Directory Search Results

Print List

#240704026

Water hammer arrestor with brass body and EPDM ‘O’ ring. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.

Section:
1530 Miscellaneous Fittings
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (M).
Marking:
Rubinetteria logo, Made in Italy, temperature and pressure cast on body.
Installation Requirements:
R001
Expiry date:
31/07/2029
Model:
145.12 - Stopshock 145.
Product Images

Approval Holder:
Rubinetteria Malgorani Pietro Srl
Company Name
Rubinetteria Malgorani Pietro Srl
Address
Via per Invorio 24 Colazza
Postcode
28010
Country
Italy
Phone
+39335453853
General Email
contact@malgorani.it

View All Listings by this Company
Manufacturer:
Rubinetteria Malgorani Pietro Srl
Company Name
Rubinetteria Malgorani Pietro Srl
Address
Via per Invorio 24 Colazza
Postcode
28010
Country
Italy
Phone
+39335453853
General Email
contact@malgorani.it

View All Listings by this Company

Print This Approval


#240704057

Water hammer arrestor with brass body and EPDM ‘O’ ring. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.

Section:
1530 Miscellaneous Fittings
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (M).
Marking:
CIM & Made in Italy on body.
Installation Requirements:
R001
Expiry date:
31/07/2029
Model:
CIM 1450 – Water Hammer shock absorber

Approval Holder:
Cimberio S.p.A
Company Name
Cimberio S.p.A
Address
Via Torchio, 57 San Maurizio d’Opaglio
Postcode
28017
Country
Italy
Phone
+39.0322.923001
General Email
tguidetti@cimberio.it

View All Listings by this Company

Print This Approval


#240902039

Range of VEGAPULS radar sensors for level measurement with plastic bodies. Cold water use only. Open outlet use only.

Section:
1530 Miscellaneous Fittings
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
See model key
Marking:
VEGA logo date of manufacturer (YYYY), serial number and other technical data on body
Installation Requirements:
R001
Expiry date:
30/09/2029
Model:
PSC21.ab-c-d-N-f-g-h-I VEGAPULS C 21 PSC22.ab-c-d- N -f-g-h-I VEGAPULS C 22 PSC23.ab-c-d- N -f-g-h-I VEGAPULS C 23 PS21.ab-c-d- N -f-g-h-I VEGAPULS 21 PS31.ab-c-d- N -f-g-h-I VEGAPULS 31 KEY FOR VEGAPULS C 21 ab = explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, RCM, EAC) VH ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 (Class II, III Division 1, 2) VB ATEX/UKEX/IEC; Gas, Encapsulation, Zone 1, 2 + Dust, Protection by enclosure, Zone 20, 21/22, 21, 22 SH EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 + Dust, intrinsic safety Zone 20, 20/21, 21, 22 SB EAC/SEPRO; Gas, encapsulation, Zone 1, 2 + Dust, encapsulation Zone 21, 22 TH CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, Intrinsic safety, Zone 20, 20/21, 21, 22 (not CCOE) TB CCOE, NEPSI, KTL, TIIS; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 (not CCOE) WH INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 WB INMETRO/IA; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 FB c-FM-us/c-CSA-us; Gas, encapsulation, Zone 1, 2 (Class I Division 2) + Dust, protection by enclosure, Zone 20, 20/21, 21, 22 (Class II, III Division 1) FR c-FM-us/c-CSA-us; Gas, non-incendive, Class I Division 2 + Dust-ignitionproof, Class II, III Division 1 c = Approved as overfill protection, which can be displayed as; X without W with (WHG, VLAREM) d = Ship approval, which can be displayed as; X without S with (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff / Pharmaceutical certificate, which can be displayed as; X without N with (NSF/ANSI/CAN 61) P with (NIH) F with (FDA, EG1935/2004) f = Thread process side / Cable side, which can be displayed as; G Thread G1½ / G1 N Thread 1½NPT / 1NPT R Thread R1½ / R1 g = Cable material / Length, which can be displayed as; A PUR / 5m (approx. 16ft) B PUR / 10m (approx. 32ft) H PUR / 15m (appr. 48ft) J PUR / 20m (appr. 64ft) C PUR / 25m (approx. 82ft) D PUR / individually selectable (acc. to CE, RCM, EAC) D PUR / individually selectable (acc. to c-FM-us, c-CSA-us) h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART W Four-wire Modbus S Three-wire SDI12 i = Sensor setting via smartphone and VEGA Tools app, which can be displayed as; X without B with KEY FOR VEGAPULS C 22 ab = Explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, c-FM-us, c-CSA-us, RCM, EAC) VH ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 (Class II, III Division 1, 2) VB ATEX/UKEX/IEC; Gas, Encapsulation, Zone 1, 2 + Dust, Protection by enclosure, Zone 20, 21/22, 21, 22 SH EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 + Dust, intrinsic safety Zone 20, 20/21, 21, 22 SB EAC/SEPRO; Gas, encapsulation, Zone 1, 2 + Dust, encapsulation Zone 21, 22 TH CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, Intrinsic safety, Zone 20, 20/21, 21, 22 (not CCOE) TB CCOE, NEPSI, KTL, TIIS; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 (not CCOE) WH INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 WB INMETRO/IA; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 FB c-FM-us/c-CSA-us; Gas, encapsulation, Zone 1, 2 (Class I Division 2) + Dust, protection by enclosure, Zone 20, 20/21, 21, 22 (Class II, III Division 1) FR c-FM-us/c-CSA-us; Gas, non-incendive, Class I Division 2 + Dust-ignition proof, Class II, III Division 1 c = Approved as overfill protection, which can be displayed as; X without W with (WHG, VLAREM) d = Ship approval, which can be displayed as; X without S with (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff / Pharmaceutical certificate, which can be displayed as: X without N with (NSF/ANSI/CAN 61) P with (NIH) F with (FDA, EG1935/2004) f = Process fitting, which can be displayed as; G Thread G1½ N Thread 1½NPT R Thread R1½ g = Cable material / length, which can be displayed as; A PUR / 5m (approx. 16ft) B PUR / 10m (approx. 32ft) H PUR / 15m (appr. 48ft) J PUR / 20m (appr. 64ft) C PUR / 25m (approx. 82ft) D PUR / individually selectable (acc. to CE, RCM, EAC) D PUR / individually selectable (acc. to c-FM-us, c-CSA-us) h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART W Four-wire Modbus S Three-wire SDI12 i = Sensor setting via smartphone and VEGA Tools app, which can be displayed as; X without B with KEY FOR VEGAPULS C 23 ab = explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, RCM, EAC) VH ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 (Class II, III Division 1, 2) VB ATEX/UKEX/IEC; Gas, Encapsulation, Zone 1, 2 + Dust, Protection by enclosure, Zone 20, 21/22, 21, 22 SH EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 + Dust, intrinsic safety Zone 20, 20/21, 21, 22 SB EAC/SEPRO; Gas, encapsulation, Zone 1, 2 + Dust, encapsulation Zone 21, 22 TH CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, Intrinsic safety, Zone 20, 20/21, 21, 22 (not CCOE) TB CCOE, NEPSI, KTL, TIIS; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 (not CCOE) WH INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 WB INMETRO/IA; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 FB c-FM-us/c-CSA-us; Gas, encapsulation, Zone 1, 2 (Class I Division 2) + Dust, protection by enclosure, Zone 20, 20/21, 21, 22 (Class II, III Division 1) FR c-FM-us/c-CSA-us; Gas, non-incendive, Class I Division 2 + Dust-ignitionproof, Class II, III Division 1 c = Approved as overfill protection, which can be displayed as; X without W with (WHG, VLAREM) d = Ship approval, which can be displayed as; X without S with (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff / Pharmaceutical certificate, which can be displayed as; X without N with (NSF/ANSI/CAN 61) P with (NIH) F with (FDA, EG1935/2004) f = Thread process side / Cable side, which can be displayed as; F Thread G1 M Thread 1NPT Q Thread R1 g = Cable material / length, which can be displayed as; A PUR / 5m (approx. 16ft) B PUR / 10m (approx. 32ft) H PUR / 15m (appr. 48ft) J PUR / 20m (appr. 64ft) C PUR / 25m (approx. 82ft) D PUR / individually selectable (acc. to CE, RCM, EAC) D PUR / individually selectable (acc. to c-FM-us, c-CSA-us) h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART W Four-wire Modbus S Three-wire SDI12 i = Sensor setting via smartphone and VEGA Tools app, which can be displayed as; X without B with KEY FOR VEGAPULS 21 / 31 ab = explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, c-FM-us, c-CSA-us, RCM, EAC) AX without, for Ex-free area (CE, UKCA, RCM) VC ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) SC EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 TC CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 WC INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 c = Approved as overfill protection, which can be displayed as; X Without W With (WHG, VLAREM) d = Ship approval, which can be displayed as; X Without S With (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff/Pharmaceutical certificate, which can be displayed as X Without N With (NSF/ANSI/CAN 61) P With (NIH) F With (FDA, EG1935/2004) f = Process fitting, which can be displayed as; G Thread G1½ N Thread 1½NPT R Thread R1½ g = Cable entry / connection, which can be displayed as; M M20x1.5 / Cable gland PA black (ø5-9mm), standard h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART i = Sensor setting via smartphone and VEGA Tools app X Without B With

Approval Holder:
VEGA Grieshaber KG
Company Name
VEGA Grieshaber KG
Address
Am Hohenstein 113 Schiltach
Postcode
77761
Country
Germany
General Email
info.de@vega.com

View All Listings by this Company
Manufacturer:
VEGA Grieshaber KG
Company Name
VEGA Grieshaber KG
Address
Am Hohenstein 113 Schiltach
Postcode
77761
Country
Germany
General Email
info.de@vega.com

View All Listings by this Company

Print This Approval


#240704008

Concealed, floor mounted basic set with DZR brass body. For use with floor standing combination tap assemblies. Maximum operating pressure 10 bar. Maximum operating temperature 70°C

Section:
1535 Miscellaneous
Section Subtitle:
Tap accessories.
WRAS Approval Number:
240704008
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (F)
Marking:
Hansgrohe & DR
Installation Requirements:
R001 R010
Expiry date:
31/07/2029
Model:
10452180

Approval Holder:
Hansgrohe SE
Company Name
Hansgrohe SE
Address
Auestrasse 5 - 9, Schiltach
Postcode
77761
Country
Germany
Phone
+49 170 4471 718
General Email
Ludovic.hauer@hansgrohe.com

View All Listings by this Company
Manufacturer:
Hansgrohe SE
Company Name
Hansgrohe SE
Address
Auestrasse 5 - 9, Schiltach
Postcode
77761
Country
Germany
Phone
+49 170 4471 718
General Email
Ludovic.hauer@hansgrohe.com

View All Listings by this Company

Print This Approval


#240702708

Range of click type pop-up wastes (brass or plastic bodies - various finishes, see model).

Section:
1535 Miscellaneous
Section Subtitle:
Tap accessories.
WRAS Approval Number:
240702708
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
1¼” BSP (M).
Marking:
ISI on body
Installation Requirements:
R001
Expiry date:
31/07/2029
Model:
Plastic body: S8803XX, B952298XX Brass body: E1482XX, B953262XX Where XX denotes finish and can be replace by: All models: AA = Chrome. B953262XX model only: A2 = Brushed Gold, A5 = Magnetic Grey, GN = Silver Storm, XG = Silk Black.

Approval Holder:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT
Country
United Kingdom
General Email
tyeomans@idealstandard.co.uk

View All Listings by this Company

Print This Approval


#240704721

Range of multistage pumps with brass impellers and stainless steel shaft, incorporating an approved check valve cartridge, however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
240704721
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
¾” BSP (M)
Marking:
Tucson, model number, product name and other technical parameters on adhesive label on terminal box; Tucson etched on pump head.
Installation Requirements:
R001 R415
Expiry date:
31/07/2029
Model:
Positive Head Twin Impeller Shower Pump SBT-2 Maximum head: 2 Bar Rated power: 0.5kW SBT-3 Maximum head: 3 Bar Rated power: 0.67kW SBT-4 Maximum head: 4 Bar Rated power: 0.9kW Positive Head Single Impeller Shower Pump SBS-3 Maximum head: 3 Bar Rated power: 0.37kW Universal Head Twin Impeller Shower Pump UBT-2 Maximum head: 2 Bar Rated power: 0.5kW UBT-3 Maximum head: 3 Bar Rated power: 0.67kW UBT-4 Maximum head: 4 Bar Rated power: 0.9kW Universal Head Single Impeller Shower Pump UBS-3 Maximum head: 3 Bar Rated power: 0.37kW

Approval Holder:
Tucson Pumps Ltd.
Company Name
Tucson Pumps Ltd.
Address
Instantor Works, Santry Avenue, Dublin, D09 K160
Country
Ireland

View All Listings by this Company

Print This Approval


#240704724

Range of single or twin shower pumps with brass bodies, brass impeller supplied with flexible connection hoses that incorporate servicing valves. Maximum Working pressure 6 Bar Maximum operating temperature 65°C

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
240704724
Size:
ROI suffix models: Stainless steel braided EPDM lined flexible hose assemblies incorporating 21mm push-fit end connections (inlet/outlet). EXP suffix models: Stainless steel braided EPDM lined flexible inlet hose assemblies incorporating ¾” captive nut end connections (inlet/outlet). OEM 44741: Monsoon U4.5 bar Single: ¾” BSP (M) (inlet/outlet) (No hose provided). All other models: Stainless steel braided EPDM lined flexible hose assemblies incorporating 22mm push-fit end connections (inlet/outlet).
Marking:
Adhesive label on body stating Stuart Turner, model no, serial no, part no, pressure rating, Monsoon, Manufacturer address and other technical information Expansion vessel labelled with volume and pressure rating
Installation Requirements:
R001
Expiry date:
31/07/2029
Model:
46505: Monsoon U1.5 bar Twin, 46498: Monsoon U2.0 bar Single, 46480: Monsoon U2.0 bar Twin, 46414: Monsoon U4.5 bar Single, 46413: Monsoon U3.0 bar Single, 46412: Monsoon U4.5 bar Twin, 46411: Monsoon U4.0 bar Twin, 46410: Monsoon U3.0 bar Twin, OEM 44741: Monsoon U4.5 bar Single, 44427: Monsoon U3.0 bar Twin, 44426: Monsoon U2.0 bar Twin, 44425: Monsoon U2.0 bar Single, OEM 44340: Monsoon U2.0 bar Twin, 44753: Monsoon U1.5 bar Twin, 46505ROI: Monsoon U1.5 bar Twin, 46498ROI: Monsoon U2.0 bar Single, 46480ROI: Monsoon U2.0 bar Twin, 46414ROI: Monsoon U4.5 bar Single, 46413ROI: Monsoon U3.0 bar Single, 46412ROI: Monsoon U4.5 bar Twin, 46411ROI: Monsoon U4.0 bar Twin, 46410ROI: Monsoon U3.0 bar Twin, 46505EXP: Monsoon U1.5 bar Twin, 46498EXP: Monsoon U2.0 bar Single, 46480EXP: Monsoon U2.0 bar Twin, 46414EXP: Monsoon U4.5 bar Single, 46413EXP: Monsoon U3.0 bar Single, 46412EXP: Monsoon U4.5 bar Twin, 46411EXP: Monsoon U4.0 bar Twin, 46410EXP: Monsoon U3.0 bar Twin.

Approval Holder:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley-on-Thames Oxfordshire
Postcode
RG9 2AD
Country
United Kingdom
Phone
01491 572655
General Email
stuart.savill@stuart-turner.co.uk

View All Listings by this Company

Print This Approval


#240707001

‘Hydro MPC’ range of booster sets incorporating vertical multistage centrifugal pumps, butterfly valves, non-return valves (not suitable for backflow protection), pressure transmitters, pressure gauges, lever operated spherical valves, stainless steel blanking flanges and fibre/NBR gaskets. Maximum working pressure 16.0 bar. Cold water use only. ‘Hydro MPC’ range of booster sets incorporating vertical multistage centrifugal pumps, butterfly valves, non-return valves (not suitable for backflow protection), pressure transmitters, pressure gauges, lever operated spherical valves, stainless steel blanking flanges and fibre/NBR gaskets. Maximum working pressure 16.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
240707001
Note:
Approval doesn’t include pressure vessels.
Size:
Small Booster Sets Systems with 2 to 3 Pumps = 2” BSP (M), Systems with 4 to 6 pumps = 2½” BSP (M). Medium Booster Sets Systems with CRI(E)10 pumps: Systems with 2 to 3 pumps = 2½” BSP (M), Systems with 4 to 5 pumps = DN80 flanges, Systems with 6 pumps = DN100 flanges. Systems with CRI(E)15 and CRI(E)20 pumps: Systems with 2 pumps = DN80 flanges, Systems with 3 to 4 pumps = DN100 flanges, Systems with 5 to 6 pumps = DN150 flanges. Sizes added November 2024: Large Booster Sets Systems with CR(E)32 pumps: Systems with 2 pumps = DN100 flanges, Systems with 3 to 6 pumps = DN150 flanges. Systems with CR(E)45 and CR(E)64 pumps: Systems with 2 pumps = DN150 flanges, Systems with 3 to 6 pumps = DN200 flanges.
Marking:
Grundfos logo, model, serial number, P/N, manufacturing country and technical information on adhesive label on base frame.
Installation Requirements:
R001 R008 R415
Expiry date:
31/07/2029
Model:
Small Booster Sets (PN16): HYDRO MPC-E “X” CRIE3, HYDRO MPC-E “X” CRIE5, HYDRO MPC-F “X” CRI3, HYDRO MPC-F “X” CRI5, HYDRO MPC-S “X” CRI3, HYDRO MPC-S “X” CRI5. Medium Booster Sets (PN16): HYDRO MPC-E “X” CRIE10, HYDRO MPC-E “X” CRIE15, HYDRO MPC-E “X” CRIE20, HYDRO MPC-F “X” CRI10, HYDRO MPC-F “X” CRI15, HYDRO MPC-F “X” CRI20, HYDRO MPC-S “X” CRI10, HYDRO MPC-S “X” CRI15, HYDRO MPC-S “X” CRI20. Models added November 2024: Large Booster Sets (PN16): HYDRO MPC-E “X” CRE32, HYDRO MPC-E “X” CRE45, HYDRO MPC-E “X” CRE64, HYDRO MPC-F “X” CR32, HYDRO MPC-F “X” CR45, HYDRO MPC-F “X” CR64, HYDRO MPC-S “X” CR32, HYDRO MPC-S “X” CR45, HYDRO MPC-S “X” CR64. The “X” preceding CR indicates the number of pumps in the booster set, between 2 and 6 pumps. The number following the pump type designation (e.g.: 32, 45 and 64) indicates the flow rate of the pump in m³/h. Full code example: Hydro MPC-E 2 CRE32-2-U2D-A-A-GHJ Where: Hydro MPC = Product name. -E = System type; All pumps with E-motor or CUE, and can also be -F for Fixed-speed pumps, 1 CUE or -S for Fixed-speed pumps. 2 = Number of pumps, this can be any number between 2 and 6. CRE = Pump type, can also be pumps beginning CR, CRI or CRIE. 3, 5, 10, 15, 20, 32, 45, 64 = flow rate of the pump in m³/h. U2 = Voltage, can also be U1, U3, U4, U5, U6, U7, U8, U9, UA, UB, UC, UD or UX. D = Design, can also be A, B, C, E, F, G, H, I or W. -A = Starting method; E (speed control). -A = Material combination; Stainless steel manifold, base frame and standard valves. -HJ = Options;, H - Dry-running protection, J - Redundant sensor.

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Country
Denmark
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval


#240802003

Range of shower handsets and overhead showers with (plastic or chrome plated plastic bodies). Open Outlet use only Maximum operating temperature 75.0°C

Section:
1650 Shower Outlets
Section Subtitle:
Shower head(s) and/or shower handset(s).
WRAS Approval Number:
240802003
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Note:
Open outlet use only.
Size:
½” BSP (M) - All other models ½” Captive nut - G50013-2C06, G07011-2C14 and G06011-2C24
Marking:
XIHE on front of body or captive nut
Installation Requirements:
R001 R040
Expiry date:
31/08/2029
Model:
S13034-2C02 S16073-2C03 S99023-2C02 S101015-2C02 S10023-2C02 S10035-2C02 S16023-2C04 S17023-2C02 S04244-2C02 G06011-2C24 G07011-2C14 G50013-2C06 S33011-2C11 S81011-2C02 S10011-2C02 S13041-2C01 S16031-1F02 Model added November 2024 S16061-2C03

Approval Holder:
Fujian Xihe Sanitary Ware Technology Co., Ltd.
Company Name
Fujian Xihe Sanitary Ware Technology Co., Ltd.
Address
High-Tech Industrial Zone, Luncang Town, Nan'An City, Fujian 362304
Country
China
Phone
+86 0595-86186107

View All Listings by this Company
Manufacturer:
Fujian Xihe Sanitary Ware Technology Co., Ltd.
Company Name
Fujian Xihe Sanitary Ware Technology Co., Ltd.
Address
High-Tech Industrial Zone, Luncang Town, Nan'An City, Fujian 362304
Country
China
Phone
+86 0595-86186107

View All Listings by this Company

Print This Approval


#240704021

Range of shower kits comprising of ABS bodied shower handsets and PVC multi-layer hoses incorporating EPDM ‘O’-rings. Supplied with riser rail. Available in various finishes. Maximum operating temperature 60°C

Section:
1650 Shower Outlets
Section Subtitle:
Shower head(s) and/or shower handset(s).
WRAS Approval Number:
240704021
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Note:
Open outlet use only.
Size:
½” BSP conical nuts
Marking:
NK (logo) on shower handset
Installation Requirements:
R001 R040
Expiry date:
31/07/2029
Model:
100303957 - Chrome 100303943 - Black 100303951 - Chrome 100303956 - Black

Approval Holder:
Noken Design S.A.U
Company Name
Noken Design S.A.U
Address
CV-20 Km2 VILA-REAL CASTELLON
Postcode
12540
Country
Spain
General Email
certificaciones@noken.com

View All Listings by this Company
Manufacturer:
Noken Design S.A.U
Company Name
Noken Design S.A.U
Address
CV-20 Km2 VILA-REAL CASTELLON
Postcode
12540
Country
Spain
General Email
certificaciones@noken.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 384 of 652

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.