Directory Search Results

Print List

#2010387

Range of gate valves incorporating bronze bodies and wedges with PTFE seals. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.

Section:
2290 Valves
Section Subtitle:
Stop, gate, metal.
WRAS Approval Number:
2010387
Size:
½” BSP (F) - 2” BSP (F).
Marking:
OV, SIZE, DATE OF MANUFACTURE MM/YY & PN20 ON BODY. OVENTROP, PN20, WRAS and other technical information on operating member.
Installation Requirements:
R001
Expiry date:
31/10/2025
Model:
1663004, 1663006, 1663008, 1663010, 1663012 & 1663016 GATE VALVES

Approval Holder:
Oventrop GmbH & Co KG
Company Name
Oventrop GmbH & Co KG
Address
Paul-Oventrop-Strasse 1, 59939 Olsberg
Country
Germany

View All Listings by this Company

Print This Approval


#2010083

Range of gate valves with blue epoxy coated ductile iron bodies, EPDM coated ductile iron wedges. The valves operate via a non-rising spindle headwork with hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
2290 Valves
Section Subtitle:
Stop, gate, metal.
WRAS Approval Number:
2010083
Size:
DN40-400 flanged inlet/outlet.
Marking:
SIGMA FLOW COMPANY LOGO & DATE OF MANUFACTURE YYYY ON BODY
Installation Requirements:
R001
Expiry date:
31/10/2025
Model:
SIGMA FLOW RANGE OF GATE VALVES

Approval Holder:
SHI de Mexico S de RL de CV
Company Name
SHI de Mexico S de RL de CV
Postcode
ZIP CODE 44440

View All Listings by this Company

Print This Approval


#2010022

Screw down stop valve (chromium plated brass) incorporating a dome (triangular) type operating member with a NBR rubber washer. Maximum working pressure 10.0 bar. Maximum operating temperature 85.0°C

Section:
2310 Valves
Section Subtitle:
Stop, metal, screw down.
WRAS Approval Number:
2010022
Size:
½” BSP (M)
Marking:
AQUANOX on body.
Installation Requirements:
R001
Expiry date:
31/10/2025
Model:
5253
Product Images

Approval Holder:
Hydropoint
Company Name
Hydropoint

View All Listings by this Company

Print This Approval


#2010336

Range of under-counter or counter-top drinking water dispensers delivering still ambient, still chilled & sparkling water. HygienePlus®. Models incorporate a built-in filter system. The flow is controlled by a solenoid valve which is either operated by a touch or a touch pad. The water is dispensed via a tap arrangement on under-counter versions or an integrated outlet on counter-top versions. The inlets incorporate an approved check valve cartridge assembly however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Cold water use only.

Section:
2420 Water Coolers
Section Subtitle:
Drinking.
WRAS Approval Number:
2010336
Size:
¾” BSP (F).
Marking:
Brita, model and technical information on side or top body.
Installation Requirements:
R001 R150 R160 R170
Expiry date:
31/10/2025
Model:
VIVREAU Extra 50. VIVREAU Extra 50 HygienePlus®. VIVREAU Extra 85. VIVREAU Extra 85 HygienePlus®. VIVREAU Top 50. VIVREAU Top 50 HygienePlus®. VIVREAU Top 85. VIVREAU Top 85 HygienePlus®.
Product Images

Approval Holder:
Brita GmbH
Company Name
Brita GmbH
Address
Heinrich Hertz Strasse 4 D-65232 Taunusstein
Country
Germany
Phone
+49 6128 746 0
General Email
info@brita.net

View All Listings by this Company

Print This Approval


#2011519

'ABS PA-757K'. Off-white coloured, injection moulded ABS material. For use with water up to 85°C.

Section:
5020 Acrylonitrile Butadeine Styrene Copolymer (ABS)
Expiry date:
30/11/2025

Approval Holder:
Zhenjiang Chimei Chemical Co. Ltd.
Company Name
Zhenjiang Chimei Chemical Co. Ltd.
Address
No. 88 Hanqiao Road, Zhenjiang New Area, Jiangsu
Country
China

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 27 of 1576

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.