Directory Search Results

Print List

#260204002

Range of below ground water meter manifolds with a plastic body and a spherical valve at the inlet. Models incorporate an approved single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. For use with PE80 blue pipe (manufactured to BS EN 12201). Maximum working pressure 12.5 bar. Cold water use only.

Section:
1510 Water Meter Manifolds
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Please refer to model.
Marking:
EBCO on manifold. EBCO & flow arrow on bracket.
Installation Requirements:
R001 R008
Expiry date:
28/02/2031
Model:
MB2012525BM: EBCO Raised Manifold 25mm Pushfit. MB2010303BM: EBCO Raised Manifold ¾” BSP. MB2011010BM: EBCO Raised Manifold 25mm Blue MDPE Pipe.

Approval Holder:
Atlantic Plastics Ltd.
Company Name
Atlantic Plastics Ltd.
Address
Coytraherne Close, Brackla, Bridgend
Postcode
CF31 2AX
Country
United Kingdom
Phone
01656672628
General Email
rhodgkiss@atplas.co.uk

View All Listings by this Company

Print This Approval


#250904703

Range of flow sensors incorporating either brass, plastic or stainless steel bodies & EPDM ‘O’-rings. Maximum working pressure 10.0 bar for models VVXA, VVXC, VVXB. Maximum working pressure 16.0 bar for models VVXD & VVXE. Maximum operating temperature 90°C.

Section:
1530 Miscellaneous Fittings
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
See models.
Marking:
Sika logo, pressure, temperature, other tech info on body; flow arrow on body.
Installation Requirements:
R001
Expiry date:
30/09/2030
Model:
VVXA Vortex Flow Sensor Type VVX15 Vortex Flow Sensor nominal size 15. Body material PPS, G ¾ male or ½” NPT male VVXC Vortex Flow Sensor Type VVX20 Vortex Flow Sensor nominal size 20. Body material PPS G 1 male or ¾” NPT male or Quick-Fasten male/female VVXB Vortex Flow Sensor Type VVX25 Vortex Flow Sensor nominal size 25. Body material PPS G 1¼ male or 1” NPT male VVXD Vortex Flow Sensor Type VVX32 Vortex Flow Sensor nominal size 32. Body material brass or stainless steel G 1½ male or 1½” NPT male VVXE Vortex Flow Sensor Type VVX40 Vortex Flow Sensor nominal size 40. Body material brass or stainless steel G 2 male or 2” NPT male • digit 1,2,3: Designation of the series o VVX >>> VVX series • digit 4: nominal diameter o A >>> DN 15 for type VVX15 o C >>> DN 20 for type VVX20 o B >>> DN 25 for type VVX25 o D >>> DN 32 for type VVX32 o E >>> DN 40 for type VVX40 • digit 5,7,8,9,10,11,12,13,14,15: Device configuration • digit 6: Private label o S >>> SIKA (standard) o E >>> SIKA (standard) with ETL marking • digit 4 and 16: tube material / process connection o A and 4 >>> PPS – G 3/4 male thread o A and C >>> PPS – ½”NPT male thread o C and P >>> PPS – Quick-Fasten connection o C and 7 >>> PPS – G 1 male thread o C and 8 >>> PPS – 3/4" NPT male thread o B and 6 >>> PPS – G 1 1/4 male thread o B and E >>> PPS – 1” NPT male thread o D and U >>> Brass – G 1 1/2 male thread o D and 0 >>> Brass – 1½" NPT male thread o D and M >>> Stainless steel – G 1 1/2 male thread o D and Y >>> Stainless steel – 1½" NPT male thread o E and X >>> Brass – G 2 male thread o E and 9 >>> Brass – 2" NPT male thread o E and O >>> Stainless steel – G 2 male thread o E and Z >>> Stainless steel – 2" NPT male thread

Approval Holder:
SIKA Systemtechnik GmbH
Company Name
SIKA Systemtechnik GmbH
Address
Struthweg 7-9 Kaufungen
Postcode
34260
Country
Germany
Phone
+49 5605 803 652
General Email
grass@sika.net

View All Listings by this Company

Print This Approval


#241102725

Range of multistage and single stage water pumps with stainless steel bodies and impellers. Maximum working pressure 2.0 bar (MS(s) models), 4.0 bar (AM(E) models) Maximum operating temperature 85°C

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
241102725
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Please refer to model.
Marking:
TERAL, model, size & technical information on date label on body. Flow arrow on cover.
Installation Requirements:
R001 R415
Expiry date:
30/11/2029
Model:
MS(m)XXX-XX-E 1.m: different phase. --m: single phase, none: three phases 2.XXX: Rated flow (L/min) 3.XX: Rated power(kW). 4.E: E type end connection mode and size -- Rated flow(70-120m3/h): G1¼"XG1" -- Rated flow(210m3/h): G1½"XG1¼" -- Rated flow (370 m3/h): G2"XG1¼ AM(E) XXxXX (B) X/X-X XX(S) 1. E: Intelligent Type 2. XX: Inlet diameter (mm), range: 25,32,40,50 mm. 3. XX: Outlet diameter (mm), range: 25,32,40,50 mm. 4. B: alternative pump group 4. X/X: number of impeller /number of smaller impeller (if any) 5. X: motor frequency 6. XX: Rated power(kW) 7. S: different phase (S: single phase, none: three phases.)

Print This Approval


#250902720

Range of multistage centrifugal pumps with stainless-steel housings, stainless-steel impellers and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
250902720
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
DN25 - DN200 flanged.
Marking:
Dooch, model, serial number and technical info on data plate on body.
Installation Requirements:
R001 R415
Expiry date:
30/09/2030
Proviso:
The discharge from the drain core must be made via a type AA, AB or AD air gap, or in accordance with EN 1717.
Model:
XRLNa-b-c-d Where: XRL = model. With N = Wetted metallic material in SUS316L, Without N = Wetted metallic material in SUS304. a = Rated flow in m³/h (1 – 255). DN25 = 1-3. DN32 = 4-5. DN40 = 10. DN50 = 15-20. DN65 = 32. DN80 = 45. DN100 = 64 or 95. DN150 = 125-155. DN200 = 185-255. b = Number of impellers (stages 1 – 36). DN25 & DN32 models with 1 – 36 stages. DN40 models with 1 – 22 stages. DN50 models with 1 – 17 stages. DN65 models with 1 – 14 stages. DN80 models with 1 – 13 stages. DN100 models with 1 – 8 stages. DN150 models with 1 – 10 stages. DN200 models with 1 – 8 stages. c = Number of cutting impellers (0 – 3). (Note: c can be omitted when c = 0.) d = DN size (DN25 – DN200). (Note: d can be omitted.) E.g., XRL32-7-2-DN65 denotes: Pump is made of SUS304, rated flow 32 m³/h, 7 impellers, 2 cutting impellers and size DN65.

Approval Holder:
SHANGHAI SINO-KOREA DOOCH PUMP MFG. CO., LTD
Company Name
SHANGHAI SINO-KOREA DOOCH PUMP MFG. CO., LTD
Address
No 239 Zhangliantang Rd Liantang Ind Park Qingpu District Shanghai City China

View All Listings by this Company
Manufacturer:
ZHONGHAN DOOCH PUMP(HUZHOU)CO., LTD.
Company Name
ZHONGHAN DOOCH PUMP(HUZHOU)CO., LTD.
Address
NO 669 DAYANG ROAD KANGSHAN STREET HUZHOU ZHEJAING CHINA

View All Listings by this Company

Print This Approval


#250904702

Range of pumps, with stainless steel bodies, impellers and shaft. Maximum working pressure 10.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
250904702
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
See models.
Marking:
Wilo, made in Korea, Model No., Serial No., website address, & other tech info on data label. Wilo printed on control panel.
Installation Requirements:
R001 R415
Expiry date:
30/09/2030
Model:
PBI-L203EA - Suction 25A(1”) Discharge 25A(1”) PBI-L204EA - Suction 25A(1”) Discharge 25A(1”) PBI-L205EA - Suction 25A(1”) Discharge 25A(1”) PBI-L402EA - Suction 32A(1 1/4”) Discharge 25A(1”) PBI-L403EA - Suction 32A(1 1/4”) Discharge 25A(1”) PBI-L404EA - Suction 32A(1 1/4”) Discharge 25A(1”) PBI-L405EA - Suction 32A(1 1/4”) Discharge 25A(1”) PBI-L802EA - Suction 40A(1 1/2”) Discharge 32A(1 1/4”) PBI-L803EA - Suction 40A(1 1/2”) Discharge 32A(1 1/4”) PBI-LD203EA - Suction 25A(1”) Discharge 25A(1”) PBI-LD402EA - Suction 32A(1 1/4”) Discharge 25A(1”) PBI-LD403EA - Suction 32A(1 1/4”) Discharge 25A(1”) PBI-LD404EA - Suction 32A(1 1/4”) Discharge 25A(1”) PBI-LD405EA - Suction 32A(1 1/4”) Discharge 25A(1”) PBI-LD802EA - Suction 40A(1 1/2”) Discharge 32A(1 1/4”) PBI-LD803EA - Suction 40A(1 1/2”) Discharge 32A(1 1/4”) 1 - Series PBI-L: Electronic Boosting Pump Variable Speed Pump(Inverter Pump). 2 - Number of Pumps None/blank : Single Type (One Pump), D: Duplex Type (Two Pumps). 3 - Rated Flow capacity 2 : 2㎥/hr, 4 : 4㎥/hr, 8 : 8㎥/hr. 4 - Number of Impellers 02 : 2 Impellers, 03 : 3 Impellers, 04 : 4 Impellers, 05 : 5 Impellers. 5 - Power 60Hz L: 110V ~, J: 120V ~ , 127V~, M: 220V~ D: 110V/220V~, I: 220/380V 3~, T: 220V 3~, U: 380V 3~, N: 440V 3~, R: 480V 3~. 50Hz Z: 110V ~, C: 120V ~, 127V~, E: 220V ~, F: 110V/220V ~, G: 220/380V 3~, H: 220V 3~, Q: 380V 3~, Y: 440V 3~. 6 - Automatic mode. None/blank : non automatic models A: models which equips themselves with components that are responsible for automatic mode.

Approval Holder:
WILO Pumps Ltd.
Company Name
WILO Pumps Ltd.
Address
46, Mieumsandan 1-ro, Gangseo-gu, Busan, Republic of Korea, 46730

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 413 of 494

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.