern incorporating a side or bottom entry compact type float operated inlet valve providing a Type AG air gap with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern can be operated by touch free electronic or manual push button / push plate options. Maximum working pressure 10.0 bar. Cold water use only.
Range of wall hung concealed WC flushing cisterns with a BS 1212-4 float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a push button assembly. Maximum working pressure - 10 Bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Concealed BS EN 14055: 2018 WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5) with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of 4 litres. The cistern can be operated by touch free electronic or manual push button / push plate options. The supply hose incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
DC type pipe interrupter with a permanent atmospheric vent (DZR brass body) incorporating a flow regulator at the inlet and brass shroud. Maximum working pressure 6.0 bar. Cold water use only.
Page 482 of 578
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.