Range of lever operated spherical valves with brass bodies (chromium plated), incorporating chromium plated balls and PTFE seats. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of spherical valves with nickel plated brass bodies, incorporating PTFE seats and chromium plated brass balls. Valves are operated by butterfly type handles. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of spherical valves with stainless steel bodies, chrome plated brass ball and PTFE seats. Maximum working pressure 68.9Bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of hand wheel operated gate valves with blue epoxy coated ductile iron bodies and EPDM wedge. Maximum working pressure 16.0 Bar. Maximum operating temperature 65.0°C.
Range of resilient seated gate valves incorporating blue epoxy coated ductile iron body and EPDM gaskets with a handwheel operating member. Maximum working pressure 16.0 Bar Maximum operating temperature 23.0°C
Range of gate valves incorporating blue epoxy coted ductile iron bodies, ductile iron wedges encapsulated in EPDM and an EPDM gasket and seal. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of screw down stop valves with brass bodies, NBR seals and ‘T’ type operating members. Compression connection to be used with copper pipe EN1057 only. Maximum working pressure 16 bar. Maximum operating temperature 85°C.
Range of manually operated balancing valves with bronze bodies, DZR brass disc and EPDM rubber 'O’-rings. Both models have test points. The F9506 models also have a drain point on the high-pressure test side. Maximum working pressure 25.0 bar. Maximum operating temperature 100°C.
Range of bedpan washing & disinfection machines. The flow is controlled by a solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure - See models Maximum operating temperature - 90 °C
Range of commercial washing machines with flow controlled by solenoid valves and discharged via type AB air gap assembly (verified by test - suitable for backflow protection against fluid category 5). The inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5 Bar. Maximum operating temperature 60°C.
Range of in-line electrolytic scale inhibitors with copper bodies, for use with copper pipe manufactured to BS EN 1057 Maximum working pressure 20.0 bar. Cold water use only
Range of inline water conditioners with stainless steel bodies and catalytic alloy core. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
‘G5 C’ command centre providing chilled (filtered) water via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The products are supplied with a filter cartridge. The inlet to the command centre incorporates two approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum inlet supply pressure 5.0 bar. Cold water use only.
‘G5 CS’ command centre providing chilled or chilled sparkling water (both filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The product incorporates a pressure reducing valve (adjustable outlet pressure between 2.25 and 2.75 bar) on the supply to the carbonator unit. The carbonator inlet incorporates a non-return valve. The product is supplied with a filter cartridge. The inlet to the command centre incorporates two approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum inlet supply pressure 5.0 bar. Cold water use only.
'ELECTROCOAT BP 1119'. Factory applied, black coloured Bituminous Paint. Apply as per manufacturer's TDS Document No: 'ECL/ TDS / BP-1119-Bituminous Paint', Issue Date '10-Aug-20', Version No: '01'. Cure for 12 minutes at 45°C, followed by 10 hours at 28°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘PRIMER NATZINC EP9015 SC PART A’ Primer for use with ' HYDRALFUN AC BLEU PAM RAL5005-CZL8190 ' top-coat. Factory applied, blue coloured (once applied) primer and finish-coat. Mix base:hardener of primer in a 100:10 weight ratio and apply as per manufacturer’s TDS February 2024. Then apply top-coat as per manufacturer’s TDS February 2024. Cure for 21 days@23°C. For use with water up to 50°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Hempathane PW 35660 blue & off-white`. Factory applied, two-component polyurethane liquid coating consisting of a base and curing agent. Mix base and curing agent in a 3:1 volume ratio and apply as per product data sheet dated December 2023. Cure for 7 days@20°C. For use with water up to 35°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Hempadur 35560 Cream'. Factory applied, two-component, cream coloured epoxy coating which can be applied as a one-coat or a two-coat system. Mix base and curing agent in a 6.8:2 volume ratio and apply as per manufacturer's Product Data Sheet dated 'December 2023'. Cure each coat for 7 days@20°C. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘Sikagard®-180’. Site applied, grey coloured, two-component epoxy coating consisting of Part A (grey coloured liquid) and Part B (colourless liquid). Mix Part A and Part B in a mass ratio of 87:13 and apply as per manufacturer's TDS 'MBS_CC-UAE/Pr_180_05_18/v9/02_22/v10/05_23/v11/01_24'. Cure coat 1 for 36 hours@20°C. Cure coat 2 for 21 days@20°C. For use with water up to 40°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'LOCTITE® SF 770™' (known as 'LOCTITE 770'). Site applied, clear cyanoacrylate primer. Apply as per manufacturer's technical data sheet dated May 2021. Cure for 30 seconds@20°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Page 399 of 555
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.