Range of horizontal or vertical expansion vessels with an EPDM membrane. Maximum working pressure 10.0 or 16.0 bar (please refer to model). Maximum operating temperature 100°C.
Filling loop assemblies comprising of a stainless steel braided, EPDM lined hose, double check valve assembly with isolation valve verified by test (suitable for backflow protection against fluid category 3) and either a straight or tee isolation valve. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC.
Range of medical sterilised water filter cartridges with plastic bodies and EPDM ‘O’-Rings. Models MTFW-SLSS / MTFD-SLSS incorporate a check valve cartridge on the inlet, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum Working Temperature: 50°C.
Range of DZR brass couplings incorporating EPDM ‘O’-rings for use with Uponor Ecoflex Aqua and Uponor Ecoflex VIP Aqua PE-Xa pipe. For above and below ground use. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Tigris K5 (PPSU - plastic body) and M5 (DZR brass body) ranges of press-fit (U, H, TH crimp profiles) fittings with stainless steel crimp sleeves and EPDM ‘O’-rings, for use with Tigris K1 multi-layer PEX-c/AL/PE-HD pipe. Maximum working pressure 6.0 bar. Maximum operating temperature 95°C.
Range of copper press fittings with EPDM ‘O’-rings for use with EN1057 copper tube. The joints are achieved by means of a press tool. For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of copper press fittings with EPDM ‘O’-rings for use with EN1057 copper tube. The joints are achieved by means of a press tool. For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Instantor range of stainless-steel crimp fittings incorporating EPDM and ‘O’-rings. For use with stainless steel tube. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
Range of solder ring brass fittings for use with copper tube (manufactured to EN 1057). The HLSR20CB-d tank connector incorporates an EPDM washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘AF’ range of compression fittings with brass or chrome plated brass bodies for use with copper pipe (manufactured to EN1057). The AF14 and AF15 tap connector models incorporate an EPDM washer. Maximum working pressure 16.0 bar. Maximum working temperature 85˚C
Range of M type press fittings with TP2 copper bodies and EPDM ‘O’-rings, for use with TP2 copper pipe to EN1057. Above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘Instantor’ range of press-fit fittings incorporating DZR brass or Gunmetal bodies and EPDM ‘O’-rings for use with copper pipe (manufactured to EN1057). Maximum working pressure 16.0 bar. Maximum working temperature 95˚C.
Range of end feed brass fittings for use with copper tube (manufactured to EN 1057). The HLE20CB-d tank connector incorporates an EPDM washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘OPTIMA S’ WC dual flush outlet valve comprising of ABS plastic body, EPDM seal. The valve is operated via a dual push button for either full or reduced flush. Cold water use only
WC dual flush outlet valve comprising of ABS plastic body, EPDM gasket and an internal overflow. Cold water use only
WC dual flush outlet valve comprising of ABS plastic body, EPDM gasket and an internal overflow. Cold water use only.
‘POD’ range of indirect and direct heat interface units providing space heating and instantaneous hot water. The heat transfer is generated via plate heat exchangers. The domestic hot water (DHW) circuit incorporates an adjustable temperature mixing valve. The indirect models incorporate an expansion vessel (on the CW inlet of the DHW circuit) and a pressure relief valve set at 3.0 bar (on the space heating circuit). The indirect models only are supplied with a temporary filling loop, which comprises of a stainless steel braided EPDM lined flexible hose assembly and a lever operated spherical valve for connection to the primary circuit. The angled cold water inlet incorporates an isolation valve and a branch to connect to the filling loop, which includes a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3). Maximum working pressure for indirect units: Primary circuit: 16.0 bar. Space heating: 2.5 bar. Secondary circuit (DHW): 10.0 bar. Maximum working pressure for direct units: Primary circuit: 10.0 bar. Space heating: 10.0 bar. Secondary circuit (DHW): 10.0 bar. Maximum operating temperature for domestic hot water 65°C. Maximum operating temperature for central heating and primary circuit 85°C.
Water meter incorporating a brass body and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of compact wall outlet assemblies with plastic bodies (chromium plated) and EPDM ‘O’-rings. Maximum working pressure 5.0 bar. Maximum operating temperature 55°C.
Water control valve with a DZR brass body and EPDM ‘O’-rings. The product incorporates a pressure sensor, ultrasonic sensor, temperature sensor and a motorised spherical valve with a DZR brass ball (chrome plated) and PTFE seats. Maximum working pressure 16.0 bar. Cold water use only.
Page 36 of 109
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.