#2305342

Range of stainless-steel plate heat exchangers. Maximum working pressure 10 bar. Maximum operating temperature 90°C.

Section:
1350 Heat Exchangers
Size:
17.05mm hole primary & 10.55mm hole secondary.
Marking:
'Original Quality' symbol (registered trade-mark of Bosch) and technical information on body.
Installation Requirements:
R001
Expiry date:
31/05/2028
Model:
C-PHE 10, 12, 14, 16, 18, 20, 22, 24, 26, 28, 30 & 32.
Product Images

Approval Holder:
Bosch Termoteknik Isitma ve Klima Sanayi ve Ticaret A.S.
Company Name
Bosch Termoteknik Isitma ve Klima Sanayi ve Ticaret A.S.
Address
Organize Sanayi Bolgesi
Postcode
45030 Manisa,
Country
Turkey
Phone
0090 236 226 1366
General Email
gulsah.colak@tr.bosch.com

View All Listings by this Company
Manufacturer:
Bosch Termoteknik Isitma ve Klima Sanayi ve Ticaret A.S.
Company Name
Bosch Termoteknik Isitma ve Klima Sanayi ve Ticaret A.S.
Address
Organize Sanayi Bolgesi
Postcode
45030 Manisa,
Country
Turkey
Phone
0090 236 226 1366
General Email
gulsah.colak@tr.bosch.com

View All Listings by this Company

Print This Approval


#2306067

‘G5 BC’ range of command centres that provide instant near boiling and chilled water (both filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The products are supplied with a filter cartridge. The products can also be supplied with a hot water booster and/or a venturi system to provide mains cold water combined with water from the hot water tank (see model). Maximum working pressure 5.0 bar. Maximum operating temperature 100˚C. Cold supply only.

Section:
1365 Heaters
Section Subtitle:
Electric instantaneous, open outlet, mains fed.
WRAS Approval Number:
2306067
Size:
Stainless steel braided PEX lined flexible hose assembly incorporating a ½” captive nut end connection
Marking:
Zip and Hydrotap on body. ZIP, model and maximum pressure and technical information on adhesive label on inside of body.
Installation Requirements:
R001 R007 R008 R009 R040 R150 R170
Expiry date:
30/06/2028
Proviso:
The non ‘NS’ suffix models listed on this approval fall under the scope of the GB Biocidal Products Regulations (GB BPR) by either incorporating or producing an active substance and/or incorporating a treated article. The product(s) has/have been judged only against the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. The decision of the Scheme to list them is not to be taken as any guide as to their effectiveness to do the job for which the active substance and/or treated article is present. WRAS accepts no liability for the material meeting the requirements of the GB Biocidal Products Regulations.
Model:
Command Centre UK HydroTap Mains models: H50084000UKNS: G5 BC Home M, H50002000UKNS: G5 BC20 M (with or without booster), H50004000UKNS: G5 BC60 M (with or without booster), H50084000UK: G5 BC Home M, H50002000UK: G5 BC20 M (with or without booster), H50004000UK: G5 BC60 M (with or without booster). Command Centre UK HydroTap Venturi models: H50092000UKNS: G5 BC Home H, H50021000UKNS: G5 BC20 H (with or without booster), H50023000UKNS G5 BC60 H (with or without booster), H50092000UK: G5 BC Home H, H50021000UK: G5 BC20 H (with or without booster), H50023000UK G5 BC60 H (with or without booster).
Product Images

Approval Holder:
Zip Heaters UK Ltd T/A Zip Water UK
Company Name
Zip Heaters UK Ltd T/A Zip Water UK
Address
Trafalgar House, Trafalgar Business Park, Dereham
Postcode
NR19 1JG
Country
United Kingdom
Phone
0345 600 5005
General Email
sebastian.ducker@zipwater.co.uk

View All Listings by this Company
Manufacturer:
Zip Industries (Aust) Pty Ltd.
Company Name
Zip Industries (Aust) Pty Ltd.
Address
67 Allingham Street Condell Park NSW 2200
Country
Australia
General Email

View All Listings by this Company

Print This Approval


#2306068

‘G5 BCS’ range of command centres that provide instant near boiling, sparkling and chilled water (all filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The products incorporate a pressure reducing valve (adjustable outlet pressure between 2.25 and 2.75 bar) on the supply to the carbonator unit. The carbonator inlet incorporates a non-return valve. The products are supplied with a filter cartridge. The products can also be supplied with a hot water booster and/or a venturi system to provide mains cold water combined with water from the hot water tank (see model). Maximum inlet supply pressure 5.0 bar. Maximum operating temperature 100˚C. Cold supply only.

Section:
1365 Heaters
Section Subtitle:
Electric instantaneous, open outlet, mains fed.
WRAS Approval Number:
2306068
Size:
Stainless steel braided PEX lined flexible hose assembly incorporating a ½” captive nut end connection.
Marking:
Zip and Hydrotap on body. Serial number containing date of manufacture (YYYY/MM/DD) and manufacturing code on adhesive label inside cover.
Installation Requirements:
R001 R007 R008 R009 R040 R160 R170
Expiry date:
30/06/2028
Proviso:
The product listed on this approval fall under the scope of the GB Biocidal Products Regulations (GB BPR) by either incorporating or producing an active substance and/or incorporating a treated article. The product(s) has/have been judged only against the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. The decision of the Scheme to list them is not to be taken as any guide as to their effectiveness to do the job for which the active substance and/or treated article is present. WRAS accepts no liability for the material meeting the requirements of the GB Biocidal Products Regulations.
Model:
Command Centre UK HydroTap Mains models: H50083000UK - G5 BCS Home M, H50060000UK - G5 BCS20 M (with or without booster), H50062000UK - G5 BCS60 M (with or without booster). Command Centre UK HydroTap Venturi models: H50090000UK - G5 BCS Home H, H50074000UK - G5 BCS20 H (with or without booster), H50075000UK - G5 BCS60 H (with or without booster).
Product Images

Approval Holder:
Zip Heaters UK Ltd T/A Zip Water UK
Company Name
Zip Heaters UK Ltd T/A Zip Water UK
Address
Trafalgar House, Trafalgar Business Park, Dereham
Postcode
NR19 1JG
Country
United Kingdom
Phone
0345 600 5005
General Email
sebastian.ducker@zipwater.co.uk

View All Listings by this Company
Manufacturer:
Zip Industries (Aust) Pty Ltd.
Company Name
Zip Industries (Aust) Pty Ltd.
Address
67 Allingham Street Condell Park NSW 2200
Country
Australia
General Email

View All Listings by this Company

Print This Approval


#2306060

Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The products are supplied with a temporary filling loop which incorporates a combined isolation valve and double check valve assembly (suitable for backflow protection against Fluid Category 3), stainless steel braided EPDM lined flexible hose assembly and an isolation valve. The secondary circuit (DHW) incorporates a stainless-steel strainer. The primary circuit incorporates isolation valves on the flow and return. Maximum working pressures: DHW: 10.0 Bar CH:2.5 Bar Maximum operating Temperatures: DHW: 65.0°C CH: 85.0°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2306060
Size:
DHW: 15mm compression CH: 22mm compression
Marking:
Vailant on front cover. Vailant, Model,Pressure, Temperature and other information on adhesive label on rear of body
Installation Requirements:
R001 R140 R360
Expiry date:
30/06/2028
Model:
VUW 20/26CS/1-5 (N-GB) ecoTEC plus 826 VUW 25/32CS/1-5 (N-GB) ecoTEC plus 832 VUW 30/36CS/1-5 (N-GB) ecoTEC plus 836 VUW 30/40CS/1-5 (N-GB) ecoTEC plus 840 VUI 30/40CS/1-5 (N-GB) ecoTEC plus 940
Product Images

Approval Holder:
Vaillant GmbH
Company Name
Vaillant GmbH
Address
Berghauser Strasse, 40 D-42859 Remscheid
Country
Germany
Phone
Tel: +49 2191 182126

View All Listings by this Company
Manufacturer:
Vaillant Industrial UK Ltd
Company Name
Vaillant Industrial UK Ltd
Address
Nottingham Road Belper Derbyshire
Postcode
DE56 1JT
Phone
01773 824141

View All Listings by this Company

Print This Approval


#2307329

Preheat accessory assembly for connection to the domestic hot water circuit of a combination boiler. Incorporates flow sensor, flow restrictor, flow silencers, pre-heat sensor and filter. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Section:
1478 Heater
Section Subtitle:
Combination boilers - accessories and components.
WRAS Approval Number:
2307329
Size:
15mm compression.
Marking:
Bosch and date of manufacture (MM/YY).
Installation Requirements:
R001
Expiry date:
31/07/2028
Model:
7-716-192-735: GREENSTAR CDI COMPACT ERP DHW Solar Pre-Heat Kit.
Product Images

Approval Holder:
Worcester Bosch
Company Name
Worcester Bosch
Address
Cotswold Way Warndon Worcester
Postcode
WR4 9SW
Country
United Kingdom
Phone
+44 1905 752761
General Email
ian.sharp@uk.bosch.com

View All Listings by this Company
Manufacturer:
Worcester Bosch
Company Name
Worcester Bosch
Address
Cotswold Way Warndon Worcester
Postcode
WR4 9SW
Country
United Kingdom
Phone
+44 1905 752761
General Email
ian.sharp@uk.bosch.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 458 of 801

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.